NHNaoki Hayakawa

Naoki Hayakawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Naoki Hayakawa has a total of 76 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dynamic Breakdown Characteristics of Liquid Nitrogen for Superconducting Fault Current Limiters in Multi-Terminal HVDC Systems

    by N. Hayakawa, D. Nishizawa, K. Naganawa, H. Kojima

    In multi-terminal HVDC systems, superconducting fault current limiters (SFCL) are expected to suppress large fault currents to improve the system stability and to reduce the DC circuit breaker responsibilities. There is a risk of dynamic breakdown of liquid nitrogen (LN2) under bubble disturbance during SFCL operation. In previous studies, dynamic breakdown properties of LN2 have been obtained under AC electric field. In this study, the pressure dependence of dynamic breakdown characteristics of LN2 under DC electric field for resistive-SFCL (RSFCL) in multi-terminal HVDC systems are obtained. As a result, using a pancake coil model in LN2, the dynamic breakdown strength under positive DC electric field was lower than that under AC or negative DC electric field, but improved in the pressurized LN2. Supposing that SFCLs were introduced in a multi-terminal HVDC system model, the operation of SFCL was evaluated for different fault locations. This paper will contribute to efficient electrical insulation design of RSFCL and reliable operation of future multi-terminal HVDC systems

  • Electrical Insulation Characteristics of Stationary and Streaming Lubricating Oil toward High Power Density Motors for Electric Powered Aircraft

    by Naoki Hayakawa, Shimpei Noguchi, Hiroki Kojima, Nobuo Aruga, Kiyoshi Utatsu, Shunya Watanabe

    The authors aim to apply a lubricating oil used for cooling motor windings to an insulating material to improve the dielectric strength of motors for electric powered aircraft. Electric powered aircraft motors flying at high altitude require high environmental resistance and reliability. There exists an oil flow and temperature rise in the lubricating oil to cool the motor windings. During a cold start in a cold environment, the lubricating oil is exposed to low temperatures. During long-term use, the lubricating oil can undergo thermal aging. Therefore, dielectric strength of the lubricating oil for different operating conditions is investigated in this paper. Firstly, ac breakdown voltage (BDV) of stationary lubricating oil with controlled moisture content of 8–52% was measured, and the moisture content dependence of breakdown electric field strength (BDE) was discussed in consideration of the volume effect (100–105 mm3) of BDE. The results suggest that the decrease in BDE due to the volume effect would be more dominant than that due to the moisture effect. Secondly, ac BDV of streaming lubricating oil was measured at the flow rate of 0–38 L/min and the temperature of 23–65 °C. As a result, the BDV of streaming lubricating oil was 24–55% higher than that of stationary oil at different temperatures. Also, the BDV at low flow rates decreased as temperature increased. Thirdly, ac BDV of lubricating oil was measured under low temperature conditions (-40–25 °C). The BDV of lubricating oil under low temperature conditions exhibited a temporary decrease during the temperature rise process, indicating the necessity of warm-up operation. Finally, ac BDV of lubricating oil under thermal aging was measured. Under thermal aging, the lubricating oil exhibited minimal sludge formation and stable BDV, indicating high resistance to thermal aging. The results suggest that the dielectric strength of lubricating oil could be applicable to higher voltage and higher power density design and operation for electric powered aircraft motors.

  • Effective High-Frequency AC Conditioning in Vacuum

    by Ryota Konagi, Hiroki Kojima, Shinsuke Iitsuka, Masato Kobayashi, Naoki Hayakawa

    To improve the dielectric strength in vacuum, spark conditioning through repetitive breakdowns by ac voltage application is an effective method. High frequency ac conditioning is expected for the higher dielectric strength after conditioning, but the optimized frequency and other conditions for the effective ac conditioning have not been clarified. In this paper, applied ac voltage frequency and electrode material were investigated as parameters for the dielectric strength improvement by ac conditioning. High frequency ac conditioning was conducted for the stainless steel (SUS) electrodes and compared it with that for the Cu electrodes. Experimental results revealed that the high frequency ac conditioning improved the dielectric strength by 13% at 550 Hz for the Cu electrodes, but did not almost improve for the SUS electrodes. For the electrode materials with high electrical conductivity, such as Cu, harmful effects of the unnecessary or multiple breakdowns during conventional or low frequency ac conditioning would be relatively large. Thus, the high frequency ac conditioning can be effective for the electrode materials with high electrical conductivity due to the suppression of the multiple breakdowns. Secondly, impulse conditioning with shot-by-shot polarity reversal, i.e. no unnecessary or multiple breakdowns, was carried out in order to simulate the same condition as the optimized frequency of ac conditioning. As a result, the impulse breakdown voltage after impulse conditioning was similar to that after 550 Hz ac conditioning. This result suggests that high frequency ac conditioning can be sufficiently effective by increasing the ac voltage frequency from 60 Hz to 550 Hz.


