MNMilind Nikam

Milind Nikam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Milind Nikam has a total of 339 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Success in Achieving Relatively High Targeted Convection Volumes in Multi‐Ethnic Individuals Receiving Hemodiafiltration in Singapore

    by Cindy Chan, Sugandha Saxena, Yan Yi Cheung, Nandakumar Mooppil, Akira Wu, Luca Neri, Jeffrey L. Hymes, Franklin W. Maddux, Benjamin E. Hippen, Milind Nikam

    Background: Hemodiafiltration has demonstrated improved outcomes in end‐stage kidney disease, particularly with higher convection volumes than conventional hemodialysis. However, data on multiethnic Asian populations remain limited. This study evaluated the feasibility of achieving relatively high targeted convection volumes in hemodiafiltration in patients with end‐stage kidney disease in Singapore. Methods: This retrospective cohort analysis included 1404 patients undergoing hemodiafiltration between 2019 and 2023 at Fresenius Kidney Care clinics in Singapore using data obtained from the EuCliD database. Patients aged ≥ 18 years and on hemodiafiltration for > 3 months were included. Multivariate regression models were used to assess the factors associated with the attainment of convection volume. Results: Over 291,000 hemodiafiltration sessions were analyzed. The mean convection volumes achieved were 21.8 L in post‐dilution and 40.8 L in pre‐dilution mode. Higher blood flow rates and treatment durations were significantly associated with relatively high targeted convection volume ( p < 0.001). The distribution of convection volume was similar among Chinese, Indian, and Malay patients. Ethnicity, age, and vascular access were not significant predictors. Approximately 29% of the variation in achieved convection volume was attributable to center‐related factors. Conclusion: Relatively high targeted convection volume in hemodiafiltration was consistently achieved across a multiethnic cohort in Singapore. These findings support the feasibility of delivering high‐volume hemodiafiltration to diverse real‐world settings.


  • Outcomes of a nephrologist-driven tunnelled dialysis catheter insertion service in South East Asia

    by Milind Nikam, Claude J. Renaud, Joshua Shaowen Lee, Sri Fairuz B. Saifful, Allen Yan Lun Liu, Eng Kuang Lim, Ying Ying Seow, Lee Ying Yeoh

    Introduction: Tunnelled dialysis catheters (TDCs) are being increasingly inserted by nephrologists globally but there is limited experience and paucity of published outcomes data from South-East Asia (SEA). This study was conducted to analyse the outcomes of TDC insertion by nephrologists from a single centre in SEA. Methods: All patients who underwent TDC insertion by nephrologists from October 2013 to June 2016 were included. TDC survival was calculated using Kaplan-Meier survival method. Impact of variables was assessed using Cox proportional hazards model. Results: A total of 344 TDCs were inserted in 274 patients. The most common indication was haemodialysis initiation (60.2%) followed by existing catheter dysfunction (CD) (12.2%), failed vascular access (10.2%) and catheter-related bacteraemia (CRB) (9.9%). Insertion was successful in 97% patients. The most common location was the right internal jugular vein (87%). The cumulative survival for all TDCs inserted, as defined by the time to non-elective removal of a TDC, at 3, 6 and 9 months was 83%, 61%, and 44%, respectively. Median catheter survival was 231 days. Common indications for removal were CD (13.4%) and CRB or suspected infection (12.5%). Common complications were bleeding (8.72%), infection (13.7%) and CD (16.5%). Median time to infection was 103 days. In multivariate analysis, male gender was associated with poor catheter survival, for primary insertions (p = 0.015, HR 0.62) and diabetes was associated with TDC infection (p = 0.024, OR 1.1). Conclusions: This is one of the first reports of TDC insertion by nephrologists from SEA. Our outcomes compare favourably with those reported in the literature.


  • Open Access

    Long-term outcomes of persistent disease and relapse in primary membranous nephropathy

    by Durga A.K. Kanigicherla, Colin D. Short, Stephen A. Roberts, Patrick Hamilton, Milind Nikam, Shelley Harris, Paul E.C. Brenchley, Michael C. Venning

