Fluorescent sensing layer for the determination of L-malic acid in wine
- 4 January 2007
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 387 (6) , 2297-2305
Abstract
An enzymatic method for determining L-malic acid in wine based on an L-malate sensing layer with nicotinamide adenine dinucleotide (NAD+), L-malate dehydrogenase (L-MDH) and diaphorase (DI), immobilized by sol-gel technology, was constructed and evaluated. The sol-gel glass was prepared with tetramethoxysilane (TMOS), water and HCl. L-MDH catalyzes the reaction between L-malate and NAD+, producing NADH, whose fluorescence (λ exc = 340 nm, λ em = 430 nm) could be directly related to the amount of L-malate. NADH is converted to NAD+ by applying hexacyanoferrate(III) as oxidant in the presence of DI. Some parameters affecting sol-gel encapsulation and the pH of the enzymatic reaction were studied. The sensing layer has a dynamic range of 0.1–1.0 g/L of L-malate and a long-term storage stability of 25 days. It exhibits acceptable reproducibility [s r(%)≈10] and allows six regenerations. The content of L-malic acid was determined for different types of wine, and polyvinylpolypyrrolidone (PVPP) was used as a bleaching agent with red wine. The results obtained for the wine samples using the sensing layer are comparable to those obtained from a reference method based on UV-vis molecular absorption spectrometry, if the matrix effect is corrected for.Keywords
This publication has 26 references indexed in Scilit:
- Optimization of the determination of organic acids and sugars in fruit juices by ion-exclusion liquid chromatographyJournal of Food Composition and Analysis, 2005
- Sequential fluorometric quantification of malic acid enantiomers by a single line flow-injection system using immobilized-enzyme reactorsTalanta, 2005
- Screen-printed enzyme electrodes for the detection of marker analytes during winemakingAnalytica Chimica Acta, 2004
- Kinetic determination of l(−)malic acid in wines using sequential injection analysisAnalytica Chimica Acta, 2003
- Electrochemical evaluation of resistance to localised corrosion of vitreous coatings containing particles applied on metallic substrates for biomedical applicationsMaterials Letters, 2003
- Ultrasound-assisted extraction and determination of tartaric and malic acids from grapes and winemaking by-productsAnalytica Chimica Acta, 2002
- Sequential injection Fourier transform infrared spectroscopy for the simultaneous determination of organic acids and sugars in soft drinks employing automated solid phase extractionAnalytica Chimica Acta, 2000
- Sol−Gel-Encapsulated Alcohol Dehydrogenase as a Versatile, Environmentally Stabilized Sensor for Alcohols and AldehydesJournal of the American Chemical Society, 1998
- Detection of Exogenous Sugars or Organic Acids Addition in Pineapple Juices and Concentrates by 13C IRMS AnalysisJournal of Agricultural and Food Chemistry, 1997
- Calcium biosensing with a sol–gel immobilized photoproteinThe Analyst, 1996