Tatsuma Nomura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tatsuma Nomura has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Shinya Sugimoto
Department of Gastroenterology, Ise Red Cross Hospital, Ise, Japan
33 shared publicationsAkira Kamei
Department of Gastroenterology, Ise Red Cross Hospital, Ise, Japan
31 shared publicationsJun Oyamada
Department of Gastroenterology, Ise Red Cross Hospital, Ise, Japan
29 shared publicationsKeiichi Ito
Gastroenterology, Mie Prefectural Shima Hospital, Shima, Japan
23 shared publicationsKatsumi Mukai
Department of Gastroenterology Suzuka General Hospital Suzuka Japan
18 shared publicationsTaishi Temma
Department of Gastroenterology, Ise Red Cross Hospital, Ise, Japan
13 shared publications
Latest Publications
- 12 May 2026
- Published by Wiley in Digestive Endoscopy
- Vol. 38 (5) , e70167
Nonexposed Muscular Layer Clipping Within a Submucosal Pocket Using a 20‐mm Reopenable Clip for Gastric Endoscopic Muscular Dissection
- 12 May 2026
- Published by Wiley in Digestive Endoscopy
- Vol. 38 (5) , e70167
Nonexposed Muscular Layer Clipping Within a Submucosal Pocket Using a 20‐mm Reopenable Clip for Gastric Endoscopic Muscular Dissection
- Open Access
- 2 April 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 02) , E576-E577
Next-generation reopenable-clip over-the-line method for gastric defects after endoscopic submucosal dissection at an anastomotic site
Various endoscopic techniques have been developed for defecting closure following gastric endoscopic submucosal dissection (ESD) for early gastric cancer [1]. We previously proposed the reopenable-clip over-the-line method (ROLM), which achieves defect closure by utilizing friction generated between a line (PE line: Super X-wire 1.5, DUEL Co.), the teeth of reopenable clips, and grasped tissue [2] [3]. Recently, a novel reopenable clip equipped with small anti-slip protrusions (Lockado clip, 11 mm; Micro-Tech Co. Ltd, Nanjing, China) has been introduced to enable stronger tissue fixation [4]. Here, we report a case in which next-generation ROLM using a Lockado clip was successfully applied for closure of a post-ESD gastric defect at an anastomotic site, which is considered technically challenging. A man in his 70s was diagnosed with early gastric cancer located on the anastomotic line at the lesser curvature of the upper gastric body after distal gastrectomy. We performed en bloc resection using ESD ([Fig. 1] and [Video 1]). The resulting mucosal defect measured approximately 50 mm and extended along the entire anastomotic line, making short-axis closure difficult. Therefore, double-layered suturing using the reopenable-clip over-the-line method was initially performed to reduce the defect along the short axis [5]. The defect was then closed using next-generation ROLM. First, a clip with a line was placed on the anal side of the defect to grasp both the mucosal and muscular layers. Additional reopenable clips with a line threaded through one tooth were sequentially applied to grasp the mucosal and muscular layers at the edges of the defect. By pulling the line while maintaining firm tissue grasp, the defect edges were approximated and strongly fixed through enhanced friction between the line, the small clip holes, and the anti-slip protrusions. Repetition of this maneuver enabled the complete closure of the defect on the anastomotic site without burying the muscle-grasping clips. The patient was discharged without adverse events. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 06 May 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 2 April 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 02) , E576-E577
Open AccessNext-generation reopenable-clip over-the-line method for gastric defects after endoscopic submucosal dissection at an anastomotic site
Various endoscopic techniques have been developed for defecting closure following gastric endoscopic submucosal dissection (ESD) for early gastric cancer [1]. We previously proposed the reopenable-clip over-the-line method (ROLM), which achieves defect closure by utilizing friction generated between a line (PE line: Super X-wire 1.5, DUEL Co.), the teeth of reopenable clips, and grasped tissue [2] [3]. Recently, a novel reopenable clip equipped with small anti-slip protrusions (Lockado clip, 11 mm; Micro-Tech Co. Ltd, Nanjing, China) has been introduced to enable stronger tissue fixation [4]. Here, we report a case in which next-generation ROLM using a Lockado clip was successfully applied for closure of a