Clinical validation of high-resolution image reconstruction algorithms in brain 18F-FDG-PET
Authors:
- Akio NagakiANAkio Nagaki
- Masahisa OnoguchiMOMasahisa Onoguchi
- Norikazu MatsutomoNMNorikazu Matsutomo
- 1 December 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 35 (12) , 1224-1232
Abstract
Accurate estimation of radiopharmaceutical uptake in the brain is difficult because of count statistics, low spatial resolution, and smoothing filter. The aim of this study was to assess the counting rate performance of PET scanners and the image quality with different combinations of high-resolution image reconstruction algorithms in brain F-2-fluorodeoxy-D-glucose (F-FDG)-PET. Using 23 patient studies, we analyzed the coincidence rates of true and random, random fraction, and the noise equivalent counts per axial length (NECpatient) in brain and liver bed positions. The reconstruction algorithms were combined with baseline ordered subsets expectation maximization, Gaussian filter (GF), point spread function (PSF), and time-of-flight (TOF). The image quality of the brain cortex was quantitatively evaluated with respect to spatial resolution, contrast, and signal-to-noise ratio (SNR). The true coincidence rate in the brain was higher by 1.86 times and the random coincidence rate was lower by 0.61 times compared with that in the liver. In the brain, random fraction was lower and NECpatient was higher than that of the liver. Although GF improved the SNR, spatial resolution and contrast were reduced by 12 and 11%, respectively (P<0.01). PSF improved spatial resolution and SNR by 11 and 53%, respectively (P<0.01), and TOF improved SNR by ∼23% (P<0.01). We have demonstrated that a high-resolution image reconstruction algorithm for brain F-FDG-PET is promising without the use of a GF because of high true coincidence counts and that combined with PSF and TOF is optimal for obtaining a better SNR of the image.Keywords
This publication has 22 references indexed in Scilit:
- Multimodality Assessment of Brain Tumors and Tumor RecurrenceJournal of Nuclear Medicine, 2011
- 18F-FDG PET/CT of Patients With Cancer: Comparison of Whole-Body and Limited Whole-Body TechniqueAmerican Journal of Roentgenology, 2010
- Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluationPhysics in Medicine & Biology, 2010
- Impact of Time-of-Flight on PET Tumor DetectionJournal of Nuclear Medicine, 2009
- Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRTEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- 18F-FDG PET and PET/CT in the Evaluation of Cancer Treatment ResponseJournal of Nuclear Medicine, 2009
- Dual-Modality Imaging: Combining Anatomy and FunctionJournal of Nuclear Medicine, 2008
- Recommendations on the Use of 18F-FDG PET in OncologyJournal of Nuclear Medicine, 2008
- Benefit of Time-of-Flight in PET: Experimental and Clinical ResultsJournal of Nuclear Medicine, 2008