Determination of carbon in microplastics and single cells by total consumption microdroplet ICP-TOFMS
Authors:
Open Access
- 8 December 2023
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (11) , 2773-2781
Abstract
Recently, spICP-MS analyses of microplastics have demonstrated that the detection capabilities of ICP-MS are sufficient to determine the size and composition of such materials. However, solution nebulization or microdroplet generation limits the sizes of droplets, microparticles, or cells that can be efficiently introduced into commonly used horizontal ICP-MS configurations. Therefore, we introduced the development of a downward-pointing ICP coupled to a time-of-flight mass spectrometer (ICP-TOFMS), which enables quantitative transport of large microdroplets (diameters up to 90 µm) into the ICP. Here, we report the capabilities of downward ICP-TOFMS for the quantitative analysis of single cells and microplastic particles. For calibration of element mass amount per particle or cell, microdroplets (70 µm diameter) composed of multielement solutions were measured by ICP-TOFMS. Microplastic beads (polystyrene) and spleenocyte cells were then also embedded in microdroplets and measured by ICP-TOFMS with ion optics optimized to determine the signals from 12C+ and other isotopes of interest, including 140Ce, 153Eu, 165Ho, and 175Lu from the REE beads and 31P for the cells. The results achieved using the prototype instrument of a vertical downward-pointing ICP-TOFMS demonstrate that such a plasma configuration is well suited to analyze microplastics and single cells. For single microbead and cell analyses, the critical mass for carbon was 4.8 pg, and the mean determined carbon mass amounts were 14 and 23 pg, respectively. For the microbead analysis, the detected carbon mass corresponds to a particle diameter of 2.93 ± 0.24 µm, which is consistent with the scanning (transmission) electron microscopy–determined diameter of 2.97 ± 0.04 µm. Furthermore, in the analysis of spleenocyte cells, carbon and phosphorus masses were determined to be correlated. Graphical abstractKeywords
Funding Information
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (162879, 197224)
- Swiss National Science
- Swiss Federal Institute of Technology Zurich
This publication has 39 references indexed in Scilit:
- An introduction to mass cytometry: fundamentals and applicationsCancer Immunology, Immunotherapy, 2013
- A prototype of a new inductively coupled plasma time-of-flight mass spectrometer providing temporally resolved, multi-element detection of short signals generated by single particles and dropletsJournal of Analytical Atomic Spectrometry, 2012
- Fundamental studies on the ablation behaviour of carbon in LA-ICP-MS with respect to the suitability as internal standardJournal of Analytical Atomic Spectrometry, 2012
- Time-resolved ICP-MS measurement for single-cell analysis and on-line cytometryJournal of Analytical Atomic Spectrometry, 2010
- Metal-containing polystyrene beads as standards for mass cytometryJournal of Analytical Atomic Spectrometry, 2010
- Characterization of particles made by desolvation of monodisperse microdroplets of analyte solutions and particle suspensions for nanoparticle calibration in inductively coupled plasma spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2010
- Behavior of Bacteria in the Inductively Coupled Plasma: Atomization and Production of Atomic Ions for Mass SpectrometryAnalytical Chemistry, 2005
- Determination of carbon isotope ratios in amino acids, proteins, and oligosaccharides by inductively coupled plasma-mass spectrometryJournal of the American Society for Mass Spectrometry, 2003
- Overview of Cell Fixatives and Cell Membrane Permeants1999
- Development of an ICP−IDMS Method for Dissolved Organic Carbon Determinations and Its Application to Chromatographic Fractions of Heavy Metal Complexes with Humic SubstancesAnalytical Chemistry, 1998