Evaluation of a commercial biologically based IMRT treatment planning system
Authors:
- Vladimir A. SemenenkoVSVladimir A. Semenenko
- Bodo ReitzBRBodo Reitz
- Ellen DayEDEllen Day
- X. Sharon QiXQX. Sharon Qi
- Moyed MiftenMMMoyed Miften
- X. Allen LiXLX. Allen Li
- 21 November 2008
- journal article
- Published by Wiley in Medical Physics
- Vol. 35 (12) , 5851-5860
Abstract
A new inverse treatment planning system (TPS) for external beam radiation therapy with high energy photons is commercially available that utilizes both dose‐volume‐based cost functions and a selection of cost functions which are based on biological models. The purpose of this work is to evaluate quality of intensity‐modulated radiation therapy (IMRT) plans resulting from the use of biological cost functions in comparison to plans designed using a traditional TPS employing dose‐volume‐based optimization. Treatment planning was performed independently at two institutions. For six cancer patients, including head and neck (one case from each institution), prostate, brain, liver, and rectal cases, segmental multileaf collimator IMRT plans were designed using biological cost functions and compared with clinically used dose‐based plans for the same patients. Dose‐volume histograms and dosimetric indices, such as minimum, maximum, and mean dose, were extracted and compared between the two types of treatment plans. Comparisons of the generalized equivalent uniform dose (EUD), a previously proposed plan quality index , target conformity and heterogeneity indices, and the number of segments and monitor units were also performed. The most prominent feature of the biologically based plans was better sparing of organs at risk (OARs). When all plans from both institutions were combined, the biologically based plans resulted in smaller EUD values for 26 out of 33 OARs by an average of (range ). Owing to more efficient beam segmentation and leaf sequencing tools implemented in the biologically based TPS compared to the dose‐based TPS, an estimated treatment delivery time was shorter in most (five out of six) cases with some plans showing up to 50% reduction. The biologically based plans were generally characterized by a smaller conformity index, but greater heterogeneity index compared to the dose‐based plans. Overall, compared to plans based on dose‐volume optimization, plans with equivalent target coverage obtained using the biologically based TPS demonstrate improved dose distributions for the majority of normal structures.Keywords
This publication has 39 references indexed in Scilit:
- Comparison of IMRT planning with two-step and one-step optimization: a way to simplify IMRTPhysics in Medicine & Biology, 2008
- A finite size pencil beam algorithm for IMRT dose optimization: density correctionsPhysics in Medicine & Biology, 2007
- 2800: Ranking Complex IMRT Plans Using an EUD-Based Figure-of-Merit IndexInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Benefit of using biologic parameters (EUD and NTCP) in IMRT optimization for treatment of intrahepatic tumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- A finite size pencil beam for IMRT dose optimizationPhysics in Medicine & Biology, 2005
- Classification of breast tissue density by optical transillumination spectroscopy: Optical and physiological effects governing predictive valueMedical Physics, 2004
- Tools for the analysis of dose optimization: II. Sensitivity analysisPhysics in Medicine & Biology, 2002
- Optimization of the Dose Level for a Given Treatment Plan to Maximize the Complication-free Tumor CureActa Oncologica, 1999
- Reporting and analyzing dose distributions: A concept of equivalent uniform doseMedical Physics, 1997
- Optimization of intensity-modulated 3D conformal treatment plans based on biological indicesRadiotherapy and Oncology, 1995