post-ESD gastric defect at an anastomotic site, which is considered technically challenging. A man in his 70s was diagnosed with early gastric cancer located on the anastomotic line at the lesser curvature of the upper gastric body after distal gastrectomy. We performed en bloc resection using ESD ([Fig. 1] and [Video 1]). The resulting mucosal defect measured approximately 50 mm and extended along the entire anastomotic line, making short-axis closure difficult. Therefore, double-layered suturing using the reopenable-clip over-the-line method was initially performed to reduce the defect along the short axis [5]. The defect was then closed using next-generation ROLM. First, a clip with a line was placed on the anal side of the defect to grasp both the mucosal and muscular layers. Additional reopenable clips with a line threaded through one tooth were sequentially applied to grasp the mucosal and muscular layers at the edges of the defect. By pulling the line while maintaining firm tissue grasp, the defect edges were approximated and strongly fixed through enhanced friction between the line, the small clip holes, and the anti-slip protrusions. Repetition of this maneuver enabled the complete closure of the defect on the anastomotic site without burying the muscle-grasping clips. The patient was discharged without adverse events. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 06 May 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 8 January 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 01) , E38-E39
Underwater internal traction-assisted reopenable clip-over-the-line method for full-thickness defect closure in a gastric collapse
We previously described a full-thickness defect closure technique using a line and reopenable clips [1]. However, complete closure of large defects in a collapsed stomach remains difficult. Recently, internal traction-assisted closure methods have been proposed to overcome this challenge [2]. Here, we report the first case of gastric full-thickness defect closure using an internal traction-assisted reopenable clip-over-the-line method (IT-ROLM) performed underwater. The patient had a 20-mm gastrointestinal stromal tumor in the upper gastric body ([Fig. 1], [Video 1]). Therefore, we performed endoscopic full-thickness resection under laparoscopic assistance. First, two channels were used to control bleeding with dual-channel rapid hemostasis, and the mucosa and the muscle layer were incised [3]. After confirming that the subserosal tissue had been reached, a reopenable clip over the line traction was applied [4]. Strong traction was then applied to the tumor, and it was resected in approximately 25 minutes. The defect was completely closed using IT-ROLM. Initially, the first clip with line was fixed to the normal mucosa on the anal side of the defect. Another clip, with the line passed through one tooth, was placed on the greater curvature, providing traction toward the anal side (IT-ROLM). When minimal gas insufflation was used for visualization, the gastric wall expanded; therefore, the stomach was carefully deaerated to create a low-pressure environment and then immersed in saline. The seal was maintained using a gas-free immersion system, which permits the infusion of small volumes of water into the hood [5]. It subsequently became easy to place clips at the edges of the defect under traction with the stomach deaerated. ROLM was repeated, and the defect was completely closed. The patient was discharged without adverse events. Underwater IT-ROLM is a feasible and effective technique for closing large gastric full-thickness defects, particularly in a collapsed stomach. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 08 January 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 8 January 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 01) , E38-E39
Open AccessUnderwater internal traction-assisted reopenable clip-over-the-line method for full-thickness defect closure in a gastric collapse
