Hao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hao Li has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Volker Rasche
Department of Internal Medicine II, Ulm University Medical Center, Ulm, Germany
8 shared publications - Patrick Metze
Department of Internal Medicine II, Ulm University Medical Center, Ulm, Germany
4 shared publications - Alireza Abaei
Core Facility Small Animal Imaging (CF-SANI), Ulm University, Ulm, Germany
3 shared publications - Dominik Buckert
Department of Internal Medicine II, University Medical Center, 89081 Ulm, Germany
3 shared publications - Wolfgang Rottbauer
Ulm University Heart Center
3 shared publications Patrick Metze
Department of Internal Medicine II Ulm University Medical Center Ulm Germany
2 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (11) , e70418
Radial Tiny Golden Angle UTE (tyGA‐UTE) for Cardiac MRI in the Small Animal Model
Robust cardiorespiratory motion correction is critical for high‐quality ultra‐high‐field (UHF) preclinical cardiac magnetic resonance imaging (MRI). Whereas radial tiny golden angle (tyGA) sampling, data‐driven self‐gating (sg), compressed sensing (CS), and ultrashort echo time (UTE) are individually well‐established techniques, their integration into a unified acquisition and reconstruction pipeline, together with systematic validation at 11.7 T remains insufficiently explored. This study presents and validates a UHF‐optimized tyGA‐based UTE workflow that enables high‐temporal‐resolution sliding‐window dynamic imaging (SW‐tyGA‐UTE) and high‐spatial‐resolution cardiorespiratory self‐gated cine imaging (Gated‐tyGA‐UTE) from a single continuous acquired tyGA acquisition. All experiments were performed on an 11.7‐T small‐animal MRI system in 16 healthy wild‐type mice. Cardiac functional parameters, image quality metrics (signal‐to‐noise ratio [SNR] and contrast‐to‐noise ratio [CNR]), and inter‐/intra‐observer reproducibility were systematically compared between the proposed tyGA‐UTE pipeline and two navigator‐gated reference techniques: retrospectively gated FLASH and UTE methodologies. SW‐tyGA‐UTE and Gated‐tyGA‐UTE reconstructions yielded global left ventricular functional parameters comparable to those obtained with the reference methods (all p > 0.05). All functional metrics showed excellent intra‐observer (ICC = 0.94–0.99) and inter‐observer (ICC = 0.90–0.98) reproducibility, with ejection fraction showing the highest measurement consistency. Image quality was evaluated using an image‐based within‐ROI noise quantification approach that captures both thermal noise and reconstruction‐related artifacts. In this analysis, the Gated‐tyGA‐UTE protocol showed no statistically significant differences in left ventricular blood‐pool SNR, myocardial SNR, or CNR relative to the reference sequences. In contrast, the high‐temporal‐resolution sliding‐window reconstruction showed significantly reduced image quality across all three metrics, consistent with the expected spatiotemporal trade‐off of undersampled dynamic imaging. This study validates a robust, UHF‐optimized tyGA‐UTE imaging workflow that generates both high‐fidelity quantitative cine data and ultra‐fast dynamic cardiac images from a single acquisition. The unified pipeline eliminates the need for sequential repeated scans, minimizes anesthesia‐related physiological variability, and improves experimental efficiency, providing a practical tool for preclinical cardiac phenotyping, longitudinal studies, and drug screening.
