Impact of implant–abutment connection and positioning of the machined collar/microgap on crestal bone level changes: a systematic review
Authors:
Open Access
- 18 June 2013
- journal article
- review article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 25 (4) , 417-425
Abstract
Objectives: To address the following focused question: What is the impact of implant–abutment configuration and the positioning of the machined collar/microgap on crestal bone level changes?Material and methods: Electronic databases of the PubMed and the Web of Knowledge were searched for animal and human studies reporting on histological/radiological crestal bone level changes (CBL) at nonsubmerged one‐/two‐piece implants (placed in healed ridges) exhibiting different abutment configurations, positioning of the machined collar/microgap (between 1992 and November 2012: n = 318 titles). Quality assessment of selected full‐text articles was performed according to the ARRIVE and CONSORT statement guidelines.Results: A total of 13 publications (risk of bias: high) were eligible for the review. The weighted mean difference (WMD) (95% CI) between machined collars placed either above or below the bone crest amounted to 0.835 mm favoring an epicrestal positioning of the rough/smooth border (P < 0.001) (P‐value for heterogeneity: 0.885, I2: 0.000% = no heterogeneity). WMD (95% CI) between microgaps placed either at or below the bone crest amounted to −0.479 mm favoring a subcrestal position of the implant neck (P < 0.001) (P‐value for heterogeneity: 0.333, I2: 12.404% = low heterogeneity). Only two studies compared different implant–abutment configurations. Due to a high heterogeneity, a meta‐analysis was not feasible.Conclusions: While the positioning of the machined neck and microgap may limit crestal bone level changes at nonsubmerged implants, the impact of the implant–abutment connection lacks documentation.Keywords
Funding Information
- CAMLOG Foundation
- Basel
This publication has 46 references indexed in Scilit:
- The Effect of Internal Versus External Abutment Connection Modes on Crestal Bone Changes Around Dental Implants: A Radiographic AnalysisJournal of Periodontology, 2012
- Influence of Placement Depth on Bone Remodeling Around Tapered Internal Connection Implant: A Clinical and Radiographic Study in DogsJournal of Periodontology, 2012
- Preservation of crestal bone by implant design. A comparative study in minipigsClinical Oral Implants Research, 2012
- Equicrestal and Subcrestal Dental Implants: A Histologic and Histomorphometric Evaluation of Nine Retrieved Human ImplantsJournal of Periodontology, 2011
- Effect of different localizations of microgap on clinical parameters and inflammatory cytokines in peri-implant crevicular fluid: a prospective comparative studyClinical Oral Investigations, 2011
- Animal research: Reporting in vivo experiments: The ARRIVE guidelinesBritish Journal of Pharmacology, 2010
- Subcrestal placement of two‐part implantsClinical Oral Implants Research, 2009
- Influence of Interimplant Distances and Placement Depth on Papilla Formation and Crestal Resorption: A Clinical and Radiographic Study in DogsJournal of Oral Implantology, 2009
- Initial Implant Position Determines the Magnitude of Crestal Bone RemodelingJournal of Periodontology, 2004
- Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non‐Submerged and Submerged Implants in the Canine MandibleJournal of Periodontology, 2000