Correlation Between EUT Failure Levels and ESD Generator Parameters

Authors:
  • QCQing Cai
    Qing Cai
  • KWKai Wang
    Kai Wang
  • JMJohn Maas
    John Maas
  • TTTakehiro Takahashi
    Takehiro Takahashi
  • AMAndrew Martwick
    Andrew Martwick
  • DPDavid Pommerenke
    David Pommerenke

Abstract
Some system-level electrostatic discharge (ESD) tests repeat badly if different ESD generators are used. For improving repeatability, ESD generator specifications have been changed, and modified generators have been compared in a worldwide round robin test. The test showed up to 1 : 3 variations of failure levels. Multiple parameters that characterize ESD generators have been measured. This paper correlates the parameters to test result variations trying to distinguish between important and nonrelevant parameters. The transient fields show large variations among different ESD generators. A correlation has been observed in many equipment under tests (EUTs) between failure levels and the spectral content of the voltage induced in a semicircular loop. EUT resonance enhances the field coupling, and is the dominate failure mechanism. The regulation on the transient field is expected to improve the test repeatability.

This publication has 14 references indexed in Scilit: