Abstract
To improve the dielectric strength in vacuum, spark conditioning through repetitive breakdowns by ac voltage application is an effective method. High frequency ac conditioning is expected for the higher dielectric strength after conditioning, but the optimized frequency and other conditions for the effective ac conditioning have not been clarified. In this paper, applied ac voltage frequency and electrode material were investigated as parameters for the dielectric strength improvement by ac conditioning. High frequency ac conditioning was conducted for the stainless steel (SUS) electrodes and compared it with that for the Cu electrodes. Experimental results revealed that the high frequency ac conditioning improved the dielectric strength by 13% at 550 Hz for the Cu electrodes, but did not almost improve for the SUS electrodes. For the electrode materials with high electrical conductivity, such as Cu, harmful effects of the unnecessary or multiple breakdowns during conventional or low frequency ac conditioning would be relatively large. Thus, the high frequency ac conditioning can be effective for the electrode materials with high electrical conductivity due to the suppression of the multiple breakdowns. Secondly, impulse conditioning with shot-by-shot polarity reversal, i.e. no unnecessary or multiple breakdowns, was carried out in order to simulate the same condition as the optimized frequency of ac conditioning. As a result, the impulse breakdown voltage after impulse conditioning was similar to that after 550 Hz ac conditioning. This result suggests that high frequency ac conditioning can be sufficiently effective by increasing the ac voltage frequency from 60 Hz to 550 Hz.