- 14 October 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (11) , e70418
Open AccessRadial Tiny Golden Angle UTE (tyGA‐UTE) for Cardiac MRI in the Small Animal Model
Robust cardiorespiratory motion correction is critical for high‐quality ultra‐high‐field (UHF) preclinical cardiac magnetic resonance imaging (MRI). Whereas radial tiny golden angle (tyGA) sampling, data‐driven self‐gating (sg), compressed sensing (CS), and ultrashort echo time (UTE) are individually well‐established techniques, their integration into a unified acquisition and reconstruction pipeline, together with systematic validation at 11.7 T remains insufficiently explored. This study presents and validates a UHF‐optimized tyGA‐based UTE workflow that enables high‐temporal‐resolution sliding‐window dynamic imaging (SW‐tyGA‐UTE) and high‐spatial‐resolution cardiorespiratory self‐gated cine imaging (Gated‐tyGA‐UTE) from a single continuous acquired tyGA acquisition. All experiments were performed on an 11.7‐T small‐animal MRI system in 16 healthy wild‐type mice. Cardiac functional parameters, image quality metrics (signal‐to‐noise ratio [SNR] and contrast‐to‐noise ratio [CNR]), and inter‐/intra‐observer reproducibility were systematically compared between the proposed tyGA‐UTE pipeline and two navigator‐gated reference techniques: retrospectively gated FLASH and UTE methodologies. SW‐tyGA‐UTE and Gated‐tyGA‐UTE reconstructions yielded global left ventricular functional parameters comparable to those obtained with the reference methods (all p > 0.05). All functional metrics showed excellent intra‐observer (ICC = 0.94–0.99) and inter‐observer (ICC = 0.90–0.98) reproducibility, with ejection fraction showing the highest measurement consistency. Image quality was evaluated using an image‐based within‐ROI noise quantification approach that captures both thermal noise and reconstruction‐related artifacts. In this analysis, the Gated‐tyGA‐UTE protocol showed no statistically significant differences in left ventricular blood‐pool SNR, myocardial SNR, or CNR relative to the reference sequences. In contrast, the high‐temporal‐resolution sliding‐window reconstruction showed significantly reduced image quality across all three metrics, consistent with the expected spatiotemporal trade‐off of undersampled dynamic imaging. This study validates a robust, UHF‐optimized tyGA‐UTE imaging workflow that generates both high‐fidelity quantitative cine data and ultra‐fast dynamic cardiac images from a single acquisition. The unified pipeline eliminates the need for sequential repeated scans, minimizes anesthesia‐related physiological variability, and improves experimental efficiency, providing a practical tool for preclinical cardiac phenotyping, longitudinal studies, and drug screening.
- Open Access
- 8 April 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (8) , 2088
Real-Time Spiral CMR Is Superior to Conventional Segmented Cine-Imaging for Left-Ventricular Functional Assessment in Patients with Arrhythmia
(1) Background: Segmented Cartesian Cardiovascular magnetic resonance (CMR) often fails to deliver robust assessment of cardiac function in patients with arrhythmia. We aimed to assess the performance of a tiny golden-angle spiral real-time CMR sequence at 1.5 T for left-ventricular (LV) volumetry in patients with irregular heart rhythm; (2) Methods: We validated the real-time sequence against the standard breath-hold segmented Cartesian sequence in 32 patients, of whom 11 presented with arrhythmia. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were assessed. In arrhythmic patients, real-time and standard Cartesian acquisitions were compared against a reference echocardiographic modality; (3) Results: In patients with sinus rhythm, good agreements and correlations were found between the segmented and real-time methods, with only minor, non-significant underestimation of EDV for the real-time sequence (135.95 ± 30 mL vs. 137.15 ± 31, p = 0.164). In patients with arrhythmia, spiral real-time CMR yielded superior image quality to the conventional segmented imaging, allowing for excellent agreement with the reference echocardiographic volumetry. In contrast, in this cohort, standard Cartesian CMR showed significant underestimation of LV-ESV (106.72 ± 63.51 mL vs. 125.47 ± 72.41 mL, p = 0.026) and overestimation of LVEF (42.96 ± 10.81% vs. 39.02 ± 11.72%, p = 0.039); (4) Conclusions: Real-time spiral CMR improves image quality in arrhythmic patients, allowing reliable assessment of LV volumetry.
