Félix Gallarta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Félix Gallarta has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Juan Ramon Castillo
Analytical Spectroscopy and Sensors Group (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, 50009-Zaragoza, Spain
3 shared publications - Celia Sabando-Fraile
Department of Mechanical Engineering, University of La Rioja, Logroño, Spain
2 shared publications Javier Galbán
Analytical Chemistry Department, University College of La Rioja (University of Zaragoza), Logroño-26001 Spain
2 shared publicationsJesús Sanz
Analytical Chemistry Department, University College of La Rioja (University of Zaragoza), Logroño-26001 Spain
2 shared publications- Marina Corral-Bobadilla
Department of Mechanical Engineering, University of La Rioja, Logroño, Spain
2 shared publications - Ana González-Marcos
Department of Mechanical Engineering, Universidad de La Rioja, Logroño, Spain
1 shared publication
Latest Publications
- Open Access
- 21 April 2026
- Published by Springer Nature in International Journal of Environmental Research
- Vol. 20 (3) , 138
Lignocellulosic Biosorbents from Vitis vinifera Agro-Waste for Cd(II) Removal: Isotherm and Kinetic Modelling in an LCA Framework
- 21 April 2026
- Published by Springer Nature in International Journal of Environmental Research
- Vol. 20 (3) , 138
Open AccessLignocellulosic Biosorbents from Vitis vinifera Agro-Waste for Cd(II) Removal: Isotherm and Kinetic Modelling in an LCA Framework
- Open Access
- 24 March 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 926, 171947
Applying circular economy principles and life cycle assessment: A novel approach using vine shoots waste for cadmium removal from water
- 24 March 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 926, 171947
Open AccessApplying circular economy principles and life cycle assessment: A novel approach using vine shoots waste for cadmium removal from water
- Open Access
- 17 November 2023
- Published by Elsevier in Current Research in Food Science
- Vol. 7, 100639
Wine corks decontamination using plasma activated water
- 17 November 2023
- Published by Elsevier in Current Research in Food Science
- Vol. 7, 100639
Open AccessWine corks decontamination using plasma activated water
- 4 January 2007
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 387 (6) , 2297-2305
Fluorescent sensing layer for the determination of L-malic acid in wine
An enzymatic method for determining L-malic acid in wine based on an L-malate sensing layer with nicotinamide adenine dinucleotide (NAD+), L-malate dehydrogenase (L-MDH) and diaphorase (DI), immobilized by sol-gel technology, was constructed and evaluated. The sol-gel glass was prepared with tetramethoxysilane (TMOS), water and HCl. L-MDH catalyzes the reaction between L-malate and NAD+, producing NADH, whose fluorescence (λ exc = 340 nm, λ em = 430 nm) could be directly related to the amount of L-malate. NADH is converted to NAD+ by applying hexacyanoferrate(III) as oxidant in the presence of DI. Some parameters affecting sol-gel encapsulation and the pH of the enzymatic reaction were studied. The sensing layer has a dynamic range of 0.1–1.0 g/L of L-malate and a long-term storage stability of 25 days. It exhibits acceptable reproducibility [s r(%)≈10] and allows six regenerations. The content of L-malic acid was determined for different types of wine, and polyvinylpolypyrrolidone (PVPP) was used as a bleaching agent with red wine. The results obtained for the wine samples using the sensing layer are comparable to those obtained from a reference method based on UV-vis molecular absorption spectrometry, if the matrix effect is corrected for.
- 4 January 2007
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 387 (6) , 2297-2305
Fluorescent sensing layer for the determination of L-malic acid in wine
An enzymatic method for determining L-malic acid in wine based on an L-malate sensing layer with nicotinamide adenine dinucleotide (NAD+), L-malate dehydrogenase (L-MDH) and diaphorase (DI), immobilized by sol-gel technology, was constructed and evaluated. The sol-gel glass was prepared with tetramethoxysilane (TMOS), water and HCl. L-MDH catalyzes the reaction between L-malate and NAD+, producing NADH, whose fluorescence (λ exc = 340 nm, λ em = 430 nm) could be directly related to the amount of L-malate. NADH is converted to NAD+ by applying hexacyanoferrate(III) as oxidant in the presence of DI. Some parameters affecting sol-gel encapsulation and the pH of the enzymatic reaction were studied. The sensing layer has a dynamic range of 0.1–1.0 g/L of L-malate and a long-term storage stability of 25 days. It exhibits acceptable reproducibility [s r(%)≈10] and allows six regenerations. The content of L-malic acid was determined for different types of wine, and polyvinylpolypyrrolidone (PVPP) was used as a bleaching agent with red wine. The results obtained for the wine samples using the sensing layer are comparable to those obtained from a reference method based on UV-vis molecular absorption spectrometry, if the matrix effect is corrected for.
