Double-layered suturing using a reopenable-clip over-the-line method with a 20-mm reopenable clip to close a large gastric mucosal defect
Authors:
Open Access
- 14 January 2025
- journal article
- e videos
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E1381-E1382
Abstract
Closing large defects left after endoscopic submucosal dissection (ESD) of the upper gastric body is difficult because of the thick muscle layer. We recently developed the reopenable-clip over-the-line method (ROLM) to assist such closure procedures [1] [2] [3]. Furthermore, a 20-mm reopenable clip (LOCKADO clip; 20 mm; Micro-Tech (Nanjing) Co., Ltd, Nanjing, China) with a large opening width has recently become available in Japan [4]. We have now also explored a double-layered ROLM (DL-ROLM) approach that achieves complete closure using a large clip combined with double-layered suturing ([Fig. 1]). The wide, reopenable clip features small protrusions to prevent slippage, allowing it to grab more tissue than conventional clips. Its reopenable function facilitates substantial muscle grasping. We recently treated a patient with a large post-ESD defect left in the stomach’s upper lesser curvature ([Fig. 2] and [Video 1]). Because of significant muscle layer damage we observed during the ESD, we closed the defect entirely, using DL-ROLM. We grasped a large portion of the muscle on the floor of the ulcer and placed the reopenable clip [5]. A second clip was then placed to grasp the folds created by the initial clip, as well as the musculature on the ulcer floor. Additional clips were placed similarly to grasp the regional muscles. Together, the clips held the defect in an oval shape, facilitating further closure using the ROLM approach. Threaded clips were then placed along the edges of the defect. The clips with lines threaded through their teeth were placed on the contralateral edge of the defect. We confirmed endoscopically that the clip had not been buried. The repeated placement of clips with lines threaded through the tooth was then able to completely close the large defect, and the patient was discharged without any adverse events. By folding the muscle over a large mucosal defect, DL-ROLM facilitates ROLM and a more secure closure, potentially extending the duration over which closure is maintained. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 28 November 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, GermanyKeywords
This publication has 5 references indexed in Scilit:
- Closure of gastric mucosal defects using the reopenable-clip over-the-line method to decrease the risk of bleeding after endoscopic submucosal dissection: a multicenter propensity score–matched case-control study (with video)Gastrointestinal Endoscopy, 2024
- Reopenable clip‐over‐the‐line method for closing large mucosal defects following gastric endoscopic submucosal dissection: Prospective feasibility studyDigestive Endoscopy, 2022
- Closure of full-thickness perforations in porcine stomach using 20-mm reopenable clipsEndoscopy, 2022
- Clip-line closure with the reopenable clip over line method for a large mucosal defect after gastric endoscopic submucosal dissectionEndoscopy, 2021
- Endoscopic double-layered suturing: a novel technique for closure of large mucosal defects after endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD)Endoscopy, 2012