Abstract
All studies were approved by the University of New South Wales ethics committee. Male Sprague-Dawley rats (350–450 mg) were anaesthetised using ketamine and xylazine in the standard manner. A midline incision was made, and access to the left common carotid artery achieved using standard surgical techniques. The vessel was then isolated from the surrounding tissues, and an arteriotomy performed. A 2.0 × 7 mm BiodivYsio human coronary stent (Abbott Vascular, Illinois, USA) was then advanced into the vessel after topical application of 3–5 drops of glyceryl trinitrate (100 μg/ml). No fluoroscopic guidance was used. At a pre-marked point corresponding to the lower thoracic aorta, the stent was deployed using a single inflation at 16 atmospheres for 10 seconds. The stent balloon was then withdrawn, and post-deployment dilatation performed using a 3.0 × 15 mm coronary angioplasty balloon (Boston Scientific, Boston, Massachusetts, USA) advanced in a similar manner, and inflated to 16 atmospheres for 10 seconds. Before the procedure, the shafts of both stent and post-deployment dilation balloon were marked, comparing to surface anatomy. This ensured they both corresponded to the lower thoracic aorta, and that the post-dilation balloon would lie in the centre of the deployed stent.