We previously described a full-thickness defect closure technique using a line and reopenable clips [1]. However, complete closure of large defects in a collapsed stomach remains difficult. Recently, internal traction-assisted closure methods have been proposed to overcome this challenge [2]. Here, we report the first case of gastric full-thickness defect closure using an internal traction-assisted reopenable clip-over-the-line method (IT-ROLM) performed underwater. The patient had a 20-mm gastrointestinal stromal tumor in the upper gastric body ([Fig. 1], [Video 1]). Therefore, we performed endoscopic full-thickness resection under laparoscopic assistance. First, two channels were used to control bleeding with dual-channel rapid hemostasis, and the mucosa and the muscle layer were incised [3]. After confirming that the subserosal tissue had been reached, a reopenable clip over the line traction was applied [4]. Strong traction was then applied to the tumor, and it was resected in approximately 25 minutes. The defect was completely closed using IT-ROLM. Initially, the first clip with line was fixed to the normal mucosa on the anal side of the defect. Another clip, with the line passed through one tooth, was placed on the greater curvature, providing traction toward the anal side (IT-ROLM). When minimal gas insufflation was used for visualization, the gastric wall expanded; therefore, the stomach was carefully deaerated to create a low-pressure environment and then immersed in saline. The seal was maintained using a gas-free immersion system, which permits the infusion of small volumes of water into the hood [5]. It subsequently became easy to place clips at the edges of the defect under traction with the stomach deaerated. ROLM was repeated, and the defect was completely closed. The patient was discharged without adverse events. Underwater IT-ROLM is a feasible and effective technique for closing large gastric full-thickness defects, particularly in a collapsed stomach. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 08 January 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 14 September 2025
- Published by Wiley in Digestive Endoscopy
- Vol. 38 (1)
Novel Saline‐Immersion Endoscopic Hemostasis With Flow‐Assisted Coagulation Using Gas‐Free Immersion System
Watch a video of this article.
- 14 September 2025
- Published by Wiley in Digestive Endoscopy
- Vol. 38 (1)
Novel Saline‐Immersion Endoscopic Hemostasis With Flow‐Assisted Coagulation Using Gas‐Free Immersion System
Watch a video of this article.
- 20 January 2025
- Published by Wiley in Digestive Endoscopy
- Vol. 37 (5) , 558-559
Closure method to prevent leakages from perforations using multiple over‐the‐scope clips in an over‐the‐line method
Watch a video of this article.
- 20 January 2025
- Published by Wiley in Digestive Endoscopy
- Vol. 37 (5) , 558-559
Closure method to prevent leakages from perforations using multiple over‐the‐scope clips in an over‐the‐line method
Watch a video of this article.
- Open Access
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E1381-E1382
Double-layered suturing using a reopenable-clip over-the-line method with a 20-mm reopenable clip to close a large gastric mucosal defect
Closing large defects left after endoscopic submucosal dissection (ESD) of the upper gastric body is difficult because of the thick muscle layer. We recently developed the reopenable-clip over-the-line method (ROLM) to assist such closure procedures [1] [2] [3]. Furthermore, a 20-mm reopenable clip (LOCKADO clip; 20 mm; Micro-Tech (Nanjing) Co., Ltd, Nanjing, China) with a large opening width has recently become available in Japan [4]. We have now also explored a double-layered ROLM (DL-ROLM) approach that achieves complete closure using a large clip combined with double-layered suturing ([Fig. 1]). The wide, reopenable clip features small protrusions to prevent slippage, allowing it to grab more tissue than conventional clips. Its reopenable function facilitates substantial muscle grasping. We recently treated a patient with a large post-ESD defect left in the stomach’s upper lesser curvature ([Fig. 2] and [Video 1]). Because of significant muscle layer damage we observed during the ESD, we closed the defect entirely, using DL-ROLM. We grasped a large portion of the muscle on the floor of the ulcer and placed the reopenable clip [5]. A second clip was then placed to grasp the folds created by the initial clip, as well as the musculature on the ulcer floor. Additional clips were placed similarly to grasp the regional muscles. Together, the clips held the defect in an oval shape, facilitating further closure using the ROLM approach. Threaded clips were then placed along the edges of the defect. The clips with lines threaded through their teeth were placed on the contralateral edge of the defect. We confirmed endoscopically that the clip had not been buried. The repeated placement of clips with lines threaded through the tooth was then able to completely close the large defect, and the patient was discharged without any adverse events. By folding the muscle over a large mucosal defect, DL-ROLM facilitates ROLM and a more secure closure, potentially extending the duration over which closure is maintained. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 28 November 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E1381-E1382
