Chronic Failure of a Lumbar Total Disc Replacement with Osteolysis
Authors:
- 1 October 2008
- journal article
- case report
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 90 (10) , 2230-2234
Abstract
There has been extensive research and development into the use of motion-preserving technology to treat degenerative disc disease in the hope that it will provide a more functional range of motion and decrease adjacent-level disease associated with arthrodesis surgery. Recent reports with short-term follow-up have demonstrated both equivalent and favorable clinical results of total disc arthroplasty in comparison with lumbar arthrodesis surgery1-3. Despite the current use in patients, there is still a paucity of data on long-term outcome associated with the use of these devices. The few existing studies that have had a longer duration of follow-up have provided conflicting information, with some demonstrating overwhelming success4 and others demonstrating multiple complications and a less-than-desirable outcome5,6. Experimental disc designs such as the AcroFlex (DePuy Spine, Raynham, Massachusetts) have demonstrated the difficulty of transitioning from in vitro to in vivo success. A pilot study that was published in 1993 detailed the results for six patients who had been managed with an AcroFlex disc7. In 1990, the United States Food and Drug Administration (FDA) expressed concern regarding the potential carcinogenicity of the benzene-based solvents used to vulcanize the rubber core8. In the present report, we describe the nineteen-year follow-up results for one of the original six patients who had received a first-generation AcroFlex disc replacement7. To our knowledge, the present report represents the longest-term follow-up on the results of total disc arthroplasty in the literature. This case is of particular interest because the short-term outcome for this patient was rated as “good” in the original 1993 publication7. The patient was informed that data concerning the case would be submitted for publication, and he consented. A fifty-year-old man presented to the orthopaedic spine clinic in March 2007 …Keywords
This publication has 16 references indexed in Scilit:
- Survival and clinical outcome of SB Charité III disc replacement for back painThe Journal of Bone and Joint Surgery. British volume, 2007
- Results of the Prospective, Randomized, Multicenter Food and Drug Administration Investigational Device Exemption Study of the ProDisc®-L Total Disc Replacement Versus Circumferential Fusion for the Treatment of 1-Level Degenerative Disc DiseaseSpine, 2007
- Long-term Results of One-Level Lumbar ArthroplastySpine, 2007
- Release of Cobalt and Chromium Ions Into the Serum Following Implantation of the Metal-on-Metal Maverick-Type Artificial Lumbar Disc (Medtronic Sofamor Danek)Spine, 2007
- Polyethylene Wear Debris and Long-term Clinical Failure of the Charité Disc ProsthesisSpine, 2007
- Charité total disc replacement—clinical and radiographical results after an average follow-up of 17 yearsEuropean Spine Journal, 2005
- A Prospective, Randomized, Multicenter Food and Drug Administration Investigational Device Exemptions Study of Lumbar Total Disc Replacement With the CHARITÉ™ Artificial Disc Versus Lumbar FusionSpine, 2005
- Critical Analysis of Trends in Fusion for Degenerative Disc Disease Over the Past 20 YearsSpine, 2004
- Why Are Total Knee Arthroplasties Failing Today?Clinical Orthopaedics and Related Research, 2002
- Results of Disc Prosthesis After a Minimum Follow-Up Period of 2 YearsSpine, 1996