On‐line preconcentration of weak electrolytes by electrokinetic accumulation in CE: Experiment and simulation
- 10 May 2007
- journal article
- ce and-cec
- Published by Wiley in Electrophoresis
- Vol. 28 (10) , 1540-1547
Abstract
A new on-line preconcentration technique was developed that makes possible to determine nanomolar concentrations of weak acidic analytes in CE. The method consists of long-running electrokinetic sample injection and stacking (electrokinetic immobilization) of the analytes at a boundary of two electrolytes with different pH values (pH 9.5 and 2.5) and consequent mobilization of the stacked uncharged analytes in a micellar system (containing SDS micelles). Several factors including buffer concentration, pH, applied voltage, time of preconcentration, and SDS concentration were tested to optimize the analysis method. An about 4600-fold increase of the sample concentration (in comparison with the standard CZE) can be achieved during the preconcentration step. Two preservatives applied in food industry – benzoic acid and sorbic acid were used as model samples. The applicability of the proposed method in food analysis was demonstrated by determination of nanomolar concentrations of benzoic acid in sunflower oil. An extended version of the computer program Simul was used for modeling both the preconcentration and mobilization processes taking place in the capillary.Keywords
This publication has 38 references indexed in Scilit:
- Full-capillary sample stacking/sweeping-MEKC for the separation of naphthalene-2,3-dicarboxaldehyde-derivatized tryptophan and isoleucineElectrophoresis, 2005
- pH-mediated acid stacking with reverse pressure for the analysis of cationic pharmaceuticals in capillary electrophoresisElectrophoresis, 2005
- Sensitivity improvement on detection of Coptidis alkaloids by sweeping in capillary electrophoresisJournal of Pharmaceutical and Biomedical Analysis, 2005
- Sweeping via Dynamic Complexation with Cyclohexane-1,2-diaminetetraacetic Acid for Trace Metal Analysis in Capillary ElectrophoresisChromatographia, 2004
- Eigenmobilities in background electrolytes for capillary zone electrophoresis: III. Linear theory of electromigrationElectrophoresis, 2004
- Positively Charged Sol−Gel Coatings for On-Line Preconcentration of Amino Acids in Capillary ElectrophoresisAnalytical Chemistry, 2003
- Thousandfold signal increase using field‐amplified sample stacking for on‐chip electrophoresisElectrophoresis, 2003
- Investigation of the mechanism of pH‐mediated stacking of anions for the analysis of physiological samples by capillary electrophoresisElectrophoresis, 2003
- High‐sensitivity analyses of metabolites in biological samples by capillary electrophoresis using dynamic pH junction‐sweepingThe Chemical Record, 2002
- Computer simulation and experimental evaluation of on-column sample preconcentration in capillary zone electrophoresis by discontinuous buffer systemsAnalytical Chemistry, 1993