Masaru Sugimachi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Masaru Sugimachi has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Shuji Shimizu
Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, Osaka, Japan
3 shared publications- Toru Kawada
National Cerebral and Cardiovascular Center
3 shared publications Aya Miyazaki
Department of Pediatric Cardiology, Congenital Heart Disease Center, Tenri Hospital, Nara, Japan
2 shared publicationsHeima Sakaguchi
Department of Pediatric Cardiology, National Cerebral and Cardiovascular Center, Osaka, Japan
2 shared publicationsHideo Ohuchi
Department of Pediatric Cardiology, National Cerebral and Cardiovascular Center, Osaka, Japan
2 shared publicationsJun Negishi
Department of Pediatric Cardiology, National Cerebral and Cardiovascular Center, Osaka, Japan
2 shared publications
Latest Publications
- Open Access
- 1 January 2020
- Published by Elsevier in The Journal of Physiological Sciences
- Vol. 70 (1) , 38-13
Impact of delayed ventricular wall area ratio on pathophysiology of mechanical dyssynchrony: implication from single-ventricle physiology and 0D modeling
- 1 January 2020
- Published by Elsevier in The Journal of Physiological Sciences
- Vol. 70 (1) , 38-13
Open AccessImpact of delayed ventricular wall area ratio on pathophysiology of mechanical dyssynchrony: implication from single-ventricle physiology and 0D modeling
- 23 March 2019
- Published by Springer Nature in Cardiovascular Drugs and Therapy
- Vol. 33 (3) , 277-286
AST-120, an Adsorbent of Uremic Toxins, Improves the Pathophysiology of Heart Failure in Conscious Dogs
Several lines of evidence suggest that renal dysfunction is associated with cardiovascular toxicity through the action of uremic toxins. The levels of those uremic toxins can be reportedly reduced by the spherical carbon adsorbent AST-120. Because heart failure (HF) causes renal dysfunction by low cardiac output and renal edema, the removal of uremic toxins could be cardioprotective.
- 23 March 2019
- Published by Springer Nature in Cardiovascular Drugs and Therapy
- Vol. 33 (3) , 277-286
AST-120, an Adsorbent of Uremic Toxins, Improves the Pathophysiology of Heart Failure in Conscious Dogs
Several lines of evidence suggest that renal dysfunction is associated with cardiovascular toxicity through the action of uremic toxins. The levels of those uremic toxins can be reportedly reduced by the spherical carbon adsorbent AST-120. Because heart failure (HF) causes renal dysfunction by low cardiac output and renal edema, the removal of uremic toxins could be cardioprotective.
- 15 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (4) , 934-945
A Novel Minimally Occlusive Cuff Method Utilizing Ultrasound Vascular Imaging for Stress-Free Blood Pressure Measurement: A-Proof-of-Concept Study
Objective: Occlusive cuff inflation in ambulatory blood pressure (BP) monitoring disturbs the daily life of the user, and affects efficacy of monitoring. To overcome this limitation, we have developed a novel minimally-occlusive cuff method for stress-free measurement of BP. This study aimed to experimentally evaluate the reliability of this method. Methods In this method, a thin-plate-type ultrasound probe placed between the cuff and the skin is used to measure the ultrasonic dimension of the artery. Analyzing the arterial dimension and the cuff pressure measured during mild cuff inflation (cuff pressure $\lt50$ mmHg) allows estimation of systolic ( $\rm SBP_e$ ) and diastolic BP ( $\rm DBP_e$ ). We evaluated this method in 6 anesthetized dogs by attaching the cuff with the probe to the right thigh to get $\rm SBP_e$ and $\rm DBP_e$ . We measured reference SBP and DBP using an intra-arterial catheter and determined the pulse arrival time (PAT) commonly employed in cuff-less BP monitoring. BP was perturbed by infusing noradrenaline or nitroprusside. Results: $\rm DBP_e$ correlated tightly with DBP with a coefficient of determination ( $\rm R^2$ ) of 0.85 ± 0.08, and predicted DBP with a bias of 3.9 ± 7.9 mmHg after a one-time calibration. Reciprocal of PAT correlated poorly with DBP ( $\rm R^2$ = 0.49 ± 0.17), and predicted DBP less accurately than this method. $\rm SBP_e$ correlated well with SBP ( $\rm R^2$ = 0.78 ± 0.08) Conclusion: This method reliably tracks BP changes without occlusive cuff inflation. Once calibrated, this method measures DBP accurately. Significance: This method has the potential for stress-free BP measurement in ambulatory BP monitoring.- 15 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (4) , 934-945
A Novel Minimally Occlusive Cuff Method Utilizing Ultrasound Vascular Imaging for Stress-Free Blood Pressure Measurement: A-Proof-of-Concept Study
