Juraj Ševčík
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Juraj Ševčík has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Eva Tesařová
Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Prague, Czech Republic
2 shared publications - Adriána Miškovčíková
Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University in Bratislava, Mlynská dolina CH2, Ilkovičova 6, 84215 Bratislava, Slovakia
1 shared publication - Bohuslav Gaš
Berlin) Christian Klampfl (Linz)
1 shared publication Daniel W. Armstrong
Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, USA
1 shared publication- Eva Vargová
Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University in Bratislava, Mlynská dolina CH2, Ilkovičova 6, 84215 Bratislava, Slovakia
1 shared publication Jan Grafnetter
Department of Analytical Chemistry, Faculty of Science, Charles University, Albertov 2030, 12840 Prague, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 13 December 2020
- Published by MDPI AG in Separations
- Vol. 7 (4) , 72
Determination of Carminic Acid in Foodstuffs and Pharmaceuticals by Microchip Electrophoresis with Photometric Detection
This paper presents a novel miniaturized analytical method for the determination of carminic acid, a natural red food dye, in complex food and pharmaceutical matrices by microchip electrophoresis (MCE) with photometric detection. MCE has become a very attractive microscale separation technique because it offers high-speed, high-throughput, small sample injection volume and low reagents consumption. Fast determination of carminic acid in less than 5 min was achieved on a poly(methyl methacrylate) microchip in anionic separation mode at pH 6. Photometric detector based on light-emitting diode technology was set to a wavelength of 490 nm. Using a sample injection volume of 900 nL, a limit of detection of 69 nmol L−1 was achieved. A wide linear dynamic range over four orders of magnitude (from nmol L−1 to mmol L−1) was observed for peak area. Developed method provided favorable intra- and inter-day repeatability of the migration time (up to 2.5% RSD), as well as the repeatability of the peak area (less than 1.9% RSD), regardless of the sample type. The content of carminic acid was determined in various foodstuffs and pharmaceuticals, such as candies, saffron, non-alcoholic drink, and sore throat lozenges with good recoveries (92.5–104.0%).
- 13 December 2020
- Published by MDPI AG in Separations
- Vol. 7 (4) , 72
Open AccessDetermination of Carminic Acid in Foodstuffs and Pharmaceuticals by Microchip Electrophoresis with Photometric Detection
This paper presents a novel miniaturized analytical method for the determination of carminic acid, a natural red food dye, in complex food and pharmaceutical matrices by microchip electrophoresis (MCE) with photometric detection. MCE has become a very attractive microscale separation technique because it offers high-speed, high-throughput, small sample injection volume and low reagents consumption. Fast determination of carminic acid in less than 5 min was achieved on a poly(methyl methacrylate) microchip in anionic separation mode at pH 6. Photometric detector based on light-emitting diode technology was set to a wavelength of 490 nm. Using a sample injection volume of 900 nL, a limit of detection of 69 nmol L−1 was achieved. A wide linear dynamic range over four orders of magnitude (from nmol L−1 to mmol L−1) was observed for peak area. Developed method provided favorable intra- and inter-day repeatability of the migration time (up to 2.5% RSD), as well as the repeatability of the peak area (less than 1.9% RSD), regardless of the sample type. The content of carminic acid was determined in various foodstuffs and pharmaceuticals, such as candies, saffron, non-alcoholic drink, and sore throat lozenges with good recoveries (92.5–104.0%).
- 10 May 2007
- Published by Wiley in Electrophoresis
- Vol. 28 (10) , 1540-1547
On‐line preconcentration of weak electrolytes by electrokinetic accumulation in CE: Experiment and simulation
A new on-line preconcentration technique was developed that makes possible to determine nanomolar concentrations of weak acidic analytes in CE. The method consists of long-running electrokinetic sample injection and stacking (electrokinetic immobilization) of the analytes at a boundary of two electrolytes with different pH values (pH 9.5 and 2.5) and consequent mobilization of the stacked uncharged analytes in a micellar system (containing SDS micelles). Several factors including buffer concentration, pH, applied voltage, time of preconcentration, and SDS concentration were tested to optimize the analysis method. An about 4600-fold increase of the sample concentration (in comparison with the standard CZE) can be achieved during the preconcentration step. Two preservatives applied in food industry – benzoic acid and sorbic acid were used as model samples. The applicability of the proposed method in food analysis was demonstrated by determination of nanomolar concentrations of benzoic acid in sunflower oil. An extended version of the computer program Simul was used for modeling both the preconcentration and mobilization processes taking place in the capillary.
- 10 May 2007
- Published by Wiley in Electrophoresis
- Vol. 28 (10) , 1540-1547
On‐line preconcentration of weak electrolytes by electrokinetic accumulation in CE: Experiment and simulation
A new on-line preconcentration technique was developed that makes possible to determine nanomolar concentrations of weak acidic analytes in CE. The method consists of long-running electrokinetic sample injection and stacking (electrokinetic immobilization) of the analytes at a boundary of two electrolytes with different pH values (pH 9.5 and 2.5) and consequent mobilization of the stacked uncharged analytes in a micellar system (containing SDS micelles). Several factors including buffer concentration, pH, applied voltage, time of preconcentration, and SDS concentration were tested to optimize the analysis method. An about 4600-fold increase of the sample concentration (in comparison with the standard CZE) can be achieved during the preconcentration step. Two preservatives applied in food industry – benzoic acid and sorbic acid were used as model samples. The applicability of the proposed method in food analysis was demonstrated by determination of nanomolar concentrations of benzoic acid in sunflower oil. An extended version of the computer program Simul was used for modeling both the preconcentration and mobilization processes taking place in the capillary.
- 17 September 2004
- Published by Elsevier in Journal of Chromatography A
- Vol. 1049 (1-2) , 43-49
Optimization of binary porogen solvent composition for preparation of butyl methacrylate monoliths in capillary liquid chromatography
- 17 September 2004
- Published by Elsevier in Journal of Chromatography A
- Vol. 1049 (1-2) , 43-49
Optimization of binary porogen solvent composition for preparation of butyl methacrylate monoliths in capillary liquid chromatography