CHCelia R. Hicks

Celia R. Hicks

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Celia R. Hicks has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Orbital implants: potential new directions

    by Celia R Hicks, David Morrison, Xia Lou, Geoffrey J Crawford, Adam Gadjatsy, Ian J Constable

    This article reviews orbital implants used to replace an eye after enucleation or evisceration. Advantages of implant placement are described, with discussion of implant and wrap material, and design features that affect clinical outcomes. Implants may be porous or nonporous, pegged for linkage with a cosmetic shell or unpegged, and may be wrapped with a covering material or tissue or unwrapped. Device shape, volume and material qualities affect tissue tolerance and the risk of exposure or extrusion. Limitations of currently available devices are discussed, with factors affecting surgeon and patient choice. Ideally, a device should be easy to insert, avoid the need for wrapping or adjunctive tissues, be light, biointegratable, comfortable after implantation and provide satisfactory orbital volume replacement, movement and cosmesis without requiring further surgery or pegging. This review briefly discusses developments in implant design and aspects of design that affect function, but is not a detailed clinical review; rather, it aims to stimulate thought on optimal design and discusses recent developments. Novel technology in the form of a prototype device with a soft, biointegratable anterior surface is described as an example of newer approaches.


  • AlphaCor

    by Celia R Frcophth Hicks, Geoffrey J Franzco Crawford, John K. G Frcophth Dart, Günther Grabner, Edward J Holland, R Doyle Stulting, Donald T Frcophth Tan, Max Bulsara

    Purpose: To study the outcomes of AlphaCor implantation. Methods: The AlphaCor artificial cornea is indicated for corneal blindness not treatable by donor grafting. Prospective preoperative and follow-up data were collected. Data were evaluated using SPSS for statistical analysis of outcomes, trends, and associations. Results: This report includes data returned through February 28, 2006, for all 322 devices implanted, with mean follow-up in situ of 15.5 months and a maximum of 7.4 years. The probability of AlphaCor retention at 6 months and 1 and 2 years for protocol cases was 92%, 80%, and 62%, respectively, and off-label cases were at higher risk (P = 0.010), as were cases not prescribed medroxyprogesterone (MPG; P = 0.001). Currently, the most common complications were stromal melting, fibrous reclosure of the posterior lamellar opening, and white intraoptic deposits, with incidences in 2005 of 11.4%, 5.1%, and 2.6%, respectively. MPG seems to protect against melts, and eyes with a history of herpetic keratitis were not at increased risk. A history of glaucoma or the presence of tubes did not affect device retention. Complications culminated in loss of an eye in 1.3%. Mean preoperative visual acuity (VA) was hand movements. The VA achieved postoperatively (light perception to 20/20) was affected by previous pathology and postoperative course, with a mean improvement of 2 lines. Conclusion: AlphaCor provides a treatment option where a donor tissue graft would not succeed in severe corneal conditions, while being reversible to a donor graft in the event of complications for anatomic integrity. Surgical technique and adjunctive therapies are evolving with experience. Continued data collection is important for a fuller understanding of AlphaCor's role.


  • Open Access

    PHEMA as a keratoprosthesis material

    by C R Hicks, T V Chirila, S Vijayasekaran, G J Crawford

    PHEMA (poly(2-hydroxyethyl methacrylate) is a non-toxic polymer of the toxic monomer HEMA, though cytotoxicity is still possible if non-reacted monomer has not been fully removed. The “polyhydroxyethyl methacrylate” the authors obtained for their study was not fully described, and may have been contact lens blanks, unlikely to have been processed for “implantable quality.” Whether the samples had been fully extracted was not stated, nor was the hydration of the samples when used for the study. Contact lens blanks are not designed for cell adhesion and the results of this study, with regard to PHEMA, are entirely predictable and have been previously reported.


