EBE. L. Bradley

E. L. Bradley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


E. L. Bradley has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Identification of Potential Migrants in Epoxy Phenolic Can Coatings

    by E. L. Bradley, M. Driffield, N. Harmer, P. K. T. Oldring, L. Castle

    A test protocol has been developed that contains a suite of complementary analytical methods to identify and estimate the concentrations of potential chemical migrants in polymeric coatings applied to metal substrates. The capabilities of these techniques (FT-IR, overall migration, headspace GC-MS, GC-MS, and LC-TOF-MS) have been tested for a variety of polymeric coatings, and the results for one particular coating, an epoxy phenolic, are described as an example. The example provided shows both the power and the limitations of current analytical techniques in the evaluation of the total migrate from food contact materials.


  • Investigation into the migration potential of coating materials from cookware products

    by E. L. Bradley, W. A. Read, L. Castle

    Twenty-six non-stick-coated cookware samples were purchased, covering a variety of products, coating/metal types and food contact applications. The polymer coatings were identified to be polyethersulphone, polytetrafluoroethylene (PTFE), bisphenol A/epichlorohydrin and one coating for which no good match was obtained with infra-red library spectra. All of the products intended for stove-top use had a polymer coating containing PTFE. The coatings were analysed as purchased and after heating at 250°C for 30 min to simulate actual conditions of use. Total solvent extractables were measured and the overall migration was determined into simulants. None of the products exceeded an overall migration limit of 10 mg dm−2. Coating materials were analysed by headspace gas chromatography–mass spectrometry (GC–MS), by liquid extraction followed by GC–MS and by liquid extraction followed by liquid chromatography–mass spectroscopy with a particle-beam interface. Benzene was detected in two samples, at 1.4 and 2.4 µg dm−2. These levels in the coatings are too low to give any detectable migration into foods. There was no detectable release of perfluorochemicals. Several other substances were identified and the worst-case migration was calculated. The origin of many of the substances detected was considered to be by pick-up from the printed packaging materials in which the cookware was sold. Potential consumer exposure was calculated. None of the substances identified had the potential to exceed their tolerable daily intake (TDI) value. To confirm these worst-case calculations, the migration of certain phthalates and of bisphenol A was measured into food simulants. Migration levels were very low.


  • Survey of the migration of melamine and formaldehyde from melamine food contact articles available on the UK market

    by E. L Bradley, V Boughtflower, T. L Smith, D. R Speck, L Castle

    The migration of melamine and formaldehyde, monomers used in the production of melamine-ware food contact articles, has been determined from 50 retail articles purchased in the UK. The food simulant 3% aqueous acetic acid was used as this is the most aggressive simulant towards melamine plastics. The test conditions used were repeated exposure to the simulant for 2 hours at 70°C, since the articles were all intended for general use including contact with hot foods and beverages. Melamine migrated from 43 of the 50 samples tested and formaldehyde migrated from all 50 samples. Directive 2002/72/EC specifies migration limits for both of these monomers in foods and food simulants. Melamine is restricted by a specific migration limit (SML) of 30 mg/kg (equivalent to 5 mg/dm2) and formaldehyde, along with hexamethylenetetramine expressed as formaldehyde, is restricted by a total (T) SML(T) of 15 mg/kg (equivalent to 2.5 mg/dm2). In all cases the migration of melamine was much lower than the SML for this monomer. The migration of formaldehyde exceeded the SML(T) for 5 of the 50 samples tested. The failure to comply with the SML(T) was accompanied by a number of visible surface effects including discolouration and/or pitting of the simulant contact surface and cracking of the articles. Similar surface effects were observed when one of the samples was exposed to fruit juice which confirmed the suitability of the exposure conditions and 3% acetic acid as a simulant for the articles tested. The ratio of specific migration to overall migration was consistent with, but did not prove, the hypothesis that high formaldehyde migration could be due to the use of excessive hexamethylenetetramine in the polymer formulation. All illegal products were voluntarily removed from the market by the product suppliers.


  • Method of test and survey of caprolactam migration into foods packaged in nylon-6

    by E. L. Bradley, D. R. Speck, W. A. Read, L. Castle

    An analytical method for the determination of the nylon-6 monomer caprolactam in foods is described. The foodstuff was extracted with ethanol : water (1:2) containing capryllactam as internal standard and the extract was defatted using hexane. The extract was analysed by liquid chromatography coupled with mass spectrometry. The test method was calibrated down to 0.7 mg kg−1. The repeatability of the method was good, with a relative standard deviation of 9% at the 15 mg kg−1 level. The method was demonstrated to be accurate in an independent external check sample exercise. The new method was applied to the analysis of 50 retail foodstuffs packaged in nylon-6. Caprolactam was detected and confirmed in nine of the 50 food samples, in the range 2.8–13 mg kg−1. The presence of caprolactam was indicated in a further 15 samples, in the range 0.8–11 mg kg−1, but these samples did not meet all of the five confirmation criteria applied. All migration levels (both confirmed and unconfirmed) were below the European specific migration limit for caprolactam, which is 15 mg kg−1. The average migration for all 50 samples, setting non-detectables at half the limit of detection, was 2.6 mg kg−1 with a standard deviation of 3.1 mg kg−1 (n = 50). All samples found to contain detectable levels of caprolactam migration were for applications involving heating the food in the packaging. They were packs of, for example, sausage meat for which the food would have been heat processed in the nylon casing, or they were nylon pouches for heating foods by boiling, microwaving or roasting.