Negar Babaei Omali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Negar Babaei Omali has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Lyndon Jones
University of Waterloo
5 shared publications Zohra Fadli
Johnson and Johnson Vision Care, Inc. Jacksonville Florida
3 shared publicationsKristy Canavan
2 shared publicationsLakshman Subbaraman
2 shared publications- Miriam Heynen
Centre for Ocular Research & Education University of Waterloo Waterloo Ontario Canada
2 shared publications Chantal Bsc Coles-Brennan
Johnson and Johnson Vision Care, Inc. Jacksonville Florida
1 shared publication
Latest Publications
- 1 November 2017
- Published by Wiley in Optometry and Vision Science
- Vol. 94 (11) , 1047-1051
In Vitro Effect of Lysozyme on Albumin Deposition to Hydrogel Contact Lens Materials
SIGNIFICANCE: Albumin deposition on contact lenses could be detrimental to contact lens (CL) wear because this may increase the risk of bacterial binding and reduce comfort. Lysozyme deposition on selected lens materials would reduce albumin deposition on lenses. PURPOSE: This study aims to determine if lysozyme deposition on CLs could act as a barrier against subsequent albumin adsorption, using an in vitro model. METHODS: Six hydrogel CL materials (etafilcon A, polymacon, nelfilcon A, omafilcon A, ocufilcon B, and nesofilcon A) were evaluated. Four CLs of each type were soaked in lysozyme solution for 16 hours at 37°C. Lysozyme‐coated lenses were then placed in vials with 1.5 mL of artificial tear solution containing 125 I‐labeled albumin for 16 hours at 37°C with shaking. Four uncoated lenses of each type were used as controls. Lenses soaked in radiolabeled albumin were rinsed in a phosphate‐buffered saline solution, and radioactive counts were measured directly on lenses using a gamma counter. Albumin uptake on lenses was measured using a calibration curve by plotting radioactive counts versus protein concentration. RESULTS: Results are reported as mean ± SD. Lysozyme‐coated etafilcon A lenses exhibited lower levels of deposited albumin than uncoated etafilcon A lenses (58 ± 12 vs. 84 ± 5 ng/lens; P <. 05). There were no differences in albumin adsorption between control (uncoated) and lysozyme‐coated polymacon (105 ± 10 vs. 110 ± 34 ng/lens), nelfilcon A (51 ± 7 vs. 42 ± 20 ng/lens), omafilcon A (90 ± 20 vs. 80 ± 38 ng/lens), ocufilcon B (87 ± 20 vs. 115 ± 50 ng/lens), and nesofilcon A (170 ± 29 vs. 161 ± 10 ng/lens) lens materials ( P >. 05). Uncoated nesofilcon A lenses deposited the highest amount of albumin when compared with other uncoated lenses ( P <. 05). CONCLUSIONS: This study demonstrates that lysozyme deposited onto etafilcon A resists the deposition of albumin, which may potentially be beneficial to CL wearers.
- 1 November 2017
- Published by Wiley in Optometry and Vision Science
- Vol. 94 (11) , 1047-1051
In Vitro Effect of Lysozyme on Albumin Deposition to Hydrogel Contact Lens Materials
SIGNIFICANCE: Albumin deposition on contact lenses could be detrimental to contact lens (CL) wear because this may increase the risk of bacterial binding and reduce comfort. Lysozyme deposition on selected lens materials would reduce albumin deposition on lenses. PURPOSE: This study aims to determine if lysozyme deposition on CLs could act as a barrier against subsequent albumin adsorption, using an in vitro model. METHODS: Six hydrogel CL materials (etafilcon A, polymacon, nelfilcon A, omafilcon A, ocufilcon B, and nesofilcon A) were evaluated. Four CLs of each type were soaked in lysozyme solution for 16 hours at 37°C. Lysozyme‐coated lenses were then placed in vials with 1.5 mL of artificial tear solution containing 125 I‐labeled albumin for 16 hours at 37°C with shaking. Four uncoated lenses of each type were used as controls. Lenses soaked in radiolabeled albumin were rinsed in a phosphate‐buffered saline solution, and radioactive counts were measured directly on lenses using a gamma counter. Albumin uptake on lenses was measured using a calibration curve by plotting radioactive counts versus protein concentration. RESULTS: Results are reported as mean ± SD. Lysozyme‐coated etafilcon A lenses exhibited lower levels of deposited albumin than uncoated etafilcon A lenses (58 ± 12 vs. 84 ± 5 ng/lens; P <. 05). There were no differences in albumin adsorption between control (uncoated) and lysozyme‐coated polymacon (105 ± 10 vs. 110 ± 34 ng/lens), nelfilcon A (51 ± 7 vs. 42 ± 20 ng/lens), omafilcon A (90 ± 20 vs. 80 ± 38 ng/lens), ocufilcon B (87 ± 20 vs. 115 ± 50 ng/lens), and nesofilcon A (170 ± 29 vs. 161 ± 10 ng/lens) lens materials ( P >. 05). Uncoated nesofilcon A lenses deposited the highest amount of albumin when compared with other uncoated lenses ( P <. 05). CONCLUSIONS: This study demonstrates that lysozyme deposited onto etafilcon A resists the deposition of albumin, which may potentially be beneficial to CL wearers.
- 8 June 2017
- Published by Taylor & Francis in Journal of Biomaterials Science, Polymer Edition
- Vol. 28 (13) , 1351-1364
Selectivity and localization of lysozyme uptake in contemporary hydrogel contact lens materials
The purpose of this study was to investigate the early and selective uptake of lysozyme and the location of deposited lysozyme on contemporary hydrogel contact lens (CL) materials after exposure to an artificial tear solution (ATS) for 16 h. Seven different hydrogel CL materials [polymacon, omafilcon A, nelfilcon A, nesofilcon A, ocufilcon B, etafilcon A (Acuvue Moist), and etafilcon A (Acuvue Define)] were incubated in an ATS for various times. Total protein deposition was determined using a modified Bradford technique. Lysozyme, lactoferrin, and albumin deposition on CLs were determined using 125I-radiolabeling method. A confocal laser scanning microscopy (CLSM) technique was utilized to map the location of lysozyme uptake in an asymmetric environment. All lens materials had significant amounts of lysozyme after 1 min of exposure to ATS. After 16 h of incubation, higher levels of total protein deposited on the two etafilcon A-based lenses (Moist and Define), followed by ocufilcon B and both were significantly higher than all other CLs tested (p = 0.0001). The two etafilcon A materials (Moist and Define) also deposited the highest amounts of lysozyme (514.8 ± 28.4 and 527.1 ± 14.7 μg/lens respectively) when compared to other test CLs (p = 0.0001). The CLSM technique revealed that the non-ionic CLs tended to have symmetric distribution of lysozyme throughout the lens materials, while the ionic CLs had an asymmetric distribution, with the highest concentration of lysozyme on and near the exposed surface. The quantity and nature of proteins deposited on CLs varies, depending upon the chemical composition of the material. Among the various lenses tested, etafilcon A deposited the highest amount of total protein, most of it represented by lysozyme, which was largely located near the surface of the lens.
- 8 June 2017
- Published by Taylor & Francis in Journal of Biomaterials Science, Polymer Edition
- Vol. 28 (13) , 1351-1364
Selectivity and localization of lysozyme uptake in contemporary hydrogel contact lens materials
The purpose of this study was to investigate the early and selective uptake of lysozyme and the location of deposited lysozyme on contemporary hydrogel contact lens (CL) materials after exposure to an artificial tear solution (ATS) for 16 h. Seven different hydrogel CL materials [polymacon, omafilcon A, nelfilcon A, nesofilcon A, ocufilcon B, etafilcon A (Acuvue Moist), and etafilcon A (Acuvue Define)] were incubated in an ATS for various times. Total protein deposition was determined using a modified Bradford technique. Lysozyme, lactoferrin, and albumin deposition on CLs were determined using 125I-radiolabeling method. A confocal laser scanning microscopy (CLSM) technique was utilized to map the location of lysozyme uptake in an asymmetric environment. All lens materials had significant amounts of lysozyme after 1 min of exposure to ATS. After 16 h of incubation, higher levels of total protein deposited on the two etafilcon A-based lenses (Moist and Define), followed by ocufilcon B and both were significantly higher than all other CLs tested (p = 0.0001). The two etafilcon A materials (Moist and Define) also deposited the highest amounts of lysozyme (514.8 ± 28.4 and 527.1 ± 14.7 μg/lens respectively) when compared to other test CLs (p = 0.0001). The CLSM technique revealed that the non-ionic CLs tended to have symmetric distribution of lysozyme throughout the lens materials, while the ionic CLs had an asymmetric distribution, with the highest concentration of lysozyme on and near the exposed surface. The quantity and nature of proteins deposited on CLs varies, depending upon the chemical composition of the material. Among the various lenses tested, etafilcon A deposited the highest amount of total protein, most of it represented by lysozyme, which was largely located near the surface of the lens.
- Open Access
- 1 July 2015
- Published by Wiley in Optometry and Vision Science
- Vol. 92 (7) , 750-757
Biological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses
Within a few minutes of wear, contact lenses become rapidly coated with a variety of tear film components, including proteins, lipids, and mucins. Tears have a rich and complex composition, allowing a wide range of interactions and competitive processes, with the first event observed at the interface between a contact lens and tear fluid being protein adsorption. Protein adsorption on hydrogel contact lenses is a complex process involving a variety of factors relating to both the protein in question and the lens material. Among tear proteins, lysozyme is a major protein that has both antibacterial and anti‐inflammatory functions. Contact lens materials that have high ionicity and high water content have an increased affinity to accumulate lysozyme during wear, when compared with other soft lens materials, notably silicone hydrogel lenses. This review provides an overview of tear film proteins, with a specific focus on lysozyme, and examines various factors that influence protein deposition on contact lenses. In addition, the impact of lysozyme deposition on various ocular physiological responses and bacterial adhesion to lenses and the interaction of lysozyme with other tear proteins are reviewed. This comprehensive review suggests that deposition of lysozyme on contact lens materials may provide a number of beneficial effects during contact lens wear.
- 1 July 2015
- Published by Wiley in Optometry and Vision Science
- Vol. 92 (7) , 750-757
Open AccessBiological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses
Within a few minutes of wear, contact lenses become rapidly coated with a variety of tear film components, including proteins, lipids, and mucins. Tears have a rich and complex composition, allowing a wide range of interactions and competitive processes, with the first event observed at the interface between a contact lens and tear fluid being protein adsorption. Protein adsorption on hydrogel contact lenses is a complex process involving a variety of factors relating to both the protein in question and the lens material. Among tear proteins, lysozyme is a major protein that has both antibacterial and anti‐inflammatory functions. Contact lens materials that have high ionicity and high water content have an increased affinity to accumulate lysozyme during wear, when compared with other soft lens materials, notably silicone hydrogel lenses. This review provides an overview of tear film proteins, with a specific focus on lysozyme, and examines various factors that influence protein deposition on contact lenses. In addition, the impact of lysozyme deposition on various ocular physiological responses and bacterial adhesion to lenses and the interaction of lysozyme with other tear proteins are reviewed. This comprehensive review suggests that deposition of lysozyme on contact lens materials may provide a number of beneficial effects during contact lens wear.
- 1 February 2015
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 38, e37
Is there a difference between clinical signs and symptoms in asymptomatic adapted contact lens and spectacle wearers?
- 1 February 2015
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 38, e37
Is there a difference between clinical signs and symptoms in asymptomatic adapted contact lens and spectacle wearers?
- 1 February 2015
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 38, e33
Is there a difference in tear film and meibum composition in asymptomatic adapted contact lens and spectacle wearers?
- 1 February 2015
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 38, e33
Is there a difference in tear film and meibum composition in asymptomatic adapted contact lens and spectacle wearers?