In Vitro Effect of Lysozyme on Albumin Deposition to Hydrogel Contact Lens Materials
- 1 November 2017
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 94 (11) , 1047-1051
Abstract
SIGNIFICANCE: Albumin deposition on contact lenses could be detrimental to contact lens (CL) wear because this may increase the risk of bacterial binding and reduce comfort. Lysozyme deposition on selected lens materials would reduce albumin deposition on lenses. PURPOSE: This study aims to determine if lysozyme deposition on CLs could act as a barrier against subsequent albumin adsorption, using an in vitro model. METHODS: Six hydrogel CL materials (etafilcon A, polymacon, nelfilcon A, omafilcon A, ocufilcon B, and nesofilcon A) were evaluated. Four CLs of each type were soaked in lysozyme solution for 16 hours at 37°C. Lysozyme‐coated lenses were then placed in vials with 1.5 mL of artificial tear solution containing 125 I‐labeled albumin for 16 hours at 37°C with shaking. Four uncoated lenses of each type were used as controls. Lenses soaked in radiolabeled albumin were rinsed in a phosphate‐buffered saline solution, and radioactive counts were measured directly on lenses using a gamma counter. Albumin uptake on lenses was measured using a calibration curve by plotting radioactive counts versus protein concentration. RESULTS: Results are reported as mean ± SD. Lysozyme‐coated etafilcon A lenses exhibited lower levels of deposited albumin than uncoated etafilcon A lenses (58 ± 12 vs. 84 ± 5 ng/lens; P <. 05). There were no differences in albumin adsorption between control (uncoated) and lysozyme‐coated polymacon (105 ± 10 vs. 110 ± 34 ng/lens), nelfilcon A (51 ± 7 vs. 42 ± 20 ng/lens), omafilcon A (90 ± 20 vs. 80 ± 38 ng/lens), ocufilcon B (87 ± 20 vs. 115 ± 50 ng/lens), and nesofilcon A (170 ± 29 vs. 161 ± 10 ng/lens) lens materials ( P >. 05). Uncoated nesofilcon A lenses deposited the highest amount of albumin when compared with other uncoated lenses ( P <. 05). CONCLUSIONS: This study demonstrates that lysozyme deposited onto etafilcon A resists the deposition of albumin, which may potentially be beneficial to CL wearers.Keywords
This publication has 32 references indexed in Scilit:
- Influence of Protein Deposition on Bacterial Adhesion to Contact LensesOptometry and Vision Science, 2011
- Profile and Frequency of Microbial Contamination of Contact Lens CasesOptometry and Vision Science, 2010
- Care Regimen and Lens Material Influence on Silicone Hydrogel Contact Lens DepositionOptometry and Vision Science, 2009
- The Impact of Lipid on Contact Angle WettabilityOptometry and Vision Science, 2007
- Confocal Microscopy and Albumin Penetration into Contact LensesOptometry and Vision Science, 2007
- Kinetics ofIn VitroLysozyme Deposition on Silicone Hydrogel, PMMA, and FDA Groups I, II, and IV Contact Lens MaterialsCurrent Eye Research, 2006
- Quantitative and conformational characterization of lysozyme deposited on balafilcon and etafilcon contact lens materialsCurrent Eye Research, 2004
- Effect of hydrogel lens wear on the major tear proteins during extended wearAustralian and New Zealand Journal of Ophthalmology, 1997
- Adsorption and Removal of Protein Bound to Hydrogel Contact LensesOptometry and Vision Science, 1990
- Study of the Human Blood-Tear Barrier and the Biochemical Changes in the Tears of 30 Contact Lens Wearers (50 Eyes)Ophthalmologica, 1984