Ability of non-invasive tear break-up time to determine tear instability in contact lens wearers
- 22 October 2021
- journal article
- research article
- Published by Springer Nature in International Ophthalmology
- Vol. 42 (3) , 959-968
Abstract
Purpose To evaluate the performance of precorneal and prelens non-invasive tear break-up time (NIBUT) measurements to determine tear instability in contact lens (CL) wearers. Methods In this study, 50 eyes of 25 CL wearers were evaluated. Precorneal first and average NIBUTs and fluorescein tear break-up time (FBUT) were measured before wearing CLs in the morning. Those with FBUT less than 10 s were considered to have tear instability. After wearing CL, first and average prelens NIBUTs were measured at the 30th minute. The receiver operating characteristic (ROC) curve was analyzed to evaluate the performance of NIBUT measurements in the diagnosis of tear instability. Results The FBUT value had a significant correlation with first and average precorneal NIBUT values (p < 0.001, r = 0.653 and p < 0.001, r = 0.628, respectively). The FBUT value had no correlation with the prelens first and average NIBUT values (p = 0.542 and p = 0.263, respectively). To understand the relationship between the precorneal and prelens NIBUT values measured by the automated method, their correlation was evaluated. There was no significant correlation between the precorneal and prelens NIBUTs (for all; p > 0.05). The area under curve (AUC) in ROC curve for the first and average precorneal NIBUTs were 0.842 (p < 0.001) and 0.810 (p < 0.001), respectively. The AUC values for the first and average prelens NIBUTs at the 30th minute of CL wear were 0.586 and 0.619, respectively (p = 0.317 and p = 0.166, respectively). Conclusions Precorneal NIBUT measurements may be useful in diagnosing tear instability. Prelens NIBUT values are not yet capable of adequately defining the tear film dynamics in CL wearers.Keywords
All Related Versions
This publication has 27 references indexed in Scilit:
- Noninvasive In Vivo Assessment of Soft Contact Lens Type on Tear Film Surface QualityInvestigative Ophthalmology & Visual Science, 2012
- Combined Blockade of VEGFR-3 and VLA-1 Markedly Promotes High-Risk Corneal Transplant SurvivalInvestigative Ophthalmology & Visual Science, 2011
- Noninvasive Assessment of Tear Stability with the Tear Stability Analysis System in Tear Dysfunction PatientsInvestigative Ophthalmology & Visual Science, 2011
- Objective clinical performance of ‘comfort-enhanced’ daily disposable soft contact lensesContact Lens and Anterior Eye, 2010
- Clinical Tests for Successful Contact Lens Wear: Relationship and Predictive PotentialOptometry and Vision Science, 2008
- The Definition and Classification of Dry Eye Disease: Report of the Definition and Classification Subcommittee of the International Dry Eye Workshop (2007)The Ocular Surface, 2007
- Frequency of and Factors Associated With Contact Lens Dissatisfaction and DiscontinuationCornea, 2007
- The effect of short term contact lens wear on the tear film and ocular surface characteristics of tolerant and intolerant wearersContact Lens and Anterior Eye, 2006
- Soft contact lens wear in Hong Kong‐Chinese: predicting success*Ophthalmic and Physiological Optics, 2000
- Basic principles of ROC analysisSeminars in Nuclear Medicine, 1978