Safety and efficacy of applying a low-dose radiation fluoroscopy protocol in device implantations
Open Access
- 4 October 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 19 (8) , 1364-1368
Abstract
For cardiac implantable electronic device (CIED) implantations, visualization of lead placement is necessary and fluoroscopy remains by far the most commonly used technique. With simple changes in the X-ray system settings, total radiation dose can be reduced significantly. The purpose of this study was to assess the safety and efficacy of various CIED implantations performed after implementation of a new dose reduction protocol (DRP). We conducted a retrospective chart review of 584 patients undergoing CIED implantation or revision in our hospital. Of these patients, 280 (48%) underwent the implantation prior to and 304 (52%) after the DRP introduction. The DRP included various changes for optimized image processing and exposure system settings to enable dose reduction, as well as a reduced frame rates (4 FPS for fluoroscopy and 7.5 FPS for cinematographic images). Of the 584 patients, 53 (9.1%) had a one-chamber pacemaker, 232 (39.7%) a two-chamber pacemaker, 133 (22.8%) a one-chamber ICD, 35 (6.0%) a two-chamber ICD, 82 (14.0%) a CRT ( de novo ) implantation, and 49 (8.3%) had an upgrade to a CRT device. DRP was associated with a 64% reduction of the dose-area product (1372 ± 2659 vs. 3792 ± 5025 cGcm 2 , P < 0.001), while fluoroscopy duration (13 ± 15 vs. 13 ± 15 min) and procedural duration (93 ± 52 vs. 92 ± 52 min.) did not significantly increase. Complication rates did not differ significantly between the two groups. The DRP proved to effectively reduce radiation dose for all types of CIED implantations. Fluoroscopy time, total procedure time, and the number of complications did not increase after introducing the DRP.Keywords
This publication has 12 references indexed in Scilit:
- Reduction of radiation exposure in catheter ablation of atrial fibrillation: Lesson learnedWorld Journal of Cardiology, 2015
- Reducing Radiation Exposure in the Electrophysiology Laboratory: It is More Than Just Fluoroscopy Times!Pacing and Clinical Electrophysiology, 2014
- Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological proceduresEP Europace, 2014
- Radiation Dose Reduction in the Cardiac Catheterization Laboratory Utilizing a Novel ProtocolJACC: Cardiovascular Interventions, 2014
- Non-fluoroscopic catheter visualization using MediGuide™ technology: experience from the first 600 proceduresJournal of Interventional Cardiac Electrophysiology, 2014
- Brain and Neck Tumors Among Physicians Performing Interventional ProceduresThe American Journal of Cardiology, 2013
- Obesity Is a Major Determinant of Radiation Dose in Patients Undergoing Pulmonary Vein Isolation for Atrial FibrillationJACC, 2007
- ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular proceduresJACC, 2004
- Informed consent and communication of risk from radiological and nuclear medicine examinations: how to escape from a communication infernoBMJ, 2004
- X-ray dose and associated risks from radiofrequency catheter ablation proceduresBritish Journal of Radiology, 2002