- 8 April 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (8) , 2088
Open AccessReal-Time Spiral CMR Is Superior to Conventional Segmented Cine-Imaging for Left-Ventricular Functional Assessment in Patients with Arrhythmia
(1) Background: Segmented Cartesian Cardiovascular magnetic resonance (CMR) often fails to deliver robust assessment of cardiac function in patients with arrhythmia. We aimed to assess the performance of a tiny golden-angle spiral real-time CMR sequence at 1.5 T for left-ventricular (LV) volumetry in patients with irregular heart rhythm; (2) Methods: We validated the real-time sequence against the standard breath-hold segmented Cartesian sequence in 32 patients, of whom 11 presented with arrhythmia. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were assessed. In arrhythmic patients, real-time and standard Cartesian acquisitions were compared against a reference echocardiographic modality; (3) Results: In patients with sinus rhythm, good agreements and correlations were found between the segmented and real-time methods, with only minor, non-significant underestimation of EDV for the real-time sequence (135.95 ± 30 mL vs. 137.15 ± 31, p = 0.164). In patients with arrhythmia, spiral real-time CMR yielded superior image quality to the conventional segmented imaging, allowing for excellent agreement with the reference echocardiographic volumetry. In contrast, in this cohort, standard Cartesian CMR showed significant underestimation of LV-ESV (106.72 ± 63.51 mL vs. 125.47 ± 72.41 mL, p = 0.026) and overestimation of LVEF (42.96 ± 10.81% vs. 39.02 ± 11.72%, p = 0.039); (4) Conclusions: Real-time spiral CMR improves image quality in arrhythmic patients, allowing reliable assessment of LV volumetry.
- Open Access
- 28 July 2021
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (11) , e4591
Tiny golden angle ultrashort echo‐time lung imaging in mice
Imaging the lung parenchyma with MRI is particularly difficult in small animals due to the high respiratory and heart rates, and ultrashort T2* at high magnetic field strength caused by the high susceptibilities induced by the air–tissue interfaces. In this study, a 2D ultrashort echo‐time (UTE) technique was combined with tiny golden angle (tyGA) ordering. Data were acquired continuously at 11.7 T and retrospective center‐of‐k‐space gating was applied to reconstruct respiratory multistage images. Lung (proton) density (fP), T2*, signal‐to‐noise ratio (SNR), fractional ventilation (FV) and perfusion (f) were quantified, and the application to dynamic contrast agent (CA)‐enhanced (DCE) qualitative perfusion assessment tested. The interobserver and intraobserver and interstudy reproducibility of the quantitative parameters were investigated. High‐quality images of the lung parenchyma could be acquired in all animals. Over all lung regions a mean T2* of 0.20 ± 0.05 ms was observed. FV resulted as 0.31 ± 0.13, and a trend towards lower SNR values during inspiration (EX: SNR = 12.48 ± 6.68, IN: SNR = 11.79 ± 5.86) and a significant (P < 0.001) decrease in lung density (EX: fP = 0.69 ± 0.13, IN: fP = 0.62 ± 0.13) were observed. Quantitative perfusion results as 34.63 ± 9.05 mL/cm3/min (systole) and 32.77 ± 8.55 mL/cm3/min (diastole) on average. The CA dynamics could be assessed and, because of the continuous nature of the data acquisition, reconstructed at different temporal resolutions. Where a good to excellent interobserver reproducibility and an excellent intraobserver reproducibility resulted, the interstudy reproducibility was only fair to good. In conclusion, the combination of tiny golden angles with UTE (2D tyGA UTE) resulted in a reliable imaging technique for lung morphology and function in mice, providing uniform k‐space coverage and thus low‐artefact images of the lung parenchyma after gating.
