Abstract
We present an electrical analysis method for a gamma-ray imaging system based on a resistive network readout. Currently, the array numbers of scintillators and detectors in imaging systems are being increased to enhance the spatial resolution, and resistive network based readout circuits are used to reduce the number of channels. However, a positioning process is required to identify the channel in which the signal has been generated, which causes positional distortion. For position correction, the positioning characteristics must be measured according to the readout circuit conditions. However, owing to the scintillator’s radiation, measurement in a single channel is difficult. In this work, a current pulse is modeled to analyze the positional characteristics of different channels. A current pulse generator and an automatic channel-selection circuit are designed to input signals selectively to each channel. When the input signal duration is 1 μs, the maximum amount of charge generated by the current pulse generator is approximately 1000 pC. Position errors of up to 88.47% are generated, depending on the gain of the preamplifier. Our proposed method can be used for the linearity analysis of preamplifiers and image position correction algorithms.Keywords
Funding Information
- National Research Foundation of Korea
- Ministry of Education through the Basic Science Research Program (NRF-2018R1D1A1B07048145)
- Chung-Ang University Graduate Research Scholarship in 2020
This publication has 23 references indexed in Scilit:
- Compton imaging with 99mTc for human imagingScientific Reports, 2019
- Secondary Electron Emission Materials for Transmission Dynodes in Novel Photomultipliers: A ReviewMaterials, 2016
- Position Error Correction Using Homography in Discretized Positioning Circuit for Gamma-Ray Imaging Detection SystemIEEE Transactions on Nuclear Science, 2016
- Development of Compton imaging system for nuclear material monitoring at pyroprocessing test-bed facilityJournal of Nuclear Science and Technology, 2016
- Scintillation response of Xe gas studied by gamma-ray absorption and Compton electronsJournal of Instrumentation, 2015
- Low Statistics Reconstruction of the Compton Camera Point Spread Function in 3D Prompt-$\gamma$ Imaging of Ion Beam TherapyIEEE Transactions on Nuclear Science, 2013
- Design and Performance of a Resistor Multiplexing Readout Circuit for a SiPM DetectorIEEE Transactions on Nuclear Science, 2013
- Design and development of compact readout electronics with silicon photomultiplier array for a compact imaging detectorChinese Physics C, 2012
- An efficient detector production method for position-sensitive scintillation detector arrays with 98% detector packing fractionIEEE Transactions on Nuclear Science, 2003
- An electronically collimated gamma camera for single photon emission computed tomography. Part I: Theoretical considerations and design criteriaMedical Physics, 1983