The ideal site of cement application in cement augmented sacroiliac screw fixation: the biomechanical perspective
Open Access
- 12 December 2022
- journal article
- research article
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 49 (3) , 1449-1458
Abstract
Purpose: To compare construct stability of cement augmented sacroiliac screws using two different cementation sites in a biomechanical fragility fracture model of the pelvis.Methods: A fracture model with an incomplete fracture of the sacral ala and complete fracture of the anterior pelvic ring mimicking a FFP IIB fragility fracture of the pelvis was established in five fresh frozen human cadaveric pelvises. Sacral fracture stabilization was achieved with bilateral 7.3 mm fully threaded sacroiliac screws. Cement augmentation was performed at the tip of the screw (body of S1; Group A) on one side, and at the midshaft of the screw (sacral ala; Group B) on the contralateral side. Biomechanical testing was conducted separately on both sides comprising cyclic loading of axial forces transferred through the tested hemipelvis from L5 to the ipsilateral acetabulum. Combined angular displacement in flexion and internal rotation (“gap angle”), angular displacement of the ilium in relation to the screw (“screw tilt ilium”), and screw tip cutout were evaluated.Results: Relative interfragmentary movements were associated with significantly higher values in group A versus group B for “gap angle” (2.4° vs. 1.4°;p < 0.001), and for “screw tilt ilium” (3.3° vs. 1.4°;p < 0.001), respectively. No significant difference was indicated for screw tip cutout between the two groups (0.6 mm [Group A] vs. 0.8 mm [Group B];p = 0.376).Conclusion: The present study demonstrated less fragment and screw displacements in a FFP IIB fracture model under physiologic cyclic loading by cement augmentation of sacroiliac screws at the level of the lateral mass compared to the center of vertebral body of S1.Keywords
Funding Information
- University of Bern
This publication has 55 references indexed in Scilit:
- Surgical management of osteoporotic pelvic fractures: a new challengeEuropean Journal of Trauma and Emergency Surgery, 2012
- Anatomical and Biomechanical Analyses of the Unique and Consistent Locations of Sacral Insufficiency FracturesSpine, 2009
- Mechanical analysis of percutaneous sacroplasty using CT image based finite element modelsMedical Engineering & Physics, 2006
- Percutaneous Sacroplasty: Long-Axis Injection TechniqueAmerican Journal of Roentgenology, 2006
- Closed pelvic fractures: characteristics and outcomes in older patients admitted to medical and geriatric wardsPostgraduate Medical Journal, 2000
- Factors Affecting the Pullout Strength of Cancellous Bone ScrewsJournal of Biomechanical Engineering, 1996
- Radiographic Recognition of the Sacral Alar Slope for Optimal Placement of Iliosacral Screws: A Cadaveric and Clinical StudyJournal of Orthopaedic Trauma, 1996
- The Effects of Depth of Penetration, Screw Orientation, and Bone Density on Sacral Screw FixationSpine, 1993
- Anatomic and experimental basis for the insertion of a screw at the first sacral vertebraSurgical and Radiologic Anatomy, 1991
- Sacral FracturesClinical Orthopaedics and Related Research, 1988