Efficacy and Safety of High‐Power Short‐Duration Ablation for Cavo‐Tricuspid Isthmus With a Flexible‐Tip Temperature‐Controlled Power Regulation Catheter Performed by Electrophysiology Trainees
- 11 December 2024
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (2) , 367-375
Abstract
Introduction: The suitability of high‐power short‐duration (HPSD) cavo‐tricuspid isthmus ablation (CTI‐Abl) for electrophysiology (EP) trainees, as well as the underlying mechanisms of its efficacy, remain unknown. The aim of this study was to clarify the efficacy and safety of HPSD CTI‐Abl performed by EP trainees and assess lesion characteristics between HPSD and moderate‐power long duration (MPLD) ablations.Methods: Study 1: CTI‐Abl was performed by first‐ to fourth‐year EP trainees in consecutive 113 patients (67 ± 11 years, 27.2% female). Study cohort was historically divided into three groups: MPLD (30–35 W for up to 30 s) using TactiCath (TC‐MPLD, N = 38) and MPLD and HPSD (50 W for 12 s) using TactiFlex (TF‐MPLD, N = 23; TF‐HPSD, N = 52). Primary endpoint was first‐pass bidirectional isthmus block (BIB). Study 2: lesion geometries created by each ablation strategy were compared using an ex‐vivo model.Results: Study 1: TF‐HPSD ablation strategy demonstrated a higher success rate of first‐pass BIB than MPLD protocol (TC‐MPLD, 58%; TF‐MPLD, 48%; TF‐HPSD, 94%, p < 0.001), without any complications. TF‐HPSD group was associated with shorter total procedure and RF application times, as well as fewer ablation points and gaps, compared to the MPLD groups. Study 2: TF‐HPSD created greater lesion surface length, width, and area than MPLD strategies.Conclusion: HPSD CTI‐Abl performed by EP trainees using TactiFlex SE catheter demonstrated a higher first‐pass BIB rate, shorter total procedure and RF application times, and fewer ablation points and gaps compared to the conventional method, without increasing complication rates.Keywords
This publication has 30 references indexed in Scilit:
- An optimized approach for increasing lesion size in temperature‐controled setting using a catheter with a surface thermocouple and efficient irrigationJournal of Arrhythmia, 2024
- 2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillationHeart Rhythm, 2024
- Efficacy and safety of high-power short-duration ablation for atrial fibrillation: a systematic review and meta-analysis of randomized controlled trialsJournal of Interventional Cardiac Electrophysiology, 2024
- Safe and effective delivery of high-power, short-duration radiofrequency ablation lesions with a flexible-tip ablation catheterHeart Rhythm O2, 2022
- Impact of a formula combining local impedance and conventional parameters on lesion size predictionJournal of Interventional Cardiac Electrophysiology, 2021
- Clinical implications of local impedance measurement using the IntellaNav MiFi OI ablation catheter: an ex vivo studyJournal of Interventional Cardiac Electrophysiology, 2021
- High-power short-duration radiofrequency ablation of typical atrial flutterHeart Rhythm O2, 2020
- A comparison of 8‐mm and open‐irrigated gold‐tip catheters for typical atrial flutter ablation: Data from a prospective multicenter registryJournal of Arrhythmia, 2018
- Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmiasHeart Rhythm, 2012
- Clinical Study Regarding the Anatomical Structures of the Right Atrial Isthmus Using Intra-Cardiac Echocardiography: Implication for Catheter Ablation of Common Atrial FlutterJournal of Interventional Cardiac Electrophysiology, 2005