  • Partial Discharge Progress and Breakdown Characteristics of Oil-Impregnated Paper Insulation System for Capacitor Voltage Transformers

    by Yuya Nagaki, Kyohei Hayashi, Hiroki Kojima, Masanobu Yoshida, Naoki Hayakawa

    Capacitor voltage transformers (CVTs) with aluminum foil/oil-impregnated papers composite insulation system have been operated over 30 years in substations. An insulation diagnosis of CVT is expected to be based on detecting partial discharge (PD). However, PD characteristics from PD inception to breakdown (BD) have not been clarified yet. In an insulation diagnosis of CVT, it is necessary to diagnose a risk level of BD based on PD characteristics. In this paper, we investigated the PD characteristics using electrical and optical measurement on the fundamental insulation model of CVT and discussed the PD progress characteristics leading to BD. Experimental results revealed that PD, which was generated from the aluminum foil electrode periphery, progressed from the creeping direction to the penetrating direction of the oil-impregnated papers, and then BD occurred. When PD penetrated the oil-impregnated paper, PD charge increased, and hydrogen-based gas was generated. This PD progress can be an important factor to establish insulation diagnosis based on PD measurement of CVT.


  • Breakdown Charge Dependence of Counter Electrode Material Adhesion and Dielectric Strength After Spark Conditioning in Vacuum

    by Naoki Kita, Hiroki Kojima, Naoki Hayakawa, Hideaki Fukuda, Kenta Yamamura, Kazuhiro Nagatake

    Spark conditioning is an effective method of increasing the dielectric strength in vacuum. In this paper, we discuss the breakdown (BD) charge dependence of counter electrode material adhesion and dielectric strength after spark conditioning. We have applied a negative impulse voltage to a rod-plane electrode configuration with a cathode and an anode made of stainless steel (SUS) that is defined as SUS304 by JIS G 4303 or oxygen free high conductivity copper (Cu). The electrode system of cathode SUS and anode Cu is called SUS-Cu electrode system, and the electrode system of cathode Cu and anode SUS is called Cu-SUS electrode system. We have changed BD charge (QBD) in conditioning by changing the limiting resistance in the experimental circuit. As a result, in both cases of SUS-Cu and Cu-SUS electrode systems, the larger the QBD, the smaller the amount of the anode material adhered to the cathode surface. When QBD is large, the dielectric strength increases in SUS-Cu electrode system and decreases in Cu-SUS electrode system. From these results, when QBD is large, we consider that the conditioning characteristics are less likely to be dominated by the anode material, i.e. Cu in the case of SUS-Cu electrode system and SUS in the case of Cu-SUS electrode system. In other words, the decisive parameters such as QBD to maximize the dielectric strength may depend on the combination of electrode materials.


  • Electric Field Grading and Discharge Inception Voltage Improvement on HVDC GIS/GIL Spacer With Permittivity and Conductivity Graded Materials (ε/σ-FGM)

    by Rachmawati, Hiroki Kojima, Katsumi Kato, Nabila Zebouchi, Naoki Hayakawa

    Functionally graded materials (FGM) application with graded permittivity and conductivity is promising as an effective technique for electric field relaxation in SF6 gas around HVDC gas insulated switchgear (GIS)/gas insulated transmission line (GIL) spacers. To approach the practical application of FGM to HVDC GIS/GIL spacers, this article investigates the electric field reduction effect given by permittivity and conductivity graded materials ( $\varepsilon /\sigma $ -FGM) based on actual measured permittivity ( $\varepsilon $ ) characteristics of SrTiO3-filled epoxy composites and conductivity ( $\sigma $ ) characteristics of SiC-filled epoxy composites. In addition, theoretical discharge inception voltage (TDIV) of $\varepsilon /\sigma $ -FGM spacer is calculated under standard lightning impulse (LI) voltage based on the volume–time theory. The results show that the $\varepsilon /\sigma $ -FGM spacer with grading to lower permittivity (GLP) ( $\varepsilon _{r}$ from 12.7 to 4) containing 0–26.9-vol% SrTiO3-filled epoxy composite and U-shaped graded conductivity containing 5–10-vol% SiC-filled epoxy composite is effective for electric field relaxation under DC steady state (DC-SS) and LI voltage where both resistive and capacitive fields present. It is attributed to the higher $\varepsilon $ and $\sigma $ of FGM spacer near the HV conductor/spacer interface. TDIV under LI voltage is also estimated to be 26% higher at 0.5 MPa-abs, compared with the conventional spacer without $\varepsilon /\sigma $ grading.


