Quantification of the Glycemic Response to Microdoses of Subcutaneous Glucagon at Varying Insulin Levels
Open Access
- 10 October 2014
- journal article
- research article
- Published by American Diabetes Association in Diabetes Care
- Vol. 37 (11) , 3054-3060
Abstract
OBJECTIVE: Glucagon delivery in closed-loop control of type 1 diabetes is effective in minimizing hypoglycemia. However, high insulin concentration lowers the hyperglycemic effect of glucagon, and small doses of glucagon in this setting are ineffective. There are no studies clearly defining the relationship between insulin levels, subcutaneous glucagon, and blood glucose. RESEARCH DESIGN AND METHODS: Using a euglycemic clamp technique in 11 subjects with type 1 diabetes, we examined endogenous glucose production (EGP) of glucagon (25, 75, 125, and 175 μg) at three insulin infusion rates (0.016, 0.032, and 0.05 units/kg/h) in a randomized, crossover study. Infused 6,6-dideuterated glucose was measured every 10 min, and EGP was determined using a validated glucoregulatory model. Area under the curve (AUC) for glucose production was the primary outcome, estimated over 60 min. RESULTS: At low insulin levels, EGP rose proportionately with glucagon dose, from 5 ± 68 to 112 ± 152 mg/kg (P = 0.038 linear trend), whereas at high levels, there was no increase in glucose output (19 ± 53 to 26 ± 38 mg/kg, P = NS). Peak glucagon serum levels and AUC correlated well with dose (r2 = 0.63, P < 0.001), as did insulin levels with insulin infusion rates (r2 = 0.59, P < 0.001). CONCLUSIONS: EGP increases steeply with glucagon doses between 25 and 175 μg at lower insulin infusion rates. However, high insulin infusion rates prevent these doses of glucagon from significantly increasing glucose output and may reduce glucagon effectiveness in preventing hypoglycemia when used in the artificial pancreas.Keywords
This publication has 47 references indexed in Scilit:
- Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: a randomized crossover controlled trialCanadian Medical Association Journal, 2013
- Validity of triple- and dual-tracer techniques to estimate glucose appearanceAmerican Journal of Physiology-Endocrinology and Metabolism, 2012
- Minireview: Glucagon in the Pathogenesis of Hypoglycemia and Hyperglycemia in DiabetesEndocrinology, 2012
- Glucagonocentric restructuring of diabetes: a pathophysiologic and therapeutic makeoverJournal of Clinical Investigation, 2012
- Normal Glucagon Signaling and β-Cell Function After Near-Total α-Cell Ablation in Adult MiceDiabetes, 2011
- Artificial Pancreas: Past, Present, FutureDiabetes, 2011
- A Bihormonal Closed-Loop Artificial Pancreas for Type 1 DiabetesScience Translational Medicine, 2010
- Novel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 DiabetesDiabetes Care, 2010
- MD-Logic Artificial Pancreas SystemDiabetes Care, 2010
- Closed-Loop Insulin Delivery Using a Subcutaneous Glucose Sensor and Intraperitoneal Insulin DeliveryDiabetes Care, 2009