A Novel Minimally Occlusive Cuff Method Utilizing Ultrasound Vascular Imaging for Stress-Free Blood Pressure Measurement: A-Proof-of-Concept Study
- 15 August 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (4) , 934-945
Abstract
Objective: Occlusive cuff inflation in ambulatory blood pressure (BP) monitoring disturbs the daily life of the user, and affects efficacy of monitoring. To overcome this limitation, we have developed a novel minimally-occlusive cuff method for stress-free measurement of BP. This study aimed to experimentally evaluate the reliability of this method. Methods In this method, a thin-plate-type ultrasound probe placed between the cuff and the skin is used to measure the ultrasonic dimension of the artery. Analyzing the arterial dimension and the cuff pressure measured during mild cuff inflation (cuff pressure $\lt50$ mmHg) allows estimation of systolic ( $\rm SBP_e$ ) and diastolic BP ( $\rm DBP_e$ ). We evaluated this method in 6 anesthetized dogs by attaching the cuff with the probe to the right thigh to get $\rm SBP_e$ and $\rm DBP_e$ . We measured reference SBP and DBP using an intra-arterial catheter and determined the pulse arrival time (PAT) commonly employed in cuff-less BP monitoring. BP was perturbed by infusing noradrenaline or nitroprusside. Results: $\rm DBP_e$ correlated tightly with DBP with a coefficient of determination ( $\rm R^2$ ) of 0.85 ± 0.08, and predicted DBP with a bias of 3.9 ± 7.9 mmHg after a one-time calibration. Reciprocal of PAT correlated poorly with DBP ( $\rm R^2$ = 0.49 ± 0.17), and predicted DBP less accurately than this method. $\rm SBP_e$ correlated well with SBP ( $\rm R^2$ = 0.78 ± 0.08) Conclusion: This method reliably tracks BP changes without occlusive cuff inflation. Once calibrated, this method measures DBP accurately. Significance: This method has the potential for stress-free BP measurement in ambulatory BP monitoring.
Keywords
Funding Information
- JSPS KAKENHI (15K01307, 18K12126)
This publication has 30 references indexed in Scilit:
- Non-invasive continuous arterial pressure monitoring with Nexfin® does not sufficiently replace invasive measurements in critically ill patientsBritish Journal of Anaesthesia, 2013
- Development of a 64 channel ultrasonic high frequency linear array imaging systemUltrasonics, 2011
- Comparison of flow-mediated vasodilation in femoral and brachial arteries in healthy dogsAmerican Journal of Veterinary Research, 2011
- The Effect of Measuring Ambulatory Blood Pressure on Nighttime Sleep and Daytime Activity—Implications for DippingClinical Journal of the American Society of Nephrology, 2010
- Recommendations for Blood Pressure Measurement in Humans and Experimental AnimalsHypertension, 2005
- MASSAGE THERAPY OF MODERATE AND LIGHT PRESSURE AND VIBRATOR EFFECTS ON EEG AND HEART RATEInternational Journal of Neuroscience, 2004
- Remodeling of the Radial Artery in Response to a Chronic Increase in Shear StressHypertension, 1996
- Diameter and compliance in the human common carotid artery — variations with age and sexUltrasound in Medicine & Biology, 1995
- Local compression patterns beneath pneumatic tourniquets applied to arms and thighs of human cadaveraJournal of Orthopaedic Research, 1987
- Tissue hypoxia distal to a Peñaz finger blood pressure cuffJournal of Clinical Monitoring and Computing, 1985