Influence of exhaust hood geometry on the capture efficiency of lateral exhaust and push–pull ventilation systems in surface treatment tanks
- 25 September 2008
- journal article
- sustainability
- Published by Wiley in Environmental Progress
- Vol. 27 (3) , 405-411
Abstract
In a local exhaust ventilation system, where the pollutant or the emitted flows are captured near the generated source, the knowledge of the capture efficiency is necessary to evaluate performance. This article reports a study of the influence of the exhaust hood slot height on the capture efficiency. For this study, the emission of gases and vapors from open surface tanks used in industrial treatments has been simulated in an installation fitted with two ventilation systems: lateral exhaust and push–pull. Several configurations were possible by varying the geometrical and operational conditions. Both qualitative and quantitative evaluations have been performed, the former through observations of the flows using smoke and the latter by using sulfur hexafluoride as tracer gas. The results obtained on capture efficiency for both ventilation systems tested with several exhaust slot height and as a function of the operating flows rates, are presented. It was found that varying the exhaust slot height between 15 and 45 cm had no effect on capture efficiency. The results show that there are no significant differences between the exhaust slots heights tested, although, in the case of 60 cm for lateral exhaust ventilation, the efficiency was slightly lower. © 2008 American Institute of Chemical Engineers Environ Prog, 2008Keywords
This publication has 7 references indexed in Scilit:
- Local Ventilation Solution for Large, Warm Emission SourcesAnnals of Occupational Hygiene, 2006
- Aerodynamic Characteristics and Design Guidelines of Push–Pull Ventilation SystemsAnnals of Occupational Hygiene, 2004
- On the Inertial Range of Particles Under the Influence of Local Exhaust HoodsAnnals of Occupational Hygiene, 2003
- An analytical, numerical, and experimental comparison of the fluid velocity in the vicinity of an open tank with one and two lateral exhaust slot hoods and a uniform crossdraftAnnals of Occupational Hygiene, 2000
- An Analytical, Numerical, and Experimental Comparison of the Fluid Velocity in the Vicinity of an Open Tank with One and Two Lateral Exhaust Slot Hoods and a Uniform CrossdraftAnnals of Work Exposures and Health, 2000
- Air Movement Visualization in the Workplace: Current Methods and New ApproachesAIHA Journal, 2000
- An Overview of Push—Pull Ventilation CharacteristicsApplied Occupational and Environmental Hygiene, 1990