Mohd Marsin Sanagi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohd Marsin Sanagi has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
Wan Aini Wan Ibrahim
Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia; Centre for Sustainable Nanomaterials, Ibnu Sina Institute for Scientific and Industrial Research, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
30 shared publicationsAhmedy Abu Naim
Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
9 shared publications- Wan Aini Wan Ibrahim
Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, Johor Bahru, Malaysia
9 shared publications - Hassan Youssef Aboul-Enein
Pharmaceutical and Medicinal Chemistry Department, Pharmaceutical and Drug Industries Research Division, National Research Center, Cairo 12622, Egypt
8 shared publications - Noorfatimah Yahaya
Universiti Sains Malaysia
7 shared publications Khairil Juhanni Abd Karim
Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
5 shared publications
Latest Publications
- 1 March 2021
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 174, 216-228
Alginate-based adsorbents for removal of metal ions and radionuclides from aqueous solutions: A review
- 1 March 2021
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 174, 216-228
Alginate-based adsorbents for removal of metal ions and radionuclides from aqueous solutions: A review
- 1 June 2020
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 153, 513-522
New efficient chitosan derivative for Cu(II) ions removal: Characterization and adsorption performance
- 1 June 2020
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 153, 513-522
New efficient chitosan derivative for Cu(II) ions removal: Characterization and adsorption performance
- 1 July 2019
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 133, 1260-1267
Enhanced removal of Orange G from aqueous solutions by modified chitosan beads: Performance and mechanism
- 1 July 2019
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 133, 1260-1267
Enhanced removal of Orange G from aqueous solutions by modified chitosan beads: Performance and mechanism
- 1 September 2018
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 116, 255-263
Equilibrium, kinetic and mechanism studies of Cu(II) and Cd(II) ions adsorption by modified chitosan beads
- 1 September 2018
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 116, 255-263
Equilibrium, kinetic and mechanism studies of Cu(II) and Cd(II) ions adsorption by modified chitosan beads
- 1 July 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (14) , 2942-2951
Solid‐phase microextraction based on an agarose‐chitosan‐multiwalled carbon nanotube composite film combined with HPLC–UV for the determination of nonsteroidal anti‐inflammatory drugs in aqueous samples
We describe the preparation, characterization, and application of a composite film adsorbent based on blended agarose‐chitosan‐multiwalled carbon nanotubes for the preconcentration of selected nonsteroidal anti‐inflammatory drugs in aqueous samples before determination by high performance liquid chromatography with ultraviolet detection. The composite film showed a high surface area (4.0258 m2/g) and strong hydrogen bonding between the multiwalled carbon nanotubes and agarose/chitosan matrix, which prevent adsorbent deactivation and ensure long‐term stability. Several parameters, such as sample pH, addition of salt, extraction time, desorption solvent, and concentration of multiwalled carbon nanotubes in the composite film were optimized using a one‐factor‐at‐time approach. The optimum extraction conditions obtained were as follows: isopropanol as conditioning solvent, 10 mL of sample solution at pH 2, extraction time of 30 min, stirring speed of 600 rpm, 100 μL of isopropanol as desorption solvent, desorption time of 5 min under ultrasonication, and 0.4% w/v of composite film. Under the optimized conditions, the calibration curve showed good linearity in the range of 1–500 ng/mL (r2 = 0.997–0.999), and good limits of detection (0.89–8.05 ng/mL) were obtained with good relative standard deviations of < 4.59% (n = 3) for the determination of naproxen, diclofenac sodium salt, and mefenamic acid drugs.
- 1 July 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (14) , 2942-2951
Solid‐phase microextraction based on an agarose‐chitosan‐multiwalled carbon nanotube composite film combined with HPLC–UV for the determination of nonsteroidal anti‐inflammatory drugs in aqueous samples
We describe the preparation, characterization, and application of a composite film adsorbent based on blended agarose‐chitosan‐multiwalled carbon nanotubes for the preconcentration of selected nonsteroidal anti‐inflammatory drugs in aqueous samples before determination by high performance liquid chromatography with ultraviolet detection. The composite film showed a high surface area (4.0258 m2/g) and strong hydrogen bonding between the multiwalled carbon nanotubes and agarose/chitosan matrix, which prevent adsorbent deactivation and ensure long‐term stability. Several parameters, such as sample pH, addition of salt, extraction time, desorption solvent, and concentration of multiwalled carbon nanotubes in the composite film were optimized using a one‐factor‐at‐time approach. The optimum extraction conditions obtained were as follows: isopropanol as conditioning solvent, 10 mL of sample solution at pH 2, extraction time of 30 min, stirring speed of 600 rpm, 100 μL of isopropanol as desorption solvent, desorption time of 5 min under ultrasonication, and 0.4% w/v of composite film. Under the optimized conditions, the calibration curve showed good linearity in the range of 1–500 ng/mL (r2 = 0.997–0.999), and good limits of detection (0.89–8.05 ng/mL) were obtained with good relative standard deviations of < 4.59% (n = 3) for the determination of naproxen, diclofenac sodium salt, and mefenamic acid drugs.
