Tiny golden angle ultrashort echo‐time lung imaging in mice
Open Access
- 28 July 2021
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (11) , e4591
Abstract
Imaging the lung parenchyma with MRI is particularly difficult in small animals due to the high respiratory and heart rates, and ultrashort T2* at high magnetic field strength caused by the high susceptibilities induced by the air–tissue interfaces. In this study, a 2D ultrashort echo‐time (UTE) technique was combined with tiny golden angle (tyGA) ordering. Data were acquired continuously at 11.7 T and retrospective center‐of‐k‐space gating was applied to reconstruct respiratory multistage images. Lung (proton) density (fP), T2*, signal‐to‐noise ratio (SNR), fractional ventilation (FV) and perfusion (f) were quantified, and the application to dynamic contrast agent (CA)‐enhanced (DCE) qualitative perfusion assessment tested. The interobserver and intraobserver and interstudy reproducibility of the quantitative parameters were investigated. High‐quality images of the lung parenchyma could be acquired in all animals. Over all lung regions a mean T2* of 0.20 ± 0.05 ms was observed. FV resulted as 0.31 ± 0.13, and a trend towards lower SNR values during inspiration (EX: SNR = 12.48 ± 6.68, IN: SNR = 11.79 ± 5.86) and a significant (P < 0.001) decrease in lung density (EX: fP = 0.69 ± 0.13, IN: fP = 0.62 ± 0.13) were observed. Quantitative perfusion results as 34.63 ± 9.05 mL/cm3/min (systole) and 32.77 ± 8.55 mL/cm3/min (diastole) on average. The CA dynamics could be assessed and, because of the continuous nature of the data acquisition, reconstructed at different temporal resolutions. Where a good to excellent interobserver reproducibility and an excellent intraobserver reproducibility resulted, the interstudy reproducibility was only fair to good. In conclusion, the combination of tiny golden angles with UTE (2D tyGA UTE) resulted in a reliable imaging technique for lung morphology and function in mice, providing uniform k‐space coverage and thus low‐artefact images of the lung parenchyma after gating.Keywords
Funding Information
- Universität Ulm (465599659)
This publication has 56 references indexed in Scilit:
- Quantitative lung perfusion evaluation using fourier decomposition perfusion MRIMagnetic Resonance in Medicine, 2013
- DC‐gated high resolution three‐dimensional lung imaging during free‐breathingJournal of Magnetic Resonance Imaging, 2012
- MRI of the lung (1/3): methodsInsights into Imaging, 2012
- Quantitative monitoring of mouse lung tumors by magnetic resonance imagingNature Protocols, 2012
- A constant‐volume ventilator and gas recapture system for hyperpolarized gas MRI of mouse and rat lungsConcepts in Magnetic Resonance Part B, 2011
- Lung perfusion measured using magnetic resonance imaging: New tools for physiological insights into the pulmonary circulationJournal of Magnetic Resonance Imaging, 2010
- Pulmonary Abnormalities in Mice with Paracoccidioidomycosis: A Sequential Study Comparing High Resolution Computed Tomography and Pathologic FindingsPLOS Neglected Tropical Diseases, 2010
- Validation of simple and robust protocols for high‐resolution lung proton MRI in miceMagnetic Resonance in Medicine, 2010
- Pulmonary perfusion imaging in the rodent lung using dynamic contrast‐enhanced MRIMagnetic Resonance in Medicine, 2008
- Whole‐heart coronary vein imaging: A comparison between non‐contrast‐agent‐ and contrast‐agent‐enhanced visualization of the coronary venous systemMagnetic Resonance in Medicine, 2007