DWDavid J. Wallace

David J. Wallace

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David J. Wallace has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Decreasing the Pedicle Screw Misplacement Rate in the Thoracic Spine With Robot-guided Navigation

    by Arnold B. Vardiman, David J. Wallace, Grant A. Booher, Nader Toossi, Brandon S. Bucklen

    Study Design: A retrospective chart review. Objective: The aim of this study was to evaluate the screw accuracy of thoracic pedicle screws placed with a robot-guided navigation system. Summary of Background Data: Thoracic pedicles are smaller in diameter than lumbar pedicles, making pedicle screw placement difficult. Misplaced pedicle screws may present complications including decreased construct stability, and increased risks of neurological deficits and blood vessel perforation. There is a dearth of knowledge on thoracic pedicle screw accuracy placed with a robot. Materials and Methods: A retrospective analysis of the robot-assisted placement of thoracic pedicle screws was performed. Preoperative and postoperative computed tomography (CT) scans of the implanted thoracic screws were collected to assess screw placement accuracy, pedicle breadth, and placement deviations. A CT-based Gertzbein and Robbins System was used to classify pedicle screw accuracy in 2 mm increments. A custom image overlay software was used to determine the deviations between the preoperatively planned trajectory of pedicle screws and final placement at screw entry (tail), and tip in addition to the angular deviation. Results: Seventy-five thoracic pedicle screws were implanted by navigated robotic guidance in 17 patients, only 1.3% (1/75) were repositioned intraoperatively. Average patient age and body mass index were 57.5 years and 25.9 kg/m2, respectively, with 52.9% female patients. Surgery diagnoses were degenerative disk disease (47.1%) and adjacent segment disease (17.6%). There were zero complications, with no returns to the operating room. According to the CT-based Gertzbein and Robbins pedicle screw breach classification system, 93.3% (70/75) screws were grade A or B, 6.6% (5/75) were grade C, and 0% were grade D or E. The average deviation from the preoperative plan to actual final placement was 1.8±1.3 mm for the screw tip, 1.6±0.9 mm for the tail, and 2.1±1.5 degrees of angulation. Conclusions: The current investigation found a 93.3% accuracy of pedicle screw placement in the thoracic spine. Navigated robot assistance is a useful system for placing screws in the smaller pedicles of the thoracic spine. Level of Evidence: Level III—retrospective nonexperimental study.


  • Open Access

    Inhibition of astrocyte hemichannel improves recovery from spinal cord injury

    by Chao Zhang, Zhao Yan, Asif Maknojia, Manuel A. Riquelme, Sumin Gu, Grant Booher, David J. Wallace, Viktor Bartanusz, Akshay Goswami, Wei Xiong, et al.

    Spinal cord injury (SCI) causes severe disability, and the current inability to restore function to the damaged spinal cord leads to lasting detrimental consequences to patients. One strategy to reduce SCI morbidity involves limiting the spread of secondary damage after injury. Previous studies have shown that connexin 43 (Cx43), a gap junction protein richly expressed in spinal cord astrocytes, is a potential mediator of secondary damage. Here, we developed a specific inhibitory antibody, mouse-human chimeric MHC1 antibody (MHC1), that inhibited Cx43 hemichannels, but not gap junctions, and reduced secondary damage in 2 incomplete SCI mouse models. MHC1 inhibited the activation of Cx43 hemichannels in both primary spinal astrocytes and astrocytes in situ. In both SCI mouse models, administration of MHC1 after SCI significantly improved hind limb locomotion function. Remarkably, a single administration of MHC1 30 minutes after injury improved the recovery up to 8 weeks post-SCI. Moreover, MHC1 treatment decreased gliosis and lesion sizes, increased white and gray matter sparing, and improved neuronal survival. Together, these results suggest that inhibition of Cx43 hemichannel function after traumatic SCI reduces secondary damage, limits perilesional gliosis, and improves functional recovery. By targeting hemichannels specifically with an antibody, this study provides a potentially new, innovative therapeutic approach in treating SCI.


  • Open Access

    Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery?

    by Arnold B. Vardiman, David J. Wallace, Grant A. Booher, Neil R. Crawford, Jessica R. Riggleman, Samantha L. Greeley, Charles G. Ledonio

    Robotic assistance with integrated navigation is an area of high interest for improving the accuracy of minimally invasive pedicle screw placement. This study analyzes the accuracy of pedicle screw placement between an attending spine surgeon and a resident by comparing the left and right sides of the first 101 consecutive cases using navigated robotic assistance in a private practice clinical setting. A retrospective, Institutional Review Board-exempt review of the first 106 navigated robot-assisted spine surgery cases was performed. One attending spine surgeon and one resident performed pedicle screw placement consistently on either the left or right side (researchers were blinded). A CT-based Gertzbein and Robbins system (GRS) was used to classify pedicle screw accuracy, with grade A or B considered accurate. There were 630 consecutive lumbosacral pedicle screws placed. Thirty screws (5 patients) were placed without the robot due to surgeon discretion. Of the 600 pedicle screws inserted by navigated robotic guidance (101 patients), only 1.5% (9/600) were repositioned intraoperatively. Based on the GRS CT-based grading of pedicle breach, 98.67% (296/300) of left-side screws were graded A or B, 1.3% (4/300) were graded C, and 0% (0/300) were graded D. For the right-side screws, 97.67% (293/300) were graded A or B, 1.67% (5/300) were graded C, and 0.66% (2/300) were graded D. This study demonstrated a high level of accuracy (based on GRS) with no significant differences between the left- and right-side pedicle screw placements (98.67% vs. 97.67%, respectively) in the clinical use of navigated, robot-assisted surgery.


