Yuying Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuying Li has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jiawei Xu
Fudan University
4 shared publications - Zhiliang Hong
Fudan University
4 shared publications - Tianxiang Qu
State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China
3 shared publications - Hao Li
State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China
2 shared publications Jianhong Zhou
State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China
2 shared publications- Liheng Liu
State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China
2 shared publications
Latest Publications
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. PP (00189200) , 1-13
A 760 mV PP -Input-Range, 103.6dB-SNDR Direct-Digitization Sensor Readout With Pseudo-Differential Integrator and Impedance-Equalized RDAC
A high-precision, direct-digitization sensor readout (DD-RO) based on a continuous-time delta-sigma modulator (CT- $\Delta \Sigma $ M) is presented. The proposed DD-RO incorporates several key innovations to enhance performance. First, a pseudo-differential current-balancing integrator (PD-CBI) significantly extends the linear input range, whereas its intrinsically limited common-mode input range and CMRR are both improved by a common-mode cancellation loop (CMCL). Second, the PD-CBI enables quasi-quiet chopping for 1/ $f$ noise suppression and provides high input impedance. A multibit resistive DAC (RDAC) further increases the input impedance by reducing the transconductor’s net input voltage. Finally, an impedance-equalization technique employing auxiliary RDACs alleviates the signal-dependent nonlinearity arising from reference-path parasitics and DAC current variation. Fabricated in a 0.18- $\mu $ m CMOS process, the prototype achieves an input-referred noise (IRN) of 66nV/ $\surd $ Hz, a 760mVPP linear input range at 1.2V supply, and a calibration-free input impedance of 7.83 G $\Omega $ and a CMRR of 82dB, both measured at 50Hz. The DD-RO achieves a peak SNDR of 103.6dB and a dynamic range (DR) of 105dB, corresponding to state-of-the-art figures of merit of FoM ${}_{\mathrm {SNDR}}= 173.5$ dB and FoM ${}_{\mathrm {DR}} = 174.9$ dB, respectively.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. PP (00189200) , 1-13
A 760 mV PP -Input-Range, 103.6dB-SNDR Direct-Digitization Sensor Readout With Pseudo-Differential Integrator and Impedance-Equalized RDAC
A high-precision, direct-digitization sensor readout (DD-RO) based on a continuous-time delta-sigma modulator (CT- $\Delta \Sigma $ M) is presented. The proposed DD-RO incorporates several key innovations to enhance performance. First, a pseudo-differential current-balancing integrator (PD-CBI) significantly extends the linear input range, whereas its intrinsically limited common-mode input range and CMRR are both improved by a common-mode cancellation loop (CMCL). Second, the PD-CBI enables quasi-quiet chopping for 1/ $f$ noise suppression and provides high input impedance. A multibit resistive DAC (RDAC) further increases the input impedance by reducing the transconductor’s net input voltage. Finally, an impedance-equalization technique employing auxiliary RDACs alleviates the signal-dependent nonlinearity arising from reference-path parasitics and DAC current variation. Fabricated in a 0.18- $\mu $ m CMOS process, the prototype achieves an input-referred noise (IRN) of 66nV/ $\surd $ Hz, a 760mVPP linear input range at 1.2V supply, and a calibration-free input impedance of 7.83 G $\Omega $ and a CMRR of 82dB, both measured at 50Hz. The DD-RO achieves a peak SNDR of 103.6dB and a dynamic range (DR) of 105dB, corresponding to state-of-the-art figures of merit of FoM ${}_{\mathrm {SNDR}}= 173.5$ dB and FoM ${}_{\mathrm {DR}} = 174.9$ dB, respectively.
