Diffusion gradient nonlinearity bias correction reduces bias of breast cancer bone metastasis ADC values
- 16 July 2019
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 51 (3) , 904-911
Abstract
Contract grant sponsor: Health Research Fund of Central Denmark Region.Background: Diffusion gradient nonlinearity (DGNL) bias causes apparent diffusion coefficient (ADC) values to drop with increasing superior–inferior (SI) isocenter offset. This is a concern when performing quantitative diffusion‐weighted imaging (DWI).Purpose/Hypothesis: To investigate if DGNL ADC bias can be corrected in breast cancer bone metastases using a clinical DWI protocol and an online correction algorithm.Study Type: Prospective.Subjects/Phantom: A diffusion phantom (Model 128, High Precision Devices, Boulder, CO) was used for in vitro validation. Twenty‐three women with bone‐metastasizing breast cancer were enrolled to assess DGNL correction in vivo.Field Strength/Sequence: DWI was performed on a 1.5T MRI system as single‐shot, spin‐echo, echo‐planar imaging with short‐tau inversion recovery (STIR) fat‐saturation. ADC maps with and without DGNL correction were created from the b50 and b800 images.Assessment: Uncorrected and DGNL‐corrected ADC values were measured in phantom and bone metastases by placing regions of interest on b800 images and copying them to the ADC map. The SI offset was recorded.Statistical Tests: In all, 79 bone metastases were assessed. ADC values with and without DGNL correction were compared at 14 cm SI offset using a two‐tailed t‐test.Results: In the diffusion phantom, DGNL correction increased SI offset, where ADC bias was lower than 5%, from 7.3–13.8 cm. Of the 23 patients examined, six had no metastases in the covered regions. In the remaining patients, bias of uncorrected bone metastasis ADC values was 19.1% (95% confidence interval [CI]: 15.4–22.9%) at 14 cm SI offset. After DGNL correction, ADC bias was significantly reduced to 3.5% (95% CI: 0.7–6.3%, P < 0.001), thus reducing bias due to DGNL by 82%.Data Conclusion: Online DGNL correction corrects DGNL ADC value bias and allows increased station lengths in the SI direction.Level of Evidence: 2Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2020;51:904–911.Keywords
This publication has 26 references indexed in Scilit:
- Assessing the Relation Between Bone Marrow Signal Intensity and Apparent Diffusion Coefficient in Diffusion-Weighted MRIAmerican Journal of Roentgenology, 2013
- Improved correction for gradient nonlinearity effects in diffusion‐weighted imagingJournal of Magnetic Resonance Imaging, 2012
- Multi‐system repeatability and reproducibility of apparent diffusion coefficient measurement using an ice‐water phantomJournal of Magnetic Resonance Imaging, 2012
- Diffusion coefficient measurement using a temperature‐controlled fluid for quality control in multicenter studiesJournal of Magnetic Resonance Imaging, 2011
- Assessing response in bone metastases in prostate cancer with diffusion weighted MRIEuropean Radiology, 2011
- Bone Metastases from Prostate Cancer: Assessing Treatment Response by Using Diffusion-weighted Imaging and Functional Diffusion Maps—Initial ObservationsRadiology, 2010
- Reproducibility and changes in the apparent diffusion coefficients of solid tumours treated with combretastatin A4 phosphate and bevacizumab in a two-centre phase I clinical trialEuropean Radiology, 2009
- New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)European Journal of Cancer, 2009
- Bone Imaging in Metastatic Breast CancerJournal of Clinical Oncology, 2004
- Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion‐weighted imagingMagnetic Resonance in Medicine, 2003