Tatiana Turcitu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tatiana Turcitu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Andy Vinh Le
Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, ON, K1N 6N5, Canada
1 shared publication- Andy Vinh Le
Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N 6N5, Canada
1 shared publication - Curtis J. K. Armstrong
Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N 6N5, Canada
1 shared publication Kyle Champagne
Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, ON, K1N 6N5, Canada
1 shared publicationMarianne Fenech
Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, ON, K1N 6N5, Canada
1 shared publication- Marianne Fenech
Department of Mechanical Engineering, University of Ottawa
1 shared publication
Latest Publications
- Open Access
- 5 February 2026
- Published by Elsevier in Microvascular Research
- Vol. 165, 104917
Dose-dependent effects of diamide and glutaraldehyde on red blood cell deformability, viscosity, and morphology
- 5 February 2026
- Published by Elsevier in Microvascular Research
- Vol. 165, 104917
Open AccessDose-dependent effects of diamide and glutaraldehyde on red blood cell deformability, viscosity, and morphology
- Open Access
- 31 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (11) , 2033
Comparison of PDMS and NOA Microfluidic Chips: Deformation, Roughness, Hydrophilicity and Flow Performance
Microfluidic devices are frequently manufactured with polydimethylsiloxane (PDMS) due to its affordability, transparency, and simplicity. However, high-pressure flow through PDMS microfluidic channels lead to an increase in channel size due to the compliance of the material. As a result, longer response times are required to reach steady flow rates, which increases the overall time required to complete experiments when using a syringe pump. Due to its excellent optical properties and increased rigidity, Norland Optical Adhesive (NOA) has been proposed as a promising material candidate for microfluidic fabrication. This study compares the compliance and deformation properties of three different characteristic sized (width of parallel channels: 100, 40 and 20 µm) microfluidic devices made of PDMS and NOA. The comparison of the microfluidics devices is made based on the Young’s modulus, roughness, contact angle, channel width deformation, flow resistance and compliance. The experimental resistance is estimated through the measurement of the flow at a given pressure and a precision flow meter. The characteristic time of the system is extracted by fitting the two-element resistance-compliance (RC) hydraulic circuit model. The compliance of the microfluidics chips is estimated through the measurement of the characteristic time required for channels to achieve an output flow rate equivalent to that of the input flow rate using a syringe pump and a precision flow meter. The Young modulus was found to be 2 MPa for the PDMS and 1743 MPa for the NOA 63. The surface roughness was found to be higher for the NOA 63 than for the PDMS. The hydrophilicities of materials were found comparable with and without plasma treatment. The results show that NOA devices have lower compliance and deformation than PDMS devices.
- 31 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (11) , 2033
Open AccessComparison of PDMS and NOA Microfluidic Chips: Deformation, Roughness, Hydrophilicity and Flow Performance
Microfluidic devices are frequently manufactured with polydimethylsiloxane (PDMS) due to its affordability, transparency, and simplicity. However, high-pressure flow through PDMS microfluidic channels lead to an increase in channel size due to the compliance of the material. As a result, longer response times are required to reach steady flow rates, which increases the overall time required to complete experiments when using a syringe pump. Due to its excellent optical properties and increased rigidity, Norland Optical Adhesive (NOA) has been proposed as a promising material candidate for microfluidic fabrication. This study compares the compliance and deformation properties of three different characteristic sized (width of parallel channels: 100, 40 and 20 µm) microfluidic devices made of PDMS and NOA. The comparison of the microfluidics devices is made based on the Young’s modulus, roughness, contact angle, channel width deformation, flow resistance and compliance. The experimental resistance is estimated through the measurement of the flow at a given pressure and a precision flow meter. The characteristic time of the system is extracted by fitting the two-element resistance-compliance (RC) hydraulic circuit model. The compliance of the microfluidics chips is estimated through the measurement of the characteristic time required for channels to achieve an output flow rate equivalent to that of the input flow rate using a syringe pump and a precision flow meter. The Young modulus was found to be 2 MPa for the PDMS and 1743 MPa for the NOA 63. The surface roughness was found to be higher for the NOA 63 than for the PDMS. The hydrophilicities of materials were found comparable with and without plasma treatment. The results show that NOA devices have lower compliance and deformation than PDMS devices.