Rapid Determination of Non-steroidal Anti-inflammatory Drugs in Aquatic Matrices by Two-phase Micro-electrodriven Membrane Extraction Combined with Liquid Chromatography
- 24 October 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 56 (2) , 166-176
Abstract
Two-phase micro-electrodriven membrane extraction (EME) procedure for the pre-concentration of selected non-steroidal anti-inflammatory drugs (NSAIDs) in aquatic matrices was investigated. Agarose film was used as interface between donor and acceptor phase in EME which allowed for selective extraction of the analytes prior to high performance liquid chromatography-ultraviolet detection. Charged analytes were transported from basic aqueous sample solution through agarose film into 1-octanol as an acceptor phase at 9 V potential. Response surface methodology in conjunction with the central composite design showed good correlations between extraction time and applied voltage (R2 > 0.9358). Under optimized extraction conditions, the method showed good linearity in the concentration range of 0.5–500 μg L–1 with coefficients of determination, r2≥ 0.9942 and good limits of detection (0.14–0.42 μg L–1) and limits of quantification (0.52–1.21 μg L–1). The results also showed high enrichment factors (62–86) and good relative recoveries (72–114%) with acceptable reproducibilities (RSDs ≤ 7.5% n = 3). The method was successfully applied to the determination of NSAIDs from tap water and river water samples. The proposed method proved to be rapid, simple and requires low voltage and minute amounts of organic solvent, thus environmentally friendly.Keywords
This publication has 44 references indexed in Scilit:
- Recent developments in electromembrane extractionAnalytical Methods, 2013
- Electromembrane extraction of peptides – Fundamental studies on the supported liquid membraneJournal of Separation Science, 2011
- Determination of thebaine in water samples, biological fluids, poppy capsule, and narcotic drugs, using electromembrane extraction followed by high-performance liquid chromatography analysisAnalytica Chimica Acta, 2011
- Microextraction of mebendazole across supported liquid membrane forced by pH gradient and electrical fieldJournal of Pharmaceutical and Biomedical Analysis, 2011
- Electromembrane extraction of heavy metal cations followed by capillary electrophoresis with capacitively coupled contactless conductivity detectionElectrophoresis, 2011
- Optimization of preparation conditions for mangosteen peel-based activated carbons for the removal of Remazol Brilliant Blue R using response surface methodologyChemical Engineering Journal, 2010
- Electro membrane extraction combined with capillary electrophoresis for the determination of amlodipine enantiomers in biological samplesJournal of Separation Science, 2010
- HPLC determination of ibuprofen, diclofenac and salicylic acid using hollow fiber-based liquid phase microextraction (HF-LPME)Analytica Chimica Acta, 2009
- Response surface methodology (RSM) as a tool for optimization in analytical chemistryTalanta, 2008
- Determination of metacrate in water samples using dispersive liquid–liquid microextraction and HPLC with the aid of response surface methodology and experimental designAnalytica Chimica Acta, 2008