Method of test and survey of caprolactam migration into foods packaged in nylon-6
Authors:
- E. L. BradleyEBE. L. Bradley
- D. R. SpeckDSD. R. Speck
- W. A. ReadWRW. A. Read
- L. CastleLCL. Castle
- 1 December 2004
- journal article
- research article
- Published by Taylor & Francis in Food Additives & Contaminants
- Vol. 21 (12) , 1179-1185
Abstract
An analytical method for the determination of the nylon-6 monomer caprolactam in foods is described. The foodstuff was extracted with ethanol : water (1:2) containing capryllactam as internal standard and the extract was defatted using hexane. The extract was analysed by liquid chromatography coupled with mass spectrometry. The test method was calibrated down to 0.7 mg kg−1. The repeatability of the method was good, with a relative standard deviation of 9% at the 15 mg kg−1 level. The method was demonstrated to be accurate in an independent external check sample exercise. The new method was applied to the analysis of 50 retail foodstuffs packaged in nylon-6. Caprolactam was detected and confirmed in nine of the 50 food samples, in the range 2.8–13 mg kg−1. The presence of caprolactam was indicated in a further 15 samples, in the range 0.8–11 mg kg−1, but these samples did not meet all of the five confirmation criteria applied. All migration levels (both confirmed and unconfirmed) were below the European specific migration limit for caprolactam, which is 15 mg kg−1. The average migration for all 50 samples, setting non-detectables at half the limit of detection, was 2.6 mg kg−1 with a standard deviation of 3.1 mg kg−1 (n = 50). All samples found to contain detectable levels of caprolactam migration were for applications involving heating the food in the packaging. They were packs of, for example, sausage meat for which the food would have been heat processed in the nylon casing, or they were nylon pouches for heating foods by boiling, microwaving or roasting.Keywords
This publication has 7 references indexed in Scilit:
- Determination of ϵ‐caprolactam migration from polyamide plastics: a new approachPackaging Technology and Science, 2001
- Gas chromatographic determination of e-caprolactam migrated from plastic articlesPolimery, 1999
- Migration from polyamide ‘microwave and roasting bags’ into roast chickenFood Additives & Contaminants, 1998
- Determination of potential migrants present in Nylon ‘microwave and roasting bags’ and migration into olive oilFood Additives & Contaminants, 1997
- Determination of migrants in and migration from nylon food packagingFood Additives & Contaminants, 1995
- Analysis of migrants from nylon 6 packaging films into boiling waterFood Additives & Contaminants, 1993
- Evaluation of analytical methods used for regulation of foods and drugsAnalytical Chemistry, 1982