    Primary membranous nephropathy is associated with variable clinical course ranging from spontaneous remission to slow progression to end stage renal failure. Achieving remission confers better renal survival in primary membranous nephropathy (PMN). Longer term outcomes such as patient survival and relapse of active disease remain poorly understood. We performed a retrospective study of 128 consecutive adult patients diagnosed with biopsy proven PMN at a single UK centre between 1980 and 2010. These patients were followed prospectively over a median of 128 months. We assessed impact of persistent disease and relapse on Stage 5 chronic kidney disease (CKD-5) and patient survival and present longer term cumulative incidences of different end points. One hundred patients achieved partial remission (PartRem) and 28 patients did not achieve remission (NoRem). Nine per cent of patients achieving first remission developed CKD-5 and 75% of those with NoRem developed CKD-5 [hazard ratio (HR) 0.07, 95% confidence interval 0.03–0.19). Relapse following PartRem occurred in 31 patients (31%) during follow-up and was significantly associated with progression to CKD-5. Progression to CKD-5 was strongly associated with death (47 versus 6%, HR 23.4; P < 0.01). Cumulative incidence at 15 years following first presentation included: death, 14%; CKD-5, 28%; and relapse 40% (in patients who achieved first remission). Our data strongly suggest that mortality in PMN is seen in patients with disease progression to CKD-5. Achieving remission is strongly associated with improved renal survival after first presentation and following relapse. We suggest that patients who achieve remission should be followed up in longer term, and better strategies to help improve outcomes are needed in clinical practice.


  • Prospective controlled pilot study of arteriovenous fistula placement using the novel Optiflow device

    by Milind Nikam, Eric Solomon Chemla, Jackie Evans, Angela Summers, Paul Brenchley, Afshin Tavakoli, Prabir Roy-Chaudhury, Sandip Mitra


  • Open Access

    Acute Arteriovenous Access Failure: Long-Term Outcomes of Endovascular Salvage and Assessment of Co-Variates Affecting Patency

    by Milind D. Nikam, James Ritchie, Anu Jayanti, Ondina A. Bernstein, Leonard Ebah, Paul Brenchley, Alastair Hutchison, Nicholas Chalmers, Sandip Mitra, Milind D Nikam

    Aims: This study reports long-term outcomes after endovascular salvage (EVS) for acute dialysis fistula/graft dysfunction. Methods: All patients presenting with acute fistula or graft dysfunction, excluding primary failures, referred for endovascular salvage were included in this single-centre prospective study. Results: Altogether, 410 procedures were carried out in 232 patients. Overall, the incidence of thrombosis/occlusion (per patient-year) was 0.12 for fistulae and 0.9 for grafts. The anatomical success rate for EVS was 94% for fistulae and 92% for grafts. Primary patency rates for fistulae at 1, 6, 12, 24 and 36 months were 82, 64, 44, 34 and 26%, respectively, whereas secondary patency rates were 88, 84, 74, 69 and 61%, respectively. Primary patency rates for grafts at 1, 6 and 12 months were 50, 14 and 8%. The overall rate of complications was 6% with no incidence of symptomatic pulmonary embolism. In a Cox regression model, upper-arm location of fistula (HR 1.9, p = 0.04, n = 144) was associated with lower primary patency, whereas the presence of thrombosis was associated lower primary (HR 1.9, p = 0.004, n = 144) and secondary patency (HR 3.7, p < 0.001, n = 144). Aspirin therapy was associated with longer primary patency (HR 0.6, p = 0.02, n = 144) and secondary patency (HR 0.58, p = 0.08, n = 144). Conclusion: EVS is effective but longer-term outcomes are poor. Presence of thrombosis portends poor fistula survival and strategies for prevention need attention. Balloon maceration, our preferred declotting technique, is safe and the most cost-effective method. Aspirin therapy for patients presenting with failure of fistulae deserves further investigation.


  • Open Access

    Medication burden in CKD-5D: impact of dialysis modality and setting

    by Kathrine Parker, Milind Nikam, Anuradha Jayanti, Sandip Mitra

    Medication adherence is thought to be around 50% in the general and dialysis population. Reducing the pill burden (PB) reduces regime complexity and can improve adherence. Increased adherence should lead to improvement in treatment outcomes and patient quality of life. There is currently little published data on PB in CKD-5D across dialysis modalities. This is a retrospective, single renal network study. All in-centre HD (MHD), peritoneal dialysis (PD) and home HD (HHD) patients were identified in the Greater Manchester East sector renal network. Information collected included age, sex, comorbidities, daily PB, dialysis vintage and adequacy. Data were retrieved from a customized renal database, clinic and discharge letters with cross validation from the general practitioner when needed. Two hundred and thirty-six prevalent dialysis patients were studied. HHD patients had a significantly lower PB (11 ± 7 pills/day) compared with PD and MHD (16 ± 7 pills/day). The HHD patients required fewer BP medications to meet the recommended target. HD setting was the only significant factor for reducing PB. For home therapies (HHD versus PD), weekly Kt/v and serum phosphate were significant factors influencing PB. When comparing all modalities, OR of PB ≥ 15/day for MHD versus HHD was 3.9 and PD versus HHD was 4.9. The influence of HHD is dominant above factors such as comorbidities or clinical variables in reducing PB for MHD. Higher clearances achieved by HHD could explain differences in PB with PD. This is the first comparative study of PB across all dialysis modalities and factors that influence it. The PB advantage in HHD may result in greater adherence and might contribute to the outcome benefit often seen with this modality. Higher clearances achieved by HHD could explain differences in PB with PD but the precise reasons for lower PB remain speculative and deserve further research in larger settings.