- Open Access
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Solid-State Circuits Society
- Vol. 5, 251-268
Analog Front-End Circuit Techniques for Wearable ExG, BioZ, and PPG Signal Acquisition: A Review
Wearable platforms that concurrently acquire multiple physiological signals enable comprehensive health monitoring but impose stringent requirements on front-end circuit design. The reliable extraction of low-amplitude and low-frequency biosignals is hindered by electrode offset, noise, motion artifacts, and environmental interference. Recent efforts have advanced analog front ends (AFEs) for biopotential (ExG), bioimpedance (BioZ), and photoplethysmography (PPG) sensing, with emphasis on optimizing key metrics such as noise efficiency, input impedance, dynamic range, CMRR, and power consumption. In addition, digitally assisted calibration and direct-digitization schemes have emerged as alternative design directions, offering enhanced robustness and scalability while introducing trade-offs in complexity and energy efficiency. This review surveys these circuit techniques, analyzes their design trade-offs, and outlines future opportunities for next-generation wearable biomedical interfaces.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Solid-State Circuits Society
- Vol. 5, 251-268
Open AccessAnalog Front-End Circuit Techniques for Wearable ExG, BioZ, and PPG Signal Acquisition: A Review
Wearable platforms that concurrently acquire multiple physiological signals enable comprehensive health monitoring but impose stringent requirements on front-end circuit design. The reliable extraction of low-amplitude and low-frequency biosignals is hindered by electrode offset, noise, motion artifacts, and environmental interference. Recent efforts have advanced analog front ends (AFEs) for biopotential (ExG), bioimpedance (BioZ), and photoplethysmography (PPG) sensing, with emphasis on optimizing key metrics such as noise efficiency, input impedance, dynamic range, CMRR, and power consumption. In addition, digitally assisted calibration and direct-digitization schemes have emerged as alternative design directions, offering enhanced robustness and scalability while introducing trade-offs in complexity and energy efficiency. This review surveys these circuit techniques, analyzes their design trade-offs, and outlines future opportunities for next-generation wearable biomedical interfaces.
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (6) , 1132-1141
A 101-dB DR 2.2GΩ-Input-Impedance Direct Digitization ExG Front-End With Δ-Modulation
Long-term, continuous health monitoring imposes stringent demands on bio-recording analog front-end (AFE) circuits, specifically in terms of dynamic range (DR), noise, input impedance, and power consumption. This work introduces a DR-enhanced direct-digitization AFE based on a Δ-modulated transconductor (TC) stage, followed by a second-order ΔΣ ADC. In this architecture, the accumulated DAC is subtracted exclusively at the TC input stage, allowing the integrators to process only the low-amplitude Δ-modulated signal and thus relaxing the dynamic range constraints of conventional Gm-C ΔΣ ADCs. The TC input stage achieves high input impedance and high linearity through a current-balancing transconductor and a flipped-voltage-follower (FVF) loop. Fabricated with a standard 180nm CMOS process, the proposed Δ-ΔΣ AFE exhibits an SNDR of 91 dB, a dynamic range of 101 dB, input referred noise of 58 nV/√Hz, and a power consumption of 63 μW. These results correspond to a FoMSNDR of 160.1 dB and a FoMDR of 170 dB. The AFE prototype has been validated through scalp EEG, leg EMG, and chest ECG with significant body movements, demonstrating its effectiveness as a motion-artifact-tolerant direct-ADC front end.