  • Open Access

    Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgery

    by Arnold B. Vardiman, David J. Wallace, Neil R. Crawford, Jessica R. Riggleman, Leigh A. Ahrendtsen, Charles G. Ledonio

    In the emerging field of robot-assisted spine surgery, the radiographic evaluation of pedicle screw accuracy in clinical application is an area of high interest. This study describes the pedicle screw accuracy of the first 56 consecutive cases in which navigated robotic assistance was used in a private practice clinical setting. A retrospective, Institutional Review Board-exempt review of the first 56 navigated robot-assisted spine surgery cases was performed. Pedicle screw malposition, reposition, and return to operating room (OR) rates were collected. A CT-based Gertzbein and Robbins system (GRS) was used to classify pedicle screw accuracy. In the first 56 robotic cases, 356 total pedicle screws were placed. Eight screws were placed without the robot due to surgeon discretion. Of the 348 pedicle screws inserted by navigated robotic guidance, only 2.6% (9/348) were repositioned, resulting in a 97.4% (339/348) successful screw placement rate. The average age was 64, and 48% were female. Average body mass index was 31 kg/m2. Based on the GRS CT-based grading, 97.7% (340/348) were graded A or B, 1.7% (6/348) screws were graded C, and only 0.6% (2/348) of screws were graded D. Two complications, explantation of interbody and vacuum-assisted wound closure, were reported as requiring a return to the OR, but these were not related to robotic guidance or pedicle screws. This study demonstrated a high level of accuracy (97.7%) in the first 56 cases using navigated, robot-assisted surgery based on the GRS. There were two non-screw-related complications requiring return to the operating room.


  • Spinal cord injury and the human microbiome: beyond the brain–gut axis

    by David J. Wallace, Naomi L. Sayre, T. Tyler Patterson, Susannah E. Nicholson, Donald Hilton, Ramesh Grandhi

    In addition to standard management for the treatment of the acute phase of spinal cord injury (SCI), implementation of novel neuroprotective interventions offers the potential for significant reductions in morbidity and long-term health costs. A better understanding of the systemic changes after SCI could provide insight into mechanisms that lead to secondary injury. An emerging area of research involves the complex interplay of the gut microbiome and the CNS, i.e., a brain–gut axis, or perhaps more appropriately, a CNS–gut axis. This review summarizes the relevant literature relating to the gut microbiome and SCI. Experimental models in stroke and traumatic brain injury demonstrate the bidirectional communication of the CNS to the gut with postinjury dysbiosis, gastrointestinal-associated lymphoid tissue–mediated neuroinflammatory responses, and bacterial-metabolite neurotransmission. Similar findings are being elucidated in SCI as well. Experimental interventions in these areas have shown promise in improving functional outcomes in animal models. This commensal relationship between the human body and its microbiome, particularly the gut microbiome, represents an exciting frontier in experimental medicine.


  • Management of non-missile penetrating spinal injury

    by David J. Wallace, Christopher Sy, Geoffrey Peitz, Ramesh Grandhi

    Review of the literature with case illustration. Non-missile penetrating spinal injury (NPSI) represents a small subset of spinal cord injuries at tertiary trauma centers and is comprised mostly of knife violence. Strict guidelines for the management of penetrating spinal cord injury remain elusive given the variability of mechanisms, rarity of clinical experience, and paucity of prospective studies. A review of the literature was conducted by search of the National Library of Medicine (PubMed) in the English language through June of 2018. Additional articles were culled from the reference lists of the included series. Eleven case series totaling 1007 patients, along with 21 case reports, were identified. In summary, magnetic resonance imaging (MRI) may be beneficial in assessing incomplete or progressive spinal injuries and can be considered with retained foreign bodies in select cases. Forty-eight hours of antibiotic prophylaxis is likely sufficient to prevent infection. Puncture wounds should be debrided, washed, and closed. Retained foreign bodies should be removed in the operating room and often require laminectomy. Early intervention is preferred. Non-missile penetrating spinal injury has a higher likelihood of neurologic recovery as compared to other traumatic spinal injuries.


  • Bone flap salvage in acute surgical site infection after craniotomy for tumor resection

    by David J. Wallace, Michael J. McGinity, John R. Floyd

    Craniotomy surgical site infections are an inherent risk and dreaded complication for the elective brain tumor patient. Sequelae can include delays in resumption in adjuvant treatments for multiple surgeries if staged cranioplasty is pursued. Here, the authors review their experience in operative debridement of surgical site infections with single-stage reimplantation of the salvaged craniotomy bone flap. A prospectively maintained database of a single surgeon’s neuro-oncology patients from 2009 to 2017 (JRF) was queried to identify 11 patients with surgical site infection after craniotomy for tumor resection. All patients underwent a protocol of aggressive operative debridement including drilling the bone edges and intraoperative flap sterilization with single-stage reimplantation, followed by tailored-antibiotic therapy. Ten of the 11 patients with frankly contaminated bone flaps from surgical site infection were able to be salvaged in a single-stage procedure. Five of these patients underwent adjuvant chemotherapy and/or radiation without secondary complication. There was one treatment failure in a delayed fashion which required additional surgery for craniectomy; however, this occurred after adjuvant treatment was administered. Surgical debridement and bone flap salvage is safe and cost-effective in managing acute surgical site infections after craniotomy for tumors. Additionally, this practice is likely beneficial in expediting the resumption of cancer therapy.