- 1 February 2018
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 107, 891-897
New crosslinked-chitosan graft poly(N-vinyl-2-pyrrolidone) for the removal of Cu(II) ions from aqueous solutions
- 1 February 2018
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 107, 891-897
New crosslinked-chitosan graft poly(N-vinyl-2-pyrrolidone) for the removal of Cu(II) ions from aqueous solutions
- 24 October 2017
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 56 (2) , 166-176
Rapid Determination of Non-steroidal Anti-inflammatory Drugs in Aquatic Matrices by Two-phase Micro-electrodriven Membrane Extraction Combined with Liquid Chromatography
Two-phase micro-electrodriven membrane extraction (EME) procedure for the pre-concentration of selected non-steroidal anti-inflammatory drugs (NSAIDs) in aquatic matrices was investigated. Agarose film was used as interface between donor and acceptor phase in EME which allowed for selective extraction of the analytes prior to high performance liquid chromatography-ultraviolet detection. Charged analytes were transported from basic aqueous sample solution through agarose film into 1-octanol as an acceptor phase at 9 V potential. Response surface methodology in conjunction with the central composite design showed good correlations between extraction time and applied voltage (R2 > 0.9358). Under optimized extraction conditions, the method showed good linearity in the concentration range of 0.5–500 μg L–1 with coefficients of determination, r2≥ 0.9942 and good limits of detection (0.14–0.42 μg L–1) and limits of quantification (0.52–1.21 μg L–1). The results also showed high enrichment factors (62–86) and good relative recoveries (72–114%) with acceptable reproducibilities (RSDs ≤ 7.5% n = 3). The method was successfully applied to the determination of NSAIDs from tap water and river water samples. The proposed method proved to be rapid, simple and requires low voltage and minute amounts of organic solvent, thus environmentally friendly.
- 24 October 2017
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 56 (2) , 166-176
Rapid Determination of Non-steroidal Anti-inflammatory Drugs in Aquatic Matrices by Two-phase Micro-electrodriven Membrane Extraction Combined with Liquid Chromatography
Two-phase micro-electrodriven membrane extraction (EME) procedure for the pre-concentration of selected non-steroidal anti-inflammatory drugs (NSAIDs) in aquatic matrices was investigated. Agarose film was used as interface between donor and acceptor phase in EME which allowed for selective extraction of the analytes prior to high performance liquid chromatography-ultraviolet detection. Charged analytes were transported from basic aqueous sample solution through agarose film into 1-octanol as an acceptor phase at 9 V potential. Response surface methodology in conjunction with the central composite design showed good correlations between extraction time and applied voltage (R2 > 0.9358). Under optimized extraction conditions, the method showed good linearity in the concentration range of 0.5–500 μg L–1 with coefficients of determination, r2≥ 0.9942 and good limits of detection (0.14–0.42 μg L–1) and limits of quantification (0.52–1.21 μg L–1). The results also showed high enrichment factors (62–86) and good relative recoveries (72–114%) with acceptable reproducibilities (RSDs ≤ 7.5% n = 3). The method was successfully applied to the determination of NSAIDs from tap water and river water samples. The proposed method proved to be rapid, simple and requires low voltage and minute amounts of organic solvent, thus environmentally friendly.
- 4 October 2016
- Published by Springer Nature in Applied Physics A
- Vol. 122 (10) , 935
Mesoporous nanocomposite coatings for photonic devices: sol–gel approach
- 4 October 2016
- Published by Springer Nature in Applied Physics A
- Vol. 122 (10) , 935
Mesoporous nanocomposite coatings for photonic devices: sol–gel approach