FMFrancisco Marzal

Francisco Marzal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Francisco Marzal has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • A. Baeza

    Universidad de Murcia, Departamento de Ingeniería Química, 30071 Espinardo, Murcia, Spain

    4 shared publications
  • A. Miñana

    Universidad de Murcia, Departamento de Ingeniería Química, 30071 Espinardo, Murcia, Spain

    4 shared publications
  • E. González

    Universidad de Murcia, Departamento de Ingeniería Química, 30071 Espinardo, Murcia, Spain

    3 shared publications
  • Agustín Miñana

    Departamento de Ingeniería Química, Universidad de Murcia, 30071 Espinardo, Murcia, España

    1 shared publication
  • Enrique González

    Departamento de Ingeniería Química, Universidad de Murcia, 30071 Espinardo, Murcia, España

    1 shared publication
  • Enrique González

    Universidad de Murcia, Departamento de Ingeniería Química, 30071 Espinardo, Murcia, Spain

    1 shared publication

Latest Publications

  • Influence of exhaust hood geometry on the capture efficiency of lateral exhaust and push–pull ventilation systems in surface treatment tanks

    by Enrique González, Francisco Marzal, Agustín Miñana, Marta Doval

    In a local exhaust ventilation system, where the pollutant or the emitted flows are captured near the generated source, the knowledge of the capture efficiency is necessary to evaluate performance. This article reports a study of the influence of the exhaust hood slot height on the capture efficiency. For this study, the emission of gases and vapors from open surface tanks used in industrial treatments has been simulated in an installation fitted with two ventilation systems: lateral exhaust and push–pull. Several configurations were possible by varying the geometrical and operational conditions. Both qualitative and quantitative evaluations have been performed, the former through observations of the flows using smoke and the latter by using sulfur hexafluoride as tracer gas. The results obtained on capture efficiency for both ventilation systems tested with several exhaust slot height and as a function of the operating flows rates, are presented. It was found that varying the exhaust slot height between 15 and 45 cm had no effect on capture efficiency. The results show that there are no significant differences between the exhaust slots heights tested, although, in the case of 60 cm for lateral exhaust ventilation, the efficiency was slightly lower. © 2008 American Institute of Chemical Engineers Environ Prog, 2008


  • Visualization of Airflows in Push-Pull Ventilation Systems Applied to Surface Treatment Tanks

    by F. Marzal, E. González, A. Miñana, A. Baeza

    A pilot installation was designed that simulates a surface treatment tank fitted with a push-pull ventilation system. The installation contained elements for measuring and controlling the operational variables (flow rate and tank temperature) and smoke generating equipment for injecting smoke through the holes of the push unit and from the tank surface. Visual observation and video recording of the flows involved meant it was possible to follow the qualitative behavior of the push flow rate along the tank surface and to identify any emissions not captured by the exhaust system. It was possible to differentiate the initial semifree push curtain, its impact with the tank surface, the wall jet that moved toward the exhaust, and its entrance into the exhaust. The methodology proposed is complemented by a quantitative technique for measuring the efficiency, using sulfur hexafluoride as tracer, which permits the causes and location of losses in the ventilation system to be determined.


  • Methodologies for Determining Capture Efficiencies in Surface Treatment Tanks

    by F. Marzal, E. González, A. Miñana, A. Baeza

    Methodologies are proposed for determining capture efficiencies in the ventilation systems of surface treatment tanks, using test-scale equipment. The equipment, which incorporates a lateral and push-pull ventilation system, can measure and control the variables of interest because it incorporates a tracer gas generator (sulfur hexafluoride, the concentration of which is measured by infrared spectrometer). The experimental methodologies described determine total efficiency (when the tracer is emitted uniformly from the whole surface of the tank) and the so-called transversal linear efficiency (when the tracer is emitted linearly through a perforated tube situated over the tank, parallel to the exhaust hood face). The analytical and graphical relationships that can be are established between the two efficiencies make it possible to detect where the emissions not captured by the ventilation system are produced (i.e., losses to the outside). At the same time, such losses can be quantified. Several experiments, results of which are analyzed by the methods described, are included.

  • Open Access

    Determination and Interpretation of Total and Transversal Linear Efficiencies in Push–Pull Ventilation Systems for Open Surface Tanks

    by F. Marzal, E. González, A. Miñana, A. Baeza

    A real-scale pilot installation simulating an open surface treatment tank with a push–pull ventilation system has been designed. From experiments carried out, typical representations of the total and transversal linear efficiencies show that when total efficiency is related to push flow rate, taking as a parameter the pull flow rate, a parabolic profile is obtained with a maximum point or plateau that increases as the pull flow increases. When the transversal linear efficiency is analysed, three general zones where losses occur to the exterior can be detected: (i) when the push flow rate is low, any distortion in the wall jet, whether external (e.g. in the air flow inside the workshop) or internal (e.g. thermal effects), provokes an escape from contaminant; (ii) in the impact zone, where the push flow impacts on the tank surface, distortion increases as the push flow rate increases; (iii) when the push/pull flow rate ratio increases and preferential currents are produced inside the exhaust hood, these escape and cause substantial losses in efficiency.


  • Analytical Model for Evaluating Lateral Capture Efficiencies in Surface Treatment Tanks

    by F. Marzal, E. González, A. Miñana, A. Baeza

    A pilot scale installation 1.8 m long and 1.6 m wide was designed to simulate a surface treatment tank incorporating a lateral capture system and a distribution network that permits the surface emission of tracer (SF6). The capture efficiency, ET, was determined as a function of the specific capture flow qc, m3/sm2, for three tank lengths, L, (1.2, 1.53, and 1.8 m) and several temperatures, T, from ambient to 95°C, keeping the surrounding air velocity low (v≤0.1 m/sec). The data showed a satisfactory fit to a model that related capture efficiency with two exponential functions: the first dependent on the ratio capture velocity/air velocity in the vicinity of the tank, and the second on the ratio capture velocity/velocity of rising drafts provoked by the temperature of the tank.