- 28 July 2021
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (11) , e4591
Open AccessTiny golden angle ultrashort echo‐time lung imaging in mice
Imaging the lung parenchyma with MRI is particularly difficult in small animals due to the high respiratory and heart rates, and ultrashort T2* at high magnetic field strength caused by the high susceptibilities induced by the air–tissue interfaces. In this study, a 2D ultrashort echo‐time (UTE) technique was combined with tiny golden angle (tyGA) ordering. Data were acquired continuously at 11.7 T and retrospective center‐of‐k‐space gating was applied to reconstruct respiratory multistage images. Lung (proton) density (fP), T2*, signal‐to‐noise ratio (SNR), fractional ventilation (FV) and perfusion (f) were quantified, and the application to dynamic contrast agent (CA)‐enhanced (DCE) qualitative perfusion assessment tested. The interobserver and intraobserver and interstudy reproducibility of the quantitative parameters were investigated. High‐quality images of the lung parenchyma could be acquired in all animals. Over all lung regions a mean T2* of 0.20 ± 0.05 ms was observed. FV resulted as 0.31 ± 0.13, and a trend towards lower SNR values during inspiration (EX: SNR = 12.48 ± 6.68, IN: SNR = 11.79 ± 5.86) and a significant (P < 0.001) decrease in lung density (EX: fP = 0.69 ± 0.13, IN: fP = 0.62 ± 0.13) were observed. Quantitative perfusion results as 34.63 ± 9.05 mL/cm3/min (systole) and 32.77 ± 8.55 mL/cm3/min (diastole) on average. The CA dynamics could be assessed and, because of the continuous nature of the data acquisition, reconstructed at different temporal resolutions. Where a good to excellent interobserver reproducibility and an excellent intraobserver reproducibility resulted, the interstudy reproducibility was only fair to good. In conclusion, the combination of tiny golden angles with UTE (2D tyGA UTE) resulted in a reliable imaging technique for lung morphology and function in mice, providing uniform k‐space coverage and thus low‐artefact images of the lung parenchyma after gating.
- Open Access
- 23 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Quantification of Biventricular Myocardial Strain Using CMR Feature Tracking: Reproducibility in Small Animals
Myocardial strain is a well‐validated parameter for evaluating myocardial contraction. Cardiovascular magnetic resonance myocardial feature tracking (CMR‐FT) is a novel method for the quantitative measurements of myocardial strain from routine cine acquisitions. In this study, we investigated the influence of temporal resolution on tracking accuracy of CMR‐FT and the intraobserver, interobserver, and interstudy reproducibilities for biventricular strain analysis in mice from self‐gated CMR at 11.7 T. 12 constitutive nexilin knockout (Nexn‐KO) mice, heterozygous (Het, N = 6) and wild‐type (WT, N = 6), were measured with a well‐established self‐gating sequence twice within two weeks. CMR‐FT measures of biventricular global and segmental strain parameters were derived. Interstudy, intraobserver, and interobserver reproducibilities were investigated. For the assessment of the impact of the temporal resolution for the outcome in CMR‐FT, highly oversampled semi‐4 chamber and midventricular short‐axis data were acquired and reconstructed with 10 to 80 phases per cardiac cycle. A generally reduced biventricular myocardial strain was observed in Nexn‐KO Het mice. Excellent intraobserver and interobserver reproducibility was achieved in all global strains (ICC range from 0.76 to 0.99), where global right ventricle circumferential strain (RCSSAX) showed an only good interobserver reproducibility (ICC 0.65, 0.11‐0.89). For interstudy reproducibility, left ventricle longitudinal strain (LLSLAX) was the most reproducible measure of strain (ICC 0.90, 0.71‐0.97). The left ventricle radial strain (LRSSAX) (ICC 0.50, 0.10‐0.83) showed fair reproducibility and RCSSAX (ICC 0.36, 0.14‐0.74) showed only poor reproducibility. In general, compared with global strains, the segmental strains showed relatively lower reproducibility. A minimal temporal resolution of 20 phases per cardiac cycle appeared sufficient for CMR‐FT strain analysis. The analysis of myocardial strain from high‐resolution self‐gated cine images by CMR‐FT provides a highly reproducible method for assessing myocardial contraction in small rodent animals. Especially, global LV longitudinal and circumferential strain revealed excellent reproducibility of intra‐ and interobserver and interstudy measurements.