- 1 January 1995
- Published by Taylor & Francis in Analytical Letters
- Vol. 28 (1) , 121-146
Determination of Tellurium by Gas Phase Molecular Absorption Spectrometry After Hydrogen Telluride Generation
A method for determination of tellurium(IV) or tellurium(VI) is described that involves hydrogen telluride generation by reduction with sodium tetrahydro-borate(III), evolution of hydride with HCl solution, transport into a flow-cell placed in a UV-visible molecular absorption spectrophotometer and measurement of gas at 190 nm. Hydride generation and determination procedures are optimized, based on height and area of absorbance versus time profile of hydrogen telluride generated. Using the best experimental conditions found the calibration curve is linear from 5 to 100 μg/ml of tellurium, 1.1 μg/ml of tellurium(IV) or 3.1 μg/ml of tellurium(VI) can be detected, and relative standard deviation ranges from 4 to 7%. The method is applied to the analysis of additives for synthetic rubber making.
- 1 January 1995
- Published by Taylor & Francis in Analytical Letters
- Vol. 28 (1) , 121-146
Determination of Tellurium by Gas Phase Molecular Absorption Spectrometry After Hydrogen Telluride Generation
A method for determination of tellurium(IV) or tellurium(VI) is described that involves hydrogen telluride generation by reduction with sodium tetrahydro-borate(III), evolution of hydride with HCl solution, transport into a flow-cell placed in a UV-visible molecular absorption spectrophotometer and measurement of gas at 190 nm. Hydride generation and determination procedures are optimized, based on height and area of absorbance versus time profile of hydrogen telluride generated. Using the best experimental conditions found the calibration curve is linear from 5 to 100 μg/ml of tellurium, 1.1 μg/ml of tellurium(IV) or 3.1 μg/ml of tellurium(VI) can be detected, and relative standard deviation ranges from 4 to 7%. The method is applied to the analysis of additives for synthetic rubber making.
- 1 December 1991
- Published by Elsevier in Analytica Chimica Acta
- Vol. 255 (1) , 113-120
Simultaneous determination of inorganic arsenic(III) and arsenic(V) by arsine generation and gas-phase molecular absorption spectrometry
- 1 December 1991
- Published by Elsevier in Analytica Chimica Acta
- Vol. 255 (1) , 113-120
Simultaneous determination of inorganic arsenic(III) and arsenic(V) by arsine generation and gas-phase molecular absorption spectrometry
- 1 January 1988
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 113 (9) , 1387-1391
Determination of selenium by hydride generation ultraviolet-visible molecular absorption spectrometry with diode-array detection
A method for the determination of selenium is described that involves hydrogen selenide generation by reduction with sodium tetrahydroborate(III) and subsequent transfer, using nitrogen as carrier gas, into a flow cell placed in a UV-visible molecular absorption spectrometer with diode-array detection. Quantitative determination is performed at 220 nm, taking 8 s for total hydride generation and measurement. The time required for two determinations is 30 s. The limit of detection obtained was 1.8 µg of SeIV in a sample volume of 2 ml and the calibration graph is linear from 10 to 150 µg of selenium in a sample of the same volume. The method has been applied to the determination of selenium in a health-care product.
- 1 January 1988
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 113 (9) , 1387-1391
Determination of selenium by hydride generation ultraviolet-visible molecular absorption spectrometry with diode-array detection
A method for the determination of selenium is described that involves hydrogen selenide generation by reduction with sodium tetrahydroborate(III) and subsequent transfer, using nitrogen as carrier gas, into a flow cell placed in a UV-visible molecular absorption spectrometer with diode-array detection. Quantitative determination is performed at 220 nm, taking 8 s for total hydride generation and measurement. The time required for two determinations is 30 s. The limit of detection obtained was 1.8 µg of SeIV in a sample volume of 2 ml and the calibration graph is linear from 10 to 150 µg of selenium in a sample of the same volume. The method has been applied to the determination of selenium in a health-care product.
- 1 January 1988
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 330 (6) , 510-515
Antimony determination by hydride generation — UV-visible molecular absorption spectrophotometry with diode-array detection
- 1 January 1988
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 330 (6) , 510-515
Antimony determination by hydride generation — UV-visible molecular absorption spectrophotometry with diode-array detection
- 1 January 1987
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 2 (1) , 77-79
Determination of metals in poly(vinyl chloride) by atomic absorption spectrometry. Part 2. Determination of lead and magnesium in samples of poly(vinyl chloride) with a high content of alkaline earths
This is a continuation of the study of the use of EDTA in ammonia solution to dissolve the precipitate formed when a sample of PVC with a high content of alkaline earths is attacked with sulphuric acid and hydrogen peroxide. The method is used to determine lead and magnesium, and is both rapid and reliable.
- 1 January 1987
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 2 (1) , 77-79
Determination of metals in poly(vinyl chloride) by atomic absorption spectrometry. Part 2. Determination of lead and magnesium in samples of poly(vinyl chloride) with a high content of alkaline earths
This is a continuation of the study of the use of EDTA in ammonia solution to dissolve the precipitate formed when a sample of PVC with a high content of alkaline earths is attacked with sulphuric acid and hydrogen peroxide. The method is used to determine lead and magnesium, and is both rapid and reliable.