Correlation Between EUT Failure Levels and ESD Generator Parameters
Authors:
- Qing CaiQCQing Cai
- Kai WangKWKai Wang
- John MaasJMJohn Maas
- Takehiro TakahashiTTTakehiro Takahashi
- Andrew MartwickAMAndrew Martwick
- David PommerenkeDPDavid Pommerenke
- 7 November 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 50 (4) , 794-801
Abstract
Some system-level electrostatic discharge (ESD) tests repeat badly if different ESD generators are used. For improving repeatability, ESD generator specifications have been changed, and modified generators have been compared in a worldwide round robin test. The test showed up to 1 : 3 variations of failure levels. Multiple parameters that characterize ESD generators have been measured. This paper correlates the parameters to test result variations trying to distinguish between important and nonrelevant parameters. The transient fields show large variations among different ESD generators. A correlation has been observed in many equipment under tests (EUTs) between failure levels and the spectral content of the voltage induced in a semicircular loop. EUT resonance enhances the field coupling, and is the dominate failure mechanism. The regulation on the transient field is expected to improve the test repeatability.Keywords
This publication has 14 references indexed in Scilit:
- Numerical Prediction and Measurement of ESD Radiated Fields by Free-Space Field SensorsIEEE Transactions on Electromagnetic Compatibility, 2007
- Evaluation of Falling Time Restriction of ESD Immunity Test Current Waveform: The Result of IEC 61000-4-2 Round Robin Test in Japan2007
- Measurements of ESD HBM events, simulator radiation and other characteristics toward creating a more repeatable simulation or; simulators should simulate2005
- Characterization of Human MetalESDReference Discharge Event and CorrelationofGenerator Parameters to Failure Levels—Part I: Reference EventIEEE Transactions on Electromagnetic Compatibility, 2004
- Characterization of Human Metal ESD Reference Discharge Event and Correlation of Generator Parameters to Failure Levels—Part II: Correlation of Generator Parameters to Failure LevelsIEEE Transactions on Electromagnetic Compatibility, 2004
- Some fundamental aspects of ESD testing2002
- Metrology and methodology of system level ESD testing2002
- ESD: waveform calculation, field and current of human and simulator ESDJournal of Electrostatics, 1996
- ESD: transient fields, arc simulation and rise time limitJournal of Electrostatics, 1995
- Fields radiated by electrostatic dischargesIEEE Transactions on Electromagnetic Compatibility, 1991