- 23 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Open AccessQuantification of Biventricular Myocardial Strain Using CMR Feature Tracking: Reproducibility in Small Animals
Myocardial strain is a well‐validated parameter for evaluating myocardial contraction. Cardiovascular magnetic resonance myocardial feature tracking (CMR‐FT) is a novel method for the quantitative measurements of myocardial strain from routine cine acquisitions. In this study, we investigated the influence of temporal resolution on tracking accuracy of CMR‐FT and the intraobserver, interobserver, and interstudy reproducibilities for biventricular strain analysis in mice from self‐gated CMR at 11.7 T. 12 constitutive nexilin knockout (Nexn‐KO) mice, heterozygous (Het, N = 6) and wild‐type (WT, N = 6), were measured with a well‐established self‐gating sequence twice within two weeks. CMR‐FT measures of biventricular global and segmental strain parameters were derived. Interstudy, intraobserver, and interobserver reproducibilities were investigated. For the assessment of the impact of the temporal resolution for the outcome in CMR‐FT, highly oversampled semi‐4 chamber and midventricular short‐axis data were acquired and reconstructed with 10 to 80 phases per cardiac cycle. A generally reduced biventricular myocardial strain was observed in Nexn‐KO Het mice. Excellent intraobserver and interobserver reproducibility was achieved in all global strains (ICC range from 0.76 to 0.99), where global right ventricle circumferential strain (RCSSAX) showed an only good interobserver reproducibility (ICC 0.65, 0.11‐0.89). For interstudy reproducibility, left ventricle longitudinal strain (LLSLAX) was the most reproducible measure of strain (ICC 0.90, 0.71‐0.97). The left ventricle radial strain (LRSSAX) (ICC 0.50, 0.10‐0.83) showed fair reproducibility and RCSSAX (ICC 0.36, 0.14‐0.74) showed only poor reproducibility. In general, compared with global strains, the segmental strains showed relatively lower reproducibility. A minimal temporal resolution of 20 phases per cardiac cycle appeared sufficient for CMR‐FT strain analysis. The analysis of myocardial strain from high‐resolution self‐gated cine images by CMR‐FT provides a highly reproducible method for assessing myocardial contraction in small rodent animals. Especially, global LV longitudinal and circumferential strain revealed excellent reproducibility of intra‐ and interobserver and interstudy measurements.
- 2 August 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (3) , 236-244
Sliding window reduced FOV reconstruction for real-time cardiac imaging
- 2 August 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (3) , 236-244
Sliding window reduced FOV reconstruction for real-time cardiac imaging
- Open Access
- 27 May 2020
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (10) , 1985-1996
Right ventricular free wall longitudinal strain and strain rate quantification with cardiovascular magnetic resonance based tissue tracking
Cardiovascular magnetic resonance based tissue tracking (CMR-TT) was reported to provide detailed insight into left ventricular mechanical features. However, inadequate knowledge of the right ventricle (RV) mechanical deformation has been acquired by this advanced technique so far. It was the aim of this study to establish reference values of RV free wall (RVFW) global, regional and segmental longitudinal peak strain and strain rate (LS and LSR), and to investigate the gender- and age-related difference as well as the base-to-apex gradient of RVFW-LS and LSR with CMR-TT. 150 healthy volunteers (75 males/females) were retrospectively and continuously recruited and subdivided into three age groups (G20–40, G41–60 and G61–80). RVFW global, regional (basal, middle-cavity and apical) and segmental LS (GLS, RLS, SLS) along with systolic and diastolic LSR were generated by post-hoc CMR-TT analysis of standard steady-state free precession long-axis four-chamber view cine images acquired at 1.5T field strength. The reference value of myocardial RVFW-GLS was − 24.9 ± 5.2%. We found that females showed more negative GLS than males except in the youngest group, and no age-related difference of GLS was observed in both gender groups. RLS and SLS presented with the same age-related tendency as GLS. The basal and middle-cavity LS were similar between each other and significantly larger than apical LS. RVFW-GLSR resulted as − 1.73 ± 0.58 s−1 and 1.69 ± 0.65 s−1 during systolic and diastolic phases, respectively. The diastolic GLSR of males tended to decline with the ageing and was significantly lower than that of females in G61–80 group. Regional and segmental LSR showed significant gender-related differences in certain basal and apical region/segments without any age-related effects. CMR-TT overcomes the difficulty in measuring RV global and segmental deformation. The establishment of the vendor-, gender- and segment-specific reference values of RVFW-LS and LSR is essential for the rapid and efficient utilization of CMR-TT modality in the clinical routine.