Objective: Occlusive cuff inflation in ambulatory blood pressure (BP) monitoring disturbs the daily life of the user, and affects efficacy of monitoring. To overcome this limitation, we have developed a novel minimally-occlusive cuff method for stress-free measurement of BP. This study aimed to experimentally evaluate the reliability of this method. Methods In this method, a thin-plate-type ultrasound probe placed between the cuff and the skin is used to measure the ultrasonic dimension of the artery. Analyzing the arterial dimension and the cuff pressure measured during mild cuff inflation (cuff pressure $\lt50$ mmHg) allows estimation of systolic ( $\rm SBP_e$ ) and diastolic BP ( $\rm DBP_e$ ). We evaluated this method in 6 anesthetized dogs by attaching the cuff with the probe to the right thigh to get $\rm SBP_e$ and $\rm DBP_e$ . We measured reference SBP and DBP using an intra-arterial catheter and determined the pulse arrival time (PAT) commonly employed in cuff-less BP monitoring. BP was perturbed by infusing noradrenaline or nitroprusside. Results: $\rm DBP_e$ correlated tightly with DBP with a coefficient of determination ( $\rm R^2$ ) of 0.85 ± 0.08, and predicted DBP with a bias of 3.9 ± 7.9 mmHg after a one-time calibration. Reciprocal of PAT correlated poorly with DBP ( $\rm R^2$ = 0.49 ± 0.17), and predicted DBP less accurately than this method. $\rm SBP_e$ correlated well with SBP ( $\rm R^2$ = 0.78 ± 0.08) Conclusion: This method reliably tracks BP changes without occlusive cuff inflation. Once calibrated, this method measures DBP accurately. Significance: This method has the potential for stress-free BP measurement in ambulatory BP monitoring.- 15 April 2016
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 310 (8) , H973-H983
Development of a servo pump system for in vivo loading of pathological pulmonary artery impedance on the right ventricle of normal rats
Pulmonary artery (PA) impedance provides detailed information on right ventricular (RV) afterload in pulmonary hypertension (PH). This study aimed to examine PA impedance in a rat model of monocrotaline-induced PH (MCT-PH) and to develop an experimental system for in vivo loading of pathological PA impedance on the RV of normal rats. PA impedance was quantified in normal ( n = 10) and MCT-PH rats ( n = 10) using a three-element Windkessel (3-WK) model. Compared with normal rats, MCT-PH rats had higher characteristic impedance ( ZC) and peripheral pulmonary resistance ( RP) ( ZC: 0.121 ± 0.039 vs. 0.053 ± 0.017 mmHg·min·ml−1, P < 0.001; RP: 0.581 ± 0.334 vs. 0.252 ± 0.105 mmHg·min·ml−1, P = 0.013) and lower pulmonary artery compliance ( CP) (0.242 ± 0.131 vs. 0.700 ± 0.186 ml/mmHg, P < 0.001). In another group of 10 normal rats, a computer-controlled servo pump was connected to the left PA for loading PA impedance with parameters in pathological ranges designed by the 3-WK model. Activation of the servo pump decreased the error of measured vs. target PA impedance (modulus: from 0.047 ± 0.020 without pump activation to 0.019 ± 0.007 with pump activation, P < 0.001; phase: 0.085 ± 0.028 to 0.043 ± 0.012 radians, P < 0.001). In conclusion, MCT-PH increases ZCand RPand decreases CP. Our servo pump system, which is capable of imposing arbitrary PA impedance with pathological parameters, may offer a unique opportunity to delineate the pathological significance of PA impedance in PH.
- 15 April 2016
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 310 (8) , H973-H983
Development of a servo pump system for in vivo loading of pathological pulmonary artery impedance on the right ventricle of normal rats
Pulmonary artery (PA) impedance provides detailed information on right ventricular (RV) afterload in pulmonary hypertension (PH). This study aimed to examine PA impedance in a rat model of monocrotaline-induced PH (MCT-PH) and to develop an experimental system for in vivo loading of pathological PA impedance on the RV of normal rats. PA impedance was quantified in normal ( n = 10) and MCT-PH rats ( n = 10) using a three-element Windkessel (3-WK) model. Compared with normal rats, MCT-PH rats had higher characteristic impedance ( ZC) and peripheral pulmonary resistance ( RP) ( ZC: 0.121 ± 0.039 vs. 0.053 ± 0.017 mmHg·min·ml−1, P < 0.001; RP: 0.581 ± 0.334 vs. 0.252 ± 0.105 mmHg·min·ml−1, P = 0.013) and lower pulmonary artery compliance ( CP) (0.242 ± 0.131 vs. 0.700 ± 0.186 ml/mmHg, P < 0.001). In another group of 10 normal rats, a computer-controlled servo pump was connected to the left PA for loading PA impedance with parameters in pathological ranges designed by the 3-WK model. Activation of the servo pump decreased the error of measured vs. target PA impedance (modulus: from 0.047 ± 0.020 without pump activation to 0.019 ± 0.007 with pump activation, P < 0.001; phase: 0.085 ± 0.028 to 0.043 ± 0.012 radians, P < 0.001). In conclusion, MCT-PH increases ZCand RPand decreases CP. Our servo pump system, which is capable of imposing arbitrary PA impedance with pathological parameters, may offer a unique opportunity to delineate the pathological significance of PA impedance in PH.