Histology of AlphaCor Skirts
Authors:
- C R HicksCHC R Hicks
- L WernerLWL Werner
- S VijayasekaranSVS Vijayasekaran
- N MamalisNMN Mamalis
- D J AppleDAD J Apple
- 1 November 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Cornea
- Vol. 24 (8) , 933-940
Abstract
To report histologic findings in 14 AlphaCor artificial corneas implanted during clinical trials and subsequently explanted from human subjects following complications, so as to evaluate biointegration within the device skirt. Explants were fixed and sectioned in paraffin. Histologic findings related to the device skirt were compared with earlier histologic results from animal studies and correlated with clinical histories. Two devices had been removed due to complications related to the optic alone, 11 following stromal melting overlying the biointegratable sponge skirt and 1 due to a retroprosthetic membrane. All devices demonstrated normal skirt porosity. Biointegration was similar to that found in animal studies but qualitatively appeared reduced in the affected areas in patients with overlying stromal melting prior to explantation. Patients with a longer history of melting prior to explantation demonstrated presence of inflammatory cells around the device. Histologic findings of the AlphaCor skirt in humans are consistent with earlier animal studies. This study confirms that biointegration by host fibroblastic cells, with collagen deposition occurs after AlphaCor implantation in humans. In cases in which stromal melting had occurred, biointegration is seen to be reduced. On correlating preoperative clinical factors with biointegration observed histologically, preoperative vascularization appears not to be required for AlphaCor biointegration.Keywords
This publication has 22 references indexed in Scilit:
- Cataract surgery with the AlphaCor artificial corneaJournal of Cataract & Refractive Surgery, 2004
- Deposits in artificial corneas: risk factors and preventionClinical & Experimental Ophthalmology, 2004
- AlphaCor??? CasesCornea, 2003
- Indications and Technique: AlphaCor™ Artificial CorneaTechniques in Ophthalmology, 2003
- Device Exchange with AlphaCor™Techniques in Ophthalmology, 2003
- Corneal replacement using a synthetic hydrogel cornea, AlphaCor™: device, preliminary outcomes and complicationsEye, 2003
- Outcomes of Implantation of an Artificial Cornea, AlphaCorCornea, 2002
- Production of neocollagen by cells invading hydrogel sponges implanted in the rabbit corneaGraefe's Archive for Clinical and Experimental Ophthalmology, 1996
- Interpenetrating polymer network (IPN) as a permanent joint between the elements of a new type of artificial corneaJournal of Biomedical Materials Research, 1994
- Tissue Interaction with Hydrogel Sponges Implanted in the Rabbit CorneaCornea, 1993