- 27 May 2020
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (10) , 1985-1996
Open AccessRight ventricular free wall longitudinal strain and strain rate quantification with cardiovascular magnetic resonance based tissue tracking
Cardiovascular magnetic resonance based tissue tracking (CMR-TT) was reported to provide detailed insight into left ventricular mechanical features. However, inadequate knowledge of the right ventricle (RV) mechanical deformation has been acquired by this advanced technique so far. It was the aim of this study to establish reference values of RV free wall (RVFW) global, regional and segmental longitudinal peak strain and strain rate (LS and LSR), and to investigate the gender- and age-related difference as well as the base-to-apex gradient of RVFW-LS and LSR with CMR-TT. 150 healthy volunteers (75 males/females) were retrospectively and continuously recruited and subdivided into three age groups (G20–40, G41–60 and G61–80). RVFW global, regional (basal, middle-cavity and apical) and segmental LS (GLS, RLS, SLS) along with systolic and diastolic LSR were generated by post-hoc CMR-TT analysis of standard steady-state free precession long-axis four-chamber view cine images acquired at 1.5T field strength. The reference value of myocardial RVFW-GLS was − 24.9 ± 5.2%. We found that females showed more negative GLS than males except in the youngest group, and no age-related difference of GLS was observed in both gender groups. RLS and SLS presented with the same age-related tendency as GLS. The basal and middle-cavity LS were similar between each other and significantly larger than apical LS. RVFW-GLSR resulted as − 1.73 ± 0.58 s−1 and 1.69 ± 0.65 s−1 during systolic and diastolic phases, respectively. The diastolic GLSR of males tended to decline with the ageing and was significantly lower than that of females in G61–80 group. Regional and segmental LSR showed significant gender-related differences in certain basal and apical region/segments without any age-related effects. CMR-TT overcomes the difficulty in measuring RV global and segmental deformation. The establishment of the vendor-, gender- and segment-specific reference values of RVFW-LS and LSR is essential for the rapid and efficient utilization of CMR-TT modality in the clinical routine.
- Open Access
Multi-Modal PET and MR Imaging in the Hen’s Egg Test-Chorioallantoic Membrane (HET-CAM) Model for Initial In Vivo Testing of Target-Specific Radioligands
The validation of novel target-specific radioligands requires animal experiments mostly using mice with xenografts. A pre-selection based on a simpler in vivo model would allow to reduce the number of animal experiments, in accordance with the 3Rs principles (reduction, replacement, refinement). In this respect, the chick embryo or hen’s egg test–chorioallantoic membrane (HET-CAM) model is of special interest, as it is not considered an animal until day 17. Thus, we evaluated the feasibility of quantitative analysis of target-specific radiotracer accumulation in xenografts using the HET-CAM model and combined positron emission tomography (PET) and magnetic resonance imaging (MRI). For proof-of-principle we used established prostate-specific membrane antigen (PSMA)-positive and PSMA-negative prostate cancer xenografts and the clinically widely used PSMA-specific PET-tracer [68Ga]Ga-PSMA-11. Tracer accumulation was quantified by PET and tumor volumes measured with MRI (n = 42). Moreover, gamma-counter analysis of radiotracer accumulation was done ex-vivo. A three- to five-fold higher ligand accumulation in the PSMA-positive tumors compared to the PSMA-negative tumors was demonstrated. This proof-of-principle study shows the general feasibility of the HET-CAM xenograft model for target-specific imaging with PET and MRI. The ultimate value for characterization of novel target-specific radioligands now has to be validated in comparison to mouse xenograft experiments.
