A Radiate Microstructure MALDI Chip for Sample Concentration and Detection
Authors:
- 16 June 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (14) , 5951-5957
Abstract
Although matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) analysis is an important tool for analyzing and characterizing biomolecules of varying complexity, the sensitivity of MALDI-TOFMS is dependent on proper preparation of the sample, a process that is oftentimes problematic and requires considerable expertise. In this study, we have developed a radiate microstructure chip on which samples can be concentrated for analysis by MALDI-TOFMS. The sample/matrix mixture was deposited onto the central space of the well on the chip and allowed to dry. Microscopic analysis confirmed that the applied samples were confined to the central zone. Sample spots focused on the chip were much smaller than those on an unmodified plate with the same total volume. Optimizing processes of several preparation factors were also performed to ensure matrix homogeneity in our chip. Analysis of the samples with MALDI-TOFMS showed that the signals from samples on our chip were significantly greater than those on the unmodified plate. The feasibility of using this chip to detect peptides and phosphopeptides was also demonstrated.Keywords
This publication has 16 references indexed in Scilit:
- Phosphopeptide Enrichment Using MALDI Plates Modified with High-Capacity Polymer BrushesAnalytical Chemistry, 2008
- Self‐assembled‐monolayer‐modified silicon substrate to enhance the sensitivity of peptide detection for AP‐MALDI mass spectrometryJournal of Mass Spectrometry, 2007
- Dissipation of charge on MALDI‐TOF polymeric chips using an electron‐acceptor: analysis of proteinsJournal of Mass Spectrometry, 2007
- Recent developments in methods and technology for analysis of biological samples by MALDI-TOF-MSAnalytical and Bioanalytical Chemistry, 2006
- Zirconium Phosphonate-Modified Porous Silicon for Highly Specific Capture of Phosphopeptides and MALDI-TOF MS AnalysisJournal of Proteome Research, 2006
- Disposable Hydrophobic Surface on MALDI Targets for Enhancing MS and MS/MS Data of PeptidesAnalytical Chemistry, 2005
- Simple fabrication of a structured matrix‐assisted laser desorption/ionization target coating for increased sensitivity in mass spectrometric analysis of membrane proteinsRapid Communications in Mass Spectrometry, 2004
- Desorption/ionization on silicon (DIOS) mass spectrometry: background and applicationsInternational Journal of Mass Spectrometry, 2003
- Prestructured MALDI-MS Sample SupportsAnalytical Chemistry, 2000
- Desorption–ionization mass spectrometry on porous siliconNature, 1999