An anatomo‐functional implant positioning technique with robotic assistance for primary TKA allows the restoration of the native knee alignment and a natural functional ligament pattern, with a faster recovery at 6 months compared to an adjusted mechanical technique
- 13 May 2022
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (4) , 1334-1346
Abstract
Purpose: An anatomo‐functional implant positioning (AFIP) technique in total knee arthroplasty (TKA) could restore physiological ligament balance (symmetric gap in extension, asymmetric gap in flexion). The purposes were to compare (1) ligament balancing in extension and flexion after TKA in the AFIP group, (2) TKA alignment, implant positioning and patellar tracking between AFIP and adjusted mechanical alignment (aMA) techniques, (3) clinical outcomes between both groups at 12 months.Methods: All robotic‐assisted TKA with an AFIP technique were included (n = 40). Exclusion criteria were genu valgum (HKA angle > 183°), extra‐articular deformity more than 10°, and patellar maltracking (high‐grade J‐sign). One control patient with a TKA implanted by an aMA technique was matched for each case, based on age, body mass index, sex, and knee alignment. Ligament balancing (medial and lateral gaps in millimeters) in full extension and at 90° of flexion after TKA in the AFIP group was assessed with the robotic system. TKA alignment (HKA angle), implants positioning (femoral and tibial coronal axis, tibial slope, joint‐line orientation), patellar tracking (patellar tilt and translation) and the Knee Society Score (KSS) at 6 and 12 months were compared between both groups. The ligament balancing was compared using a t test for paired samples in the AFIP group. The radiographic measurements and KSS scores were compared between groups using a t test for independent samples.Results: In the AFIP group, there was no significant difference between the medial and lateral gap laxity in extension (NS). A significant opening of the lateral gap was observed in flexion compared to extension (mean: + 2.9 mm; p < 0.0001). The mean postoperative HKA angle was comparable between both groups (177.3° ± 2.1 in the AFIP group vs 176.8° ± 3.2; NS). In the AFIP group, the femoral anatomy was restored (90.9° ± 1.6) and the tibial varus was partially corrected (87.4° ± 1.8). The improvement of Knee and Function KSS at 6 months was better in the AFIP group (59.3 ± 11.9 and 51.7 ± 20, respectively, versus 49.3 ± 9.7 and 20.8 ± 13; p < 0.001).Conclusion: The AFIP concept allowed the restoration of the native knee alignment and a natural functional ligament pattern. With a more physiological target for ligament balancing, the AFIP technique had equivalent clinical outcomes at 12 months compared to aMA, with a faster recovery.Level of evidence: III retrospective therapeutic case control series.Keywords
This publication has 53 references indexed in Scilit:
- Constitutional Varus Does Not Affect Joint Line Orientation in the Coronal PlaneClinical Orthopaedics and Related Research, 2014
- Correlation of posterior tibial slope with metaphysiodiaphyseal angle in total knee arthroplasty: A radiological studyIndian Journal of Orthopaedics, 2013
- The Chitranjan Ranawat Award: Is Neutral Mechanical Alignment Normal for All Patients?: The Concept of Constitutional VarusClinical Orthopaedics and Related Research, 2012
- In vivo length patterns of the medial collateral ligament during the stance phase of gaitKnee Surgery, Sports Traumatology, Arthroscopy, 2010
- In vitro study of inter-individual variation in posterior slope in the knee jointClinical Biomechanics, 2009
- Patient-reported Outcome Correlates With Knee Function After a Single-design Mobile-bearing TKAClinical Orthopaedics and Related Research, 2008
- Determinants of patellar tracking in total knee arthroplastyClinical Biomechanics, 2008
- Asymmetry of mediolateral laxity of the normal kneeJournal of Orthopaedic Science, 2006
- Kinematics of the Human Knee Using an Open Chain Cadaver ModelClinical Orthopaedics and Related Research, 2003
- Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2002