Open AccessMulti-Modal PET and MR Imaging in the Hen’s Egg Test-Chorioallantoic Membrane (HET-CAM) Model for Initial In Vivo Testing of Target-Specific Radioligands
The validation of novel target-specific radioligands requires animal experiments mostly using mice with xenografts. A pre-selection based on a simpler in vivo model would allow to reduce the number of animal experiments, in accordance with the 3Rs principles (reduction, replacement, refinement). In this respect, the chick embryo or hen’s egg test–chorioallantoic membrane (HET-CAM) model is of special interest, as it is not considered an animal until day 17. Thus, we evaluated the feasibility of quantitative analysis of target-specific radiotracer accumulation in xenografts using the HET-CAM model and combined positron emission tomography (PET) and magnetic resonance imaging (MRI). For proof-of-principle we used established prostate-specific membrane antigen (PSMA)-positive and PSMA-negative prostate cancer xenografts and the clinically widely used PSMA-specific PET-tracer [68Ga]Ga-PSMA-11. Tracer accumulation was quantified by PET and tumor volumes measured with MRI (n = 42). Moreover, gamma-counter analysis of radiotracer accumulation was done ex-vivo. A three- to five-fold higher ligand accumulation in the PSMA-positive tumors compared to the PSMA-negative tumors was demonstrated. This proof-of-principle study shows the general feasibility of the HET-CAM xenograft model for target-specific imaging with PET and MRI. The ultimate value for characterization of novel target-specific radioligands now has to be validated in comparison to mouse xenograft experiments.
- Open Access
- 29 March 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (7) , e4300
Feasibility of real‐time cardiac MRI in mice using tiny golden angle radial sparse
Cardiovascular magnetic resonance imaging has proven valuable for the assessment of structural and functional cardiac abnormalities. Even although it is an established imaging method in small animals, the long acquisition times of gated or self‐gated techniques still limit its widespread application. In this study, the application of tiny golden angle radial sparse MRI (tyGRASP) for real‐time cardiac imaging was tested in 12 constitutive nexilin (Nexn) knock‐out (KO) mice, both heterozygous (Het, N = 6) and wild‐type (WT, N = 6), and the resulting functional parameters were compared with a well‐established self‐gating approach. Real‐time images were reconstructed for different temporal resolutions of between 16.8 and 79.8 ms per image. The suggested approach was additionally tested for dobutamine stress and qualitative first‐pass perfusion imaging. Measurements were repeated twice within 2 weeks for reproducibility assessment. In direct comparison with the high‐quality, self‐gated technique, the real‐time approach did not show any significant differences in global function parameters for acquisition times below 50 ms (rest) and 31.5 ms (stress). Compared with WT, the end‐diastolic volume (EDV) and end‐systolic volume (ESV) were markedly higher (P < 0.05) and the ejection fraction (EF) was significantly lower in the Het Nexn‐KO mice at rest (P < 0.001). For the stress investigation, a clear decrease of EDV and ESV, and an increase in EF, but maintained stroke volume, could be observed in both groups. Combined with ECG‐triggering, tyGRASP provided first‐pass perfusion data with a temporal resolution of one image per heartbeat, allowing the quantitative assessment of upslope curves in the blood‐pool and myocardium. Excellent inter‐study reproducibility was achieved in all the functional parameters. The tyGRASP is a valuable real‐time MRI technique for mice, which significantly reduces the scan time in preclinical cardiac functional imaging, providing sufficient image quality for deriving accurate functional parameters, and has the potential to investigate real‐time and beat‐to‐beat changes.
