Arteriovenous Fistula Creation Using the Optiflow™ Vascular Anastomotic Connector: The Open (Optiflow PatEncy and MaturatioN) Study
- 9 November 2013
- journal article
- clinical trial
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 15 (1) , 38-44
Abstract
Purpose: Arteriovenous fistulas (AVFs) are the preferred form of vascular access for hemodialysis. However, non-maturation and patency are major clinical problems. The Optiflow™ device is an implantable anastomotic connector used to standardize the creation of an AVF. Studies have suggested that the geometry of the anastomosis and experience of the surgeon impact patency and maturation rates. The Optiflow serves as a surgical template whereby the geometry and flow path of the anastomosis are predetermined. This prospective study was intended to evaluate maturation, patency and safety of the Optiflow. Methods: Forty-one upper arm AVFs were created in 41 end-stage renal disease patients using the Optiflow device at two investigational sites. Patients were followed for 90 days with serial Doppler ultrasounds performed at approximately 14, 42 and 90 days to determine AVF maturation. The primary performance endpoint was unassisted maturation, defined as an outflow vein that was equal to or greater than 5 mm in diameter, and with flow equal to or greater than 500 mL/min without the need for any intervention intended to promote or maintain maturation. The primary safety endpoint was the rate of device-related serious adverse events. Results: Unassisted maturation rates were 76%, 72% and 68% and unassisted patency rates were 93%, 88% and 78%, at 14, 42 and 90 days, respectively. There were no device-related serious adverse events. Conclusions: The results suggest that the Optiflow is safe for its intended use and could play an important role in enhancing AVF maturation while standardizing the anastomotic technique.Keywords
This publication has 28 references indexed in Scilit:
- Advances and New Frontiers in the Pathophysiology of Venous Neointimal Hyperplasia and Dialysis Access StenosisAdvances in Chronic Kidney Disease, 2009
- Facility Hemodialysis Vascular Access Use and Mortality in Countries Participating in DOPPS: An Instrumental Variable AnalysisAmerican Journal of Kidney Diseases, 2009
- Pre-Operative Vessel Mapping and Early Post-Operative Surveillance Duplex Scanning of Arteriovenous FistulaeThe Journal of Vascular Access, 2009
- Effect of Clopidogrel on Early Failure of Arteriovenous Fistulas for HemodialysisJAMA, 2008
- Neointimal Hyperplasia in Early Arteriovenous Fistula FailureAmerican Journal of Kidney Diseases, 2007
- Early Arteriovenous Fistula FailureClinical Journal of the American Society of Nephrology, 2006
- Vascular Access in Hemodialysis: Issues, Management, and Emerging ConceptsCardiology Clinics, 2005
- Novel Therapies for Hemodialysis Vascular Access Dysfunction: Fact or Fiction!Blood Purification, 2004
- Interventional Nephrology and Dialysis: The Initial Creation of Native Arteriovenous Fistulas: Surgical Aspects and Their Impact on the Practice of NephrologySeminars in Dialysis, 2003
- Effect of preoperative sonographic mapping on vascular access outcomes in hemodialysis patientsKidney International, 2001