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (6) , 1132-1141
A 101-dB DR 2.2GΩ-Input-Impedance Direct Digitization ExG Front-End With Δ-Modulation
Long-term, continuous health monitoring imposes stringent demands on bio-recording analog front-end (AFE) circuits, specifically in terms of dynamic range (DR), noise, input impedance, and power consumption. This work introduces a DR-enhanced direct-digitization AFE based on a Δ-modulated transconductor (TC) stage, followed by a second-order ΔΣ ADC. In this architecture, the accumulated DAC is subtracted exclusively at the TC input stage, allowing the integrators to process only the low-amplitude Δ-modulated signal and thus relaxing the dynamic range constraints of conventional Gm-C ΔΣ ADCs. The TC input stage achieves high input impedance and high linearity through a current-balancing transconductor and a flipped-voltage-follower (FVF) loop. Fabricated with a standard 180nm CMOS process, the proposed Δ-ΔΣ AFE exhibits an SNDR of 91 dB, a dynamic range of 101 dB, input referred noise of 58 nV/√Hz, and a power consumption of 63 μW. These results correspond to a FoMSNDR of 160.1 dB and a FoMDR of 170 dB. The AFE prototype has been validated through scalp EEG, leg EMG, and chest ECG with significant body movements, demonstrating its effectiveness as a motion-artifact-tolerant direct-ADC front end.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
An IoT-Enabled Wearable Health Monitor for Synchronized ExG, PPG, and BioZ Measurement
The multimodal wearable health monitor is designed for patients with chronic conditions and leverage edge data pre-processing for efficiency. It supports a variety of use cases: a brain monitoring headband for measuring electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS), a chest health patch for sensing electrocardiography (ECG), RR intervals (RRI), bioimpedance (BioZ), and photoplethysmography (PPG), and a fitness legband for recording electromyograph (EMG) and PPG. Similar devices can also be connected to a Body Sensor Network for comprehensive health monitoring. The system includes a flexible PPG sensor and a data acquisition (DAQ) board with integrated bioimpedance and biopotential channels. They feature a low input-referred noise level of 25 pArms (BW=10 Hz), 6.06 Ωrms (BW=0.05-4 Hz), and 0.77 μVrms (BW=0.05-150 Hz), respectively. The multimodal health monitor consumes 30.4 mW of power and can operate continuously for 36 hours. The flexible sensor, with a 1 cm diameter and a bending radius of 66.6 μm, conforms to the skin for versatile detection. Edge data pre-processing and offloading tasks to the PC helps reduce data redundancy and latency. The overall platform enables remote real-time monitoring, historical data queries, and email alerts. The results indicate that the average correlation of EEG signals was 96.21% in the eyes-open and eyes-closed tests, and the alpha rhythm was clear. During the breath-holding test, the SpO2 level changed by 10%. In chest synchronization, the heart rate increased by 2 bpm every 3 seconds. The Mean Absolute Error (MAE) of the heart rate test for five subjects was 1.38%, and the Mean Absolute Percentage Error (MAPE) was 1.98%.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
An IoT-Enabled Wearable Health Monitor for Synchronized ExG, PPG, and BioZ Measurement
The multimodal wearable health monitor is designed for patients with chronic conditions and leverage edge data pre-processing for efficiency. It supports a variety of use cases: a brain monitoring headband for measuring electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS), a chest health patch for sensing electrocardiography (ECG), RR intervals (RRI), bioimpedance (BioZ), and photoplethysmography (PPG), and a fitness legband for recording electromyograph (EMG) and PPG. Similar devices can also be connected to a Body Sensor Network for comprehensive health monitoring. The system includes a flexible PPG sensor and a data acquisition (DAQ) board with integrated bioimpedance and biopotential channels. They feature a low input-referred noise level of 25 pArms (BW=10 Hz), 6.06 Ωrms (BW=0.05-4 Hz), and 0.77 μVrms (BW=0.05-150 Hz), respectively. The multimodal health monitor consumes 30.4 mW of power and can operate continuously for 36 hours. The flexible sensor, with a 1 cm diameter and a bending radius of 66.6 μm, conforms to the skin for versatile detection. Edge data pre-processing and offloading tasks to the PC helps reduce data redundancy and latency. The overall platform enables remote real-time monitoring, historical data queries, and email alerts. The results indicate that the average correlation of EEG signals was 96.21% in the eyes-open and eyes-closed tests, and the alpha rhythm was clear. During the breath-holding test, the SpO2 level changed by 10%. In chest synchronization, the heart rate increased by 2 bpm every 3 seconds. The Mean Absolute Error (MAE) of the heart rate test for five subjects was 1.38%, and the Mean Absolute Percentage Error (MAPE) was 1.98%.