  • Melting and Generation of Micro-Protrusions on Cathode Surface During Spark Conditioning Process in Vacuum

    by Naoki Kita, Fuminori Kondo, Hiroki Kojima, Naoki Hayakawa, Hideaki Fukuda, Kenta Yamamura

    Spark conditioning is an effective method to increase the dielectric strength in vacuum by melting and removing micro-protrusions on the cathode surface. We aim to optimize the conditioning effect in vacuum for the application of vacuum circuit breakers (VCBs) to higher voltage levels. To obtain high breakdown (BD) voltage, the control of BD charge in the conditioning process is required. When a BD occurs, we have suggested that micro-protrusions can be generated on the cathode surface by particles from the anode. For the suitable control of BD charge, the meltability of generated micro-protrusions and their size are important. In this paper, we focus on the generation of micro-protrusions on the cathode surface in conditioning process. First, we conduct spark conditioning by repetitive impulse voltages of rod-plane electrodes made of OFHC Cu in a vacuum chamber with different BD charge. After that, we observe the surface of rod cathode with a digital microscope in order to count the number of visible protrusions and measure their radii. By considering the meltability of micro-protrusions, we quantitatively reveal the existence of residual protrusions that cannot be completely melted by BD. Next, we estimate the maximum size of generated micro-protrusions by BD charge. In consideration of the collision of ions into the anode accelerated by the anode sheath voltage, we estimate the meltable amount of anode material by the BD charge. We confirm that the radii of experimentally measured protrusions are close to the estimated ones. Moreover, we consider the difference in dielectric strength due to the difference in the initial surface condition of the electrodes. We clarify that the dielectric strength is improved by applying acid wash and heat treatment to the electrodes before conditioning, which can be optimized by the BD charge and the initial surface condition of the electrode.


  • Volume Effect of Dynamic Breakdown Strength in Liquid Nitrogen Under Transient Bubble Disturbance for Resistive Superconducting Fault Current Limiters

    by Naoki Hayakawa, Yuji Mori, Hiroki Kojima

    Liquid nitrogen (LN 2 ) is indispensable as the cooling and electrical insulating materials for high-temperature superconducting (HTS) power apparatus. Especially for the resistive superconducting fault current limiters (RSFCLs), a transient bubble disturbance in LN 2 is generated due to the quench of HTS materials, which may induce an electrical breakdown in LN 2 even under the rated voltage of RSFCL. We have been investigating not only the intrinsic breakdown characteristics of LN 2 under the steady-state operation, but also the dynamic breakdown characteristics of LN 2 under the fault current limiting operation of RSFCL. In this article, we investigate the heat flux and pressure dependence of the quench-induced dynamic breakdown characteristics of LN 2 by using an actual HTS conductor and a pancake coil model for RSFCL. In addition, the dynamic breakdown strength is discussed and systematized in terms of the volume effect of breakdown strength in LN 2 . A flowchart to estimate the intrinsic and dynamic breakdown strength in LN 2 is proposed toward the reliable and rational insulation design of RSFCL.


  • Dielectric Characteristics of Liquid Nitrogen/Synthetic Paper Composite Insulation System for Extra High Voltage HTS Cable

    by Naoki Hayakawa, Koki Yamakami, Takato Masuda, Hiroki Kojima

    For extra-high-voltage high-temperature superconducting (HTS) cables, not only high electrical insulation performance but also low dielectric loss is required. Therefore, we focus on a porous synthetic paper with lower dielectric loss, e.g. Tyvek® polyethylene nonwoven fabric, than that of polypropylene laminated paper (PPLP®), which has been used for a conventional HTS cable insulation system. In this paper, we compare partial discharge inception characteristics for different liquid nitrogen/synthetic paper composite insulation systems. The partial discharge inception electric field strength in the composite insulation system depends on the electric field strength in the porous area of synthetic paper.