Improving MCE with electrochemical detection using a bubble cell and sample stacking techniques
- 2 October 2009
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 30 (19) , 3339-3346
Abstract
Two efforts to improve the sensitivity and limits of detection for MCE with electrochemical detection are presented here. One is the implementation of a capillary expansion (bubble cell) at the detection zone to increase the exposed working electrode surface area. Bubble cell widths were varied from 1× to 10× the separation channel width (50 μm) to investigate the effects of electrode surface area on detection sensitivity, LOD, and separation efficiency. Improved detection sensitivity and decreased detection limits were obtained with increased bubble cell width, and LODs of dopamine and catechol detected in a 5× bubble cell were 25 and 50 nM, respectively. Meanwhile, fluorescent imaging results demonstrated ∼8 and ∼12% loss in separation efficiency in 4× and 5× bubble cell, respectively. Another effort at reducing the LOD involves using field amplified sample injection for gated injection and field amplified sample stacking for hydrodynamic injection. Stacking effects are shown for both methods using amperometric detection and pulsed amperometric detection. The LODs of dopamine in a 4× bubble cell were 8 and 20 nM using field amplified sample injection and field amplified sample stacking, respectively. However, improved LODs were not obtained for anionic analytes using either stacking technique.Keywords
This publication has 70 references indexed in Scilit:
- Electrode array detector for microchip capillary electrophoresisThe Analyst, 2008
- Recent progress of online sample preconcentration techniques in microchip electrophoresisJournal of Separation Science, 2008
- Study of injection bias in a simple hydrodynamic injection in microchip CEElectrophoresis, 2007
- Ultraviolet absorbance detection of colchicine and related alkaloids on a capillary electrophoresis microchipAnalytica Chimica Acta, 2006
- On-Line Sample Preconcentration Using Field-amplified Stacking Injection in Microchip Capillary ElectrophoresisAnalytical Chemistry, 2006
- A disposable capillary electrophoresis microchip with an indium tin oxide decoupler/amperometric detectorMicroelectronic Engineering, 2005
- Micro Total Analysis Systems. Recent DevelopmentsAnalytical Chemistry, 2004
- Versatile 3-channel high-voltage power supply for microchip capillary electrophoresisLab on a Chip, 2003
- Determination of mono- and disaccharides in milk and milk products by high-performance anion-exchange chromatography with pulsed amperometric detectionAnalytica Chimica Acta, 2003
- Mechanism of Peptide Separations by Solid Phase Extraction Capillary Electrophoresis at Low pHAnalytical Chemistry, 1996