Intubation Biomechanics
Open Access
- 1 August 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 121 (2) , 260-271
Abstract
Introduction: Laryngoscopy and endotracheal intubation in the presence of cervical spine instability may put patients at risk of cervical cord injury. Nevertheless, the biomechanics of intubation (cervical spine motion as a function of applied force) have not been characterized. This study characterized and compared the relationship between laryngoscope force and cervical spine motion using two laryngoscopes hypothesized to differ in force. Methods: Fourteen adults undergoing elective surgery were intubated twice (Macintosh, Airtraq). During each intubation, laryngoscope force, cervical spine motion, and glottic view were recorded. Force and motion were referenced to a preintubation baseline (stage 1) and were characterized at three stages: stage 2 (laryngoscope introduction); stage 3 (best glottic view); and stage 4 (endotracheal tube in trachea). Results: Maximal force and motion occurred at stage 3 and differed between the Macintosh and Airtraq: (1) force: 48.8 ± 15.8 versus 10.4 ± 2.8 N, respectively, P = 0.0001; (2) occiput-C5 extension: 29.5 ± 8.5 versus 19.1 ± 8.7 degrees, respectively, P = 0.0023. Between stages 2 and 3, the motion/force ratio differed between Macintosh and Airtraq: 0.5 ± 0.2 versus 2.0 ± 1.4 degrees/N, respectively; P = 0.0006. Discussion: The relationship between laryngoscope force and cervical spine motion is: (1) nonlinear and (2) differs between laryngoscopes. Differences between laryngoscopes in motion/force relationships are likely due to: (1) laryngoscope-specific cervical extension needed for intubation, (2) laryngoscope-specific airway displacement/deformation needed for intubation, and (3) cervical spine and airway tissue viscoelastic properties. Cervical spine motion during endotracheal intubation is not directly proportional to force. Low-force laryngoscopes cannot be assumed to result in proportionally low cervical spine motion.Keywords
This publication has 34 references indexed in Scilit:
- Comparison of 4 Airway Devices on Cervical Spine Alignment in a Cadaver Model With Global Ligamentous Instability at C5–C6Spine, 2012
- Thiel-fixation preserves the non-linear load–deformation characteristic of spinal motion segments, but increases their flexibilityJournal of the Mechanical Behavior of Biomedical Materials, 2011
- Cervical Spine MotionAnesthesiology, 2009
- In situ measurement and modeling of biomechanical response of human cadaveric soft tissues for physics-based surgical simulationSurgical Endoscopy, 2008
- Craniocervical Motion during Direct Laryngoscopy and Orotracheal Intubation with the Macintosh and Miller BladesAnesthesiology, 2007
- Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard™ laryngoscopes, the Bonfils fibrescope and the Intubating Laryngeal Mask AirwayEuropean Journal of Anaesthesiology, 2004
- Load-displacement properties of the normal and injured lower cervical spine in vitroEuropean Spine Journal, 2000
- Assessment of laryngeal view: Percentage of glottic opening scorevs Cormack and Lehane gradingCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1999
- Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard™ laryngoscopes, the Bonfils fibrescope and the Intubating Laryngeal Mask Airway1999
- Spinal immobilization on a flat backboard: Does it result in neutral position of the cervical spine?Annals of Emergency Medicine, 1991