  • Histology of AlphaCor Skirts

    by C R Hicks, L Werner, S Vijayasekaran, N Mamalis, D J Apple

    To report histologic findings in 14 AlphaCor artificial corneas implanted during clinical trials and subsequently explanted from human subjects following complications, so as to evaluate biointegration within the device skirt. Explants were fixed and sectioned in paraffin. Histologic findings related to the device skirt were compared with earlier histologic results from animal studies and correlated with clinical histories. Two devices had been removed due to complications related to the optic alone, 11 following stromal melting overlying the biointegratable sponge skirt and 1 due to a retroprosthetic membrane. All devices demonstrated normal skirt porosity. Biointegration was similar to that found in animal studies but qualitatively appeared reduced in the affected areas in patients with overlying stromal melting prior to explantation. Patients with a longer history of melting prior to explantation demonstrated presence of inflammatory cells around the device. Histologic findings of the AlphaCor skirt in humans are consistent with earlier animal studies. This study confirms that biointegration by host fibroblastic cells, with collagen deposition occurs after AlphaCor implantation in humans. In cases in which stromal melting had occurred, biointegration is seen to be reduced. On correlating preoperative clinical factors with biointegration observed histologically, preoperative vascularization appears not to be required for AlphaCor biointegration.


  • Retroprosthetic Membranes in AlphaCor Patients

    by Celia R Frcophth Hicks, Stephen Hamilton

    Purpose: To report retroprosthetic membrane (RPM) formation in association with AlphaCor and identify risk factors for their formation and strategies for prevention and management. Methods: Review of AlphaCor data and case histories and literature review. Results: RPMs occurred with AlphaCor in 14 (9.3%) cases. We find significant associations with systemic risk factors (race, hypertension, diabetes mellitus) rather than ocular history, but perioperative management may also be related to risk of RPM development. Histology demonstrates a fibrovascular tissue resembling scarred corneal tissue. Similar histologic findings have been reported for other devices. Conclusion: Retrocorneal membranes and RPMs with earlier keratoprostheses have frequently been reported without specific identifiable causes. Diabetes is known to be associated with intraocular membrane formation. This study demonstrates that systemic factors affect the risk of RPM formation with AlphaCor. In cases identified as at greater risk of membrane formation, peri- and postoperative therapies such as steroids, non-steroidals, heparin or rTPA should be considered. In our series, several therapeutic and surgical strategies appear effective but recognizing patients at increased risk pre-operatively and using preventive measures where indicated is likely to be key to minimizing the incidence of this complication.


  • A Risk Score as Part of an Evidence-Based Approach to the Selection of Corneal Replacement Surgery

    by Celia R Hicks, Olivia MacVie, Geoffrey J Crawford, Ian J Constable

    There is currently no standardized methodology that permits preoperative prediction of the surgical technique or drug regimen for corneal grafting most likely to succeed for an individual patient. A score factor related to the chance of successful penetrating keratoplasty (PK) may assist in standardization of graft outcome reporting and evidence-based management. The Risk Score (RS) is based on factors shown to reduce the probability of 1-year survival of conventional PK in increments, using published Australian Corneal Graft Registry data. To asses its validity, Kaplan-Meier survival curves from 156 corneal replacement surgeries, stratified by preoperative RS, were used to derive the probability of survival at 1 year for donor PK, with or without systemic immunosuppression, and for synthetic PK with the AlphaCor™ artificial cornea. The probability of survival was then plotted against RS for each regimen, producing a family of curves. The mean RS for immunosuppressed cases was higher than for nonimmunosuppressed cases. The AlphaCor group had the highest scores. AlphaCor survival is little affected by the factors that affect the risk of graft survival, whereas the probability of donor graft survival, immunosuppressed or not, is inversely related to RS. This study was designed to test a method that allows objective comparison of outcomes of different methods of corneal replacement for different risk categories. Analysis of this small dataset supports the validity of the concept and suggests that the Risk Score is a useful descriptive statistic. With a sufficient sample size, statistically significant evidence of the optimum management method for an individual patient with a particular risk profile could be determined such that a prospective patient's preoperative RS could be used to assist management decisions. In particular, data allowing separation of different immunosuppression regimes would be useful. Functional outcomes such as visual acuity would be more significant clinically than the survival end point used in this study and the system also could be adapted to different follow-up periods.


  • Two cases of AlphaCor surgery performed using a small incision technique

    by Geoffrey J Crawford, Hiroshi Eguchi, Celia R Hicks

    The authors have evaluated the AlphaCor artificial cornea (previously Chirila KPro) in human patients since 1998, utilizing an intrastromal technique requiring extensive corneal lamellar dissection and recommending conjunctival flaps in all cases. Recent availability of low‐profile instruments has facilitated a simpler technique, which was first evaluated in two subjects followed for over 1 year prior to recommending the technique for wider adoption. The new technique is presented and illustrated herein, and its benefits and limitations compared with the traditional AlphaCor implantation are discussed.


