Comparison of PDMS and NOA Microfluidic Chips: Deformation, Roughness, Hydrophilicity and Flow Performance
Open Access
- 31 October 2023
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 14 (11) , 2033
Abstract
Microfluidic devices are frequently manufactured with polydimethylsiloxane (PDMS) due to its affordability, transparency, and simplicity. However, high-pressure flow through PDMS microfluidic channels lead to an increase in channel size due to the compliance of the material. As a result, longer response times are required to reach steady flow rates, which increases the overall time required to complete experiments when using a syringe pump. Due to its excellent optical properties and increased rigidity, Norland Optical Adhesive (NOA) has been proposed as a promising material candidate for microfluidic fabrication. This study compares the compliance and deformation properties of three different characteristic sized (width of parallel channels: 100, 40 and 20 µm) microfluidic devices made of PDMS and NOA. The comparison of the microfluidics devices is made based on the Young’s modulus, roughness, contact angle, channel width deformation, flow resistance and compliance. The experimental resistance is estimated through the measurement of the flow at a given pressure and a precision flow meter. The characteristic time of the system is extracted by fitting the two-element resistance-compliance (RC) hydraulic circuit model. The compliance of the microfluidics chips is estimated through the measurement of the characteristic time required for channels to achieve an output flow rate equivalent to that of the input flow rate using a syringe pump and a precision flow meter. The Young modulus was found to be 2 MPa for the PDMS and 1743 MPa for the NOA 63. The surface roughness was found to be higher for the NOA 63 than for the PDMS. The hydrophilicities of materials were found comparable with and without plasma treatment. The results show that NOA devices have lower compliance and deformation than PDMS devices.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (RGPIN-2020-07020)
This publication has 37 references indexed in Scilit:
- Contact angle study of blood dilutions on common microchip materialsJournal of the Mechanical Behavior of Biomedical Materials, 2013
- Velocity measurement accuracy in optical microhemodynamics: experiment and simulationPhysiological Measurement, 2012
- Plastic–PDMS bonding for high pressure hydrolytically stable active microfluidicsLab on a Chip, 2009
- Research on the cast molding process for high quality PDMS moldsMicroelectronic Engineering, 2009
- The deformation of flexible PDMS microchannels under a pressure driven flowLab on a Chip, 2008
- Effects of strain rate, mixing ratio, and stress–strain definition on the mechanical behavior of the polydimethylsiloxane (PDMS) material as related to its biological applicationsBiomedical Microdevices, 2008
- Cells on chipsNature, 2006
- Flow-induced deformation of shallow microfluidic channelsLab on a Chip, 2006
- Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic DevicesChemInform, 2002
- Physics and Applications of Microfluidics in BiologyAnnual Review of Biomedical Engineering, 2002