Evaluation of Four Bedside Test Systems for Card Performance, Handling and Safety
- 3 December 2007
- journal article
- Published by S. Karger AG in Transfusion Medicine and Hemotherapy
- Vol. 35 (1) , 33-36
Abstract
Objective: Pretransfusion ABO compatibility testing is a simple and required precaution against ABO-incompatible transfusion, which is one of the greatest threats in transfusion medicine. While distinct agglutination is most important for correct test interpretation, protection against infectious diseases and ease of handling are crucial for accurate test performance. Therefore, the aim of this study was to evaluate differences in test card design, handling, and user safety. Design: Four different bedside test cards with pre-applied antibodies were evaluated by 100 medical students using packed red blood cells of different ABO blood groups. Criteria of evaluation were: agglutination, labelling, handling, and safety regarding possible user injuries. Criteria were rated subjectively according to German school notes ranging from 1 = very good to 6 = very bad/insufficient. Results: Overall, all cards received very good/good marks. The ABO blood group was identified correctly in all cases. Three cards (no. 1, no. 3, no. 4) received statistically significant (p < 0.008) prominence (mean values shown) concerning clearness of agglutination (1.7-1.9 vs. 2.4 for no. 2). Systems with dried antibodies (no. 2, no. 4) outmatched the other systems with respect to overall test system performance (2.0 vs. 2.8-2.9), labelling (1.5 vs. 2.2-2.4), handling (1.9-2.0 vs. 2.5), and user safety (2.5 vs. 3.4). Analysis of card self-explanation revealed no remarkable differences. Conclusion: Despite good performance of all card systems tested, the best results when including all criteria evaluated were obtained with card no. 4 (particularly concerning clear agglutination), followed by cards no. 2, no. 1, and no. 3.Keywords
This publication has 17 references indexed in Scilit:
- Prevention of bedside errors in transfusion medicine (PROBE‐TM) study: a cluster‐randomized, matched‐paired clinical areas trial of a simple intervention to reduce errors in the pretransfusion bedside checkTransfusion, 2007
- Failure of bedside ABO testing is still the most common cause of incorrect blood transfusion in the Barcode eraTransfusion and Apheresis Science, 2005
- The risk of transfusion to the wrong patient in GermanyTransfusion, 2002
- Human Error: The Persisting Risk of Blood Transfusion: A Report of Five CasesAnesthesia & Analgesia, 2002
- Non-infectious complications of transfusion therapyBlood Reviews, 2001
- Analyse des risques immunologiques en transfusion sanguine: Période 1991–1998Transfusion Clinique et Biologique, 2000
- Errors in Interpreting the Pretransfusion Bedside Compatibility TestVox Sanguinis, 2000
- La vérification ultime au lit du malade: résultats d'une enquête nationale sur les réactifs et dispositifs utilisés en FranceTransfusion Clinique et Biologique, 1998
- A report of 104 transfusion errors in New York StateTransfusion, 1992
- AB0-Identitätssicherung - Bed-Side-Test - mit einem neuen SystemAINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie, 1980