  • Deposits in artificial corneas: risk factors and prevention

    by Celia R Hicks, Traian V Chirila, Liliana Werner, Geoffrey J Crawford, David J Apple, Ian J Constable

    Purpose: To identify risk factors for calcium deposition and pigmented staining within AlphaCor artificial corneas. Methods: Retrospective analysis of data from 72 AlphaCor implantations was conducted. Histological analysis of explants was performed. Results: Eight cases of either intraoptic calcium or pigment deposition occurred in AlphaCor patients between 2.5 and 21 months after implantation. Four cases had diffuse white deposits, confirmed to be calcium and associated with prior coadministration of topical steroids and beta-blockers. The other four cases had brown deposits, associated with cigarette smoking and topical levobunolol. Conclusion: These findings led to changes in patient management protocols, surgeon training and patient information so as to minimize the risk of further occurrences. No further cases of white deposition have occurred after warning surgeons of the risk associated with certain topical therapy combinations. The risk of brown staining may be difficult to remove completely as it appears that environmental exposure to chemicals may cause deposition in addition to personal smoking habits and topical medications.


  • AlphaCor??? Cases

    by Celia R. Hicks, Geoffrey J. Crawford, Donald T. Tan, Grant R. Snibson, Gerard L. Sutton, Nicholas Downie, Tjahjono D. Gondhowiardjo, Dennis S.-C. Lam, Liliana Werner, David Apple, et al.

    To describe clinical outcomes after a novel type of corneal surgery, implantation of an artificial cornea, AlphaCor , and to evaluate outcomes in comparison with alternative keratoprostheses and high-risk grafts. Case reports and data from a noncontrolled clinical trial and a literature review. The probability of AlphaCor retention to 1 year is 80%. Postoperative best corrected visual acuity ranges from Perception Light to 20/30. The most significant complications are stromal melts and optic depositions, for both of which the main risk factors have been identified. Complications can be managed without loss of the eye. Results from the clinical trial period have helped to determine the indications and risk factors for AlphaCor surgery and to refine surgical techniques. Continued monitoring of outcomes as the series increases will allow a more accurate determination of comparative outcomes. The series provides preliminary evidence that AlphaCor may have a lower incidence of complications than traditional keratoprostheses and may prove to be preferable to a donor graft in high-risk cases.


  • Melting after Keratoprosthesis Implantation: The Effects of Medroxyprogesterone

    by Celia R. Hicks, Geoffrey J. Crawford

    This study was conducted to evaluate the effect of topical medroxyprogesterone (MPG) following KPro implantation in human subjects in whom donor tissue grafts had been contraindicated by high risk of failure. Outcomes of implantation of the Chirila KPro, now known as AlphaCor, were reviewed with respect to postoperative MPG therapy. Ten of 45 (22%) patients had received MPG for a period of 12 months, while 35/45 (78%) had not. MPG treatment was halted because the drug is not approved as an adjunctive treatment of KPro patients. The main outcome measures were the incidence and timing of corneal stromal melting and visual acuity. Of those untreated with MPG, 34% developed a melt (mean follow-up 9.7 months), whereas of those who received MPG, 60% developed a melt (mean follow-up 28.4 months). However, mean time to melt onset for untreated cases was 8.8 months, whereas mean time to melt onset for treated cases was 23.2 months. There is a statistically significant association between time to melt onset, where melts occurred, and MPG therapy (χ2 = 0.001). In both groups, melts were strongly associated with a history of ocular HSV, which represented 17.1% of untreated and 20% of treated cases and is now considered a contraindication for AlphaCor. Preoperative visual acuities were in the range Perception Light (PL)-Count Fingers (CF) in all cases, whereas mean best postoperative best corrected visual acuity was 20/200 (range PL-20/30) in untreated cases and was 20/120 [range Hand Movements (HM)–20/30)] in MPG-treated cases. Although MPG may not influence the underlying incidence of melt-related complications, which are likely to be associated with other risk factors especially HSV, it may have a protective effect with regard to melt onset and severity. Controlled studies would assist evaluation of its use in this indication.