- 29 March 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (7) , e4300
Open AccessFeasibility of real‐time cardiac MRI in mice using tiny golden angle radial sparse
Cardiovascular magnetic resonance imaging has proven valuable for the assessment of structural and functional cardiac abnormalities. Even although it is an established imaging method in small animals, the long acquisition times of gated or self‐gated techniques still limit its widespread application. In this study, the application of tiny golden angle radial sparse MRI (tyGRASP) for real‐time cardiac imaging was tested in 12 constitutive nexilin (Nexn) knock‐out (KO) mice, both heterozygous (Het, N = 6) and wild‐type (WT, N = 6), and the resulting functional parameters were compared with a well‐established self‐gating approach. Real‐time images were reconstructed for different temporal resolutions of between 16.8 and 79.8 ms per image. The suggested approach was additionally tested for dobutamine stress and qualitative first‐pass perfusion imaging. Measurements were repeated twice within 2 weeks for reproducibility assessment. In direct comparison with the high‐quality, self‐gated technique, the real‐time approach did not show any significant differences in global function parameters for acquisition times below 50 ms (rest) and 31.5 ms (stress). Compared with WT, the end‐diastolic volume (EDV) and end‐systolic volume (ESV) were markedly higher (P < 0.05) and the ejection fraction (EF) was significantly lower in the Het Nexn‐KO mice at rest (P < 0.001). For the stress investigation, a clear decrease of EDV and ESV, and an increase in EF, but maintained stroke volume, could be observed in both groups. Combined with ECG‐triggering, tyGRASP provided first‐pass perfusion data with a temporal resolution of one image per heartbeat, allowing the quantitative assessment of upslope curves in the blood‐pool and myocardium. Excellent inter‐study reproducibility was achieved in all the functional parameters. The tyGRASP is a valuable real‐time MRI technique for mice, which significantly reduces the scan time in preclinical cardiac functional imaging, providing sufficient image quality for deriving accurate functional parameters, and has the potential to investigate real‐time and beat‐to‐beat changes.
- 1 March 2019
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 40 (2) , 393-400
Effects of Various Trajectories on Tissue Preservation in Cochlear Implant Surgery: A Micro-Computed Tomography and Synchrotron Radiation Phase-Contrast Imaging Study
Objectives: The purpose of this study was to evaluate the three-dimensional (3D) anatomy and potential damage to the hook region of the human cochlea following various trajectories at cochlear implantation (CI). The goal was to determine which of the approaches can avoid lesions to the soft tissues, including the basilar membrane and its suspension to the lateral wall. Currently, there is increased emphasis on conservation of inner ear structures, even in nonhearing preservation CI surgery. Design: Micro-computed tomography and various CI approaches were made in an archival collection of macerated and freshly fixed human temporal bones. Furthermore, synchrotron radiation phase-contrast imaging was used to reproduce the soft tissues. The 3D anatomy was investigated using bony and soft tissue algorithms, and influences on inner ear structures were examined. Results: Micro-computed tomography with 3D rendering demonstrated the topography of the round window (RW) and osseous spiral laminae, while synchrotron imaging allowed reproduction of soft tissues such as the basilar membrane and its suspension around the RW membrane. Anterior cochleostomies and anteroinferior cochleostomies invariably damaged the intracochlear soft tissues while inferior cochleostomies sporadically left inner ear structures unaffected. Conclusions: Results suggest that cochleostomy approaches often traumatize the soft tissues at the hook region at CI surgery. For optimal structural preservation, the RW approach is, therefore, recommended.
- 1 March 2019
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 40 (2) , 393-400
Effects of Various Trajectories on Tissue Preservation in Cochlear Implant Surgery: A Micro-Computed Tomography and Synchrotron Radiation Phase-Contrast Imaging Study
Objectives: The purpose of this study was to evaluate the three-dimensional (3D) anatomy and potential damage to the hook region of the human cochlea following various trajectories at cochlear implantation (CI). The goal was to determine which of the approaches can avoid lesions to the soft tissues, including the basilar membrane and its suspension to the lateral wall. Currently, there is increased emphasis on conservation of inner ear structures, even in nonhearing preservation CI surgery. Design: Micro-computed tomography and various CI approaches were made in an archival collection of macerated and freshly fixed human temporal bones. Furthermore, synchrotron radiation phase-contrast imaging was used to reproduce the soft tissues. The 3D anatomy was investigated using bony and soft tissue algorithms, and influences on inner ear structures were examined. Results: Micro-computed tomography with 3D rendering demonstrated the topography of the round window (RW) and osseous spiral laminae, while synchrotron imaging allowed reproduction of soft tissues such as the basilar membrane and its suspension around the RW membrane. Anterior cochleostomies and anteroinferior cochleostomies invariably damaged the intracochlear soft tissues while inferior cochleostomies sporadically left inner ear structures unaffected. Conclusions: Results suggest that cochleostomy approaches often traumatize the soft tissues at the hook region at CI surgery. For optimal structural preservation, the RW approach is, therefore, recommended.