  • Arteriovenous Fistula Creation Using the Optiflow™ Vascular Anastomotic Connector: The Open (Optiflow PatEncy and MaturatioN) Study

    by Eric Chemla, Afshin Tavakoli, Milind Nikam, Sandip Mitra, Tlou Malete, Jackie Evans, Prabir Roy-Chaudhury

    Purpose: Arteriovenous fistulas (AVFs) are the preferred form of vascular access for hemodialysis. However, non-maturation and patency are major clinical problems. The Optiflow™ device is an implantable anastomotic connector used to standardize the creation of an AVF. Studies have suggested that the geometry of the anastomosis and experience of the surgeon impact patency and maturation rates. The Optiflow serves as a surgical template whereby the geometry and flow path of the anastomosis are predetermined. This prospective study was intended to evaluate maturation, patency and safety of the Optiflow. Methods: Forty-one upper arm AVFs were created in 41 end-stage renal disease patients using the Optiflow device at two investigational sites. Patients were followed for 90 days with serial Doppler ultrasounds performed at approximately 14, 42 and 90 days to determine AVF maturation. The primary performance endpoint was unassisted maturation, defined as an outflow vein that was equal to or greater than 5 mm in diameter, and with flow equal to or greater than 500 mL/min without the need for any intervention intended to promote or maintain maturation. The primary safety endpoint was the rate of device-related serious adverse events. Results: Unassisted maturation rates were 76%, 72% and 68% and unassisted patency rates were 93%, 88% and 78%, at 14, 42 and 90 days, respectively. There were no device-related serious adverse events. Conclusions: The results suggest that the Optiflow is safe for its intended use and could play an important role in enhancing AVF maturation while standardizing the anastomotic technique.


  • Subcutaneous interstitial pressure and volume characteristics in renal impairment associated with edema

    by Leonard M. Ebah, Helge Wiig, Idalia Dawidowska, Charlotte O'Toole, Angela Summers, Milind Nikam, Anuradha Jayanti, Beatrice Coupes, Paul Brenchley, Sandip Mitra


  • Open Access

    Technique survival in home haemodialysis: a composite success rate and its risk predictors in a prospective longitudinal cohort from a tertiary renal network programme

    by Anuradha Jayanti, Milind Nikam, Leonard Ebah, Gill Dutton, Julie Morris, Sandip Mitra

    Resurgence of interest in home haemodialysis (HHD) is, in part, due to emerging evidence of the benefits of extended HD regimens, which are most feasibly provided in the home setting. Although specific HHD therapy established at home such as nocturnal HD (NHD) has been reported from individual programmes, little is known about overall HHD success. The study included 166 patients who were accepted in the Manchester (UK) HHD training programme through liberal selection criteria. All patients were followed up prospectively until a switch to alternative modality, to include 4528 patient-months of follow-up and about 81 508 HHD sessions during an 8-year period (January 2004–December 2011). Twenty-four patients switched to an alternative modality during the period. Combined technique survival (HHDc) as a composite of training (HHDtr) and at home (HHDhome) was analysed and clinical predictors of HHD modality failure since the commencement of the programme were calculated using Cox regression analysis. Technology-related interruptions to dialysis over a 12-month period and patient-reported reasons for quitting the programme were analysed. Technique survival at 1, 2 and 5 years was 90.2, 87.4, 81.5% (HHDc) and 98.4, 95.4 and 88.9% (HHDhome) when censored for training phase exits, death and transplantation. The combined HHDc modality switch rate is 1 in 192 patient-months of dialysis follow-up. Age >60 years, diabetes, cardiac failure, unit decrease in Hb and increasing score of age-adjusted Charlson­-comorbidity index were significantly associated with technique failure. Significant clinical predictors of HHD technique failure in a multivariate model were diabetes (P = 0.002) and cardiac failure (P = 0.05). The majority (61%) switched to an alternative modality for non-medical reasons. The composite of operator error and mechanical breakdown resulting in temporary HHD technique failure was 0.7% per year. HHD training and technique failure rate are low. Technical errors are infrequent too. Diabetes and cardiac failure are associated with significant risk of technique failure. Although absolute rates are low, training failure is proportionally quite significant, highlighting the importance of reporting the composite technique failure rate (to include early HHD training phase) in HHD programmes.


  • Top Cited Papers

    Anti-PLA2R antibodies measured by ELISA predict long-term outcome in a prevalent population of patients with idiopathic membranous nephropathy

    by Durga Kanigicherla, Jennet Gummadova, Edward A. McKenzie, Stephen A. Roberts, Shelley Harris, Milind Nikam, Kay Poulton, Lorna McWilliam, Colin D. Short, Michael Venning, et al.