A 760 mV PP -Input-Range, 103.6dB-SNDR Direct-Digitization Sensor Readout With Pseudo-Differential Integrator and Impedance-Equalized RDAC
- 1 May 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. PP (00189200) , 1-13
Abstract
A high-precision, direct-digitization sensor readout (DD-RO) based on a continuous-time delta-sigma modulator (CT- $\Delta \Sigma $ M) is presented. The proposed DD-RO incorporates several key innovations to enhance performance. First, a pseudo-differential current-balancing integrator (PD-CBI) significantly extends the linear input range, whereas its intrinsically limited common-mode input range and CMRR are both improved by a common-mode cancellation loop (CMCL). Second, the PD-CBI enables quasi-quiet chopping for 1/ $f$ noise suppression and provides high input impedance. A multibit resistive DAC (RDAC) further increases the input impedance by reducing the transconductor’s net input voltage. Finally, an impedance-equalization technique employing auxiliary RDACs alleviates the signal-dependent nonlinearity arising from reference-path parasitics and DAC current variation. Fabricated in a 0.18- $\mu $ m CMOS process, the prototype achieves an input-referred noise (IRN) of 66nV/ $\surd $ Hz, a 760mVPP linear input range at 1.2V supply, and a calibration-free input impedance of 7.83 G $\Omega $ and a CMRR of 82dB, both measured at 50Hz. The DD-RO achieves a peak SNDR of 103.6dB and a dynamic range (DR) of 105dB, corresponding to state-of-the-art figures of merit of FoM ${}_{\mathrm {SNDR}}= 173.5$ dB and FoM ${}_{\mathrm {DR}} = 174.9$ dB, respectively.Keywords
Funding Information
- National Natural Science Foundation of China (62474046)
This publication has 42 references indexed in Scilit:
- Near-zero nonlinear error pressure sensor based on piezoresistor sensitivity matching for wind tunnel pressure testMicrosystems & Nanoengineering, 2025
- 3D printable and myoelectrically sensitive hydrogel for smart prosthetic hand controlMicrosystems & Nanoengineering, 2025
- Fabric-based lamina emergent MXene-based electrode for electrophysiological monitoringNature Communications, 2024
- A 103.6dB-SNDR 760mVPP-Input-Range 7.8GΩ-Input-Impedance Direct-Digitization Sensor Readout with Pseudo-Differential Transconductors and Dummy DAC2024
- Iontronic pressure sensor with high sensitivity over ultra-broad linear range enabled by laser-induced gradient micro-pyramidsNature Communications, 2023
- A 15.5b-ENOB 335mVpp-Linear-Input-Range 4.7GΩ-Input-Impedance Direct-ADC Based Analog Front-End2023
- Optimal design of dual air-gap closed-loop TMR current sensor based on minimum magnetic field uniformity coefficientScientific Reports, 2023
- Towards gel-free electrodes: A systematic study of electrode-skin impedanceSensors and Actuators B: Chemical, 2017
- A continuous-time ΣΔ modulator with a Gm-C input stage, 120-dB CMRR and −87 dB THD2011
- Electric current sensors: a reviewMeasurement Science and Technology, 2010