Open AccessDouble-layered suturing using a reopenable-clip over-the-line method with a 20-mm reopenable clip to close a large gastric mucosal defect
Closing large defects left after endoscopic submucosal dissection (ESD) of the upper gastric body is difficult because of the thick muscle layer. We recently developed the reopenable-clip over-the-line method (ROLM) to assist such closure procedures [1] [2] [3]. Furthermore, a 20-mm reopenable clip (LOCKADO clip; 20 mm; Micro-Tech (Nanjing) Co., Ltd, Nanjing, China) with a large opening width has recently become available in Japan [4]. We have now also explored a double-layered ROLM (DL-ROLM) approach that achieves complete closure using a large clip combined with double-layered suturing ([Fig. 1]). The wide, reopenable clip features small protrusions to prevent slippage, allowing it to grab more tissue than conventional clips. Its reopenable function facilitates substantial muscle grasping. We recently treated a patient with a large post-ESD defect left in the stomach’s upper lesser curvature ([Fig. 2] and [Video 1]). Because of significant muscle layer damage we observed during the ESD, we closed the defect entirely, using DL-ROLM. We grasped a large portion of the muscle on the floor of the ulcer and placed the reopenable clip [5]. A second clip was then placed to grasp the folds created by the initial clip, as well as the musculature on the ulcer floor. Additional clips were placed similarly to grasp the regional muscles. Together, the clips held the defect in an oval shape, facilitating further closure using the ROLM approach. Threaded clips were then placed along the edges of the defect. The clips with lines threaded through their teeth were placed on the contralateral edge of the defect. We confirmed endoscopically that the clip had not been buried. The repeated placement of clips with lines threaded through the tooth was then able to completely close the large defect, and the patient was discharged without any adverse events. By folding the muscle over a large mucosal defect, DL-ROLM facilitates ROLM and a more secure closure, potentially extending the duration over which closure is maintained. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 28 November 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E1151-E1152
Duodenal endoscopic submucosal dissection using dual-channel rapid hemostasis for a large tumor involving the papilla
Duodenal endoscopic submucosal dissection (ESD) is a challenging procedure for large tumors involving the papilla [1]. We previously reported a dual-channel rapid hemostasis (RH) technique using a gas-free immersion (GFI) system that effectively stopped bleeding during gastric ESD with saline immersion [2] [3]. This method involves performing ESD using a double-channel endoscope (GIF-2TQ260M; Olympus), with hemostatic forceps pre-inserted into one of the accessory channels. Here, we present a case of a large duodenal tumor involving the papilla, in which ESD was performed using this method. The patient had a 50-mm duodenal tumor in the papilla. En bloc resection was performed using saline-immersion ESD with RH and the GFI system ([Fig. 1], [Video 1]). First, a calibrated, small-caliber tip, transparent hood (CAST hood; TOP, Tokyo, Japan) with a 4-mm tapered tip was attached to the scope [4]. Hemostatic forceps were preinserted into one of the accessory channels. After insertion of the scope, a hyaluronic acid solution was locally injected into the submucosal layer, and a mucosal incision was made at a distance from the tumor. The papilla was intentionally preserved, and an incision was made directly above the muscle layer to separate the bile and pancreatic ducts. A large blood vessel was observed on the anal side of the papilla and was pre-sealed with hemostatic forceps. When active bleeding occurred during submucosal dissection, hemostasis was easily achieved by bringing the hemostatic forceps close to the bleeding point and closing them. Flow-assisted coagulation using GFI enabled non-contact hemostasis under saline immersion by positioning the forceps near the bleeding point and coagulating the tissue. Using these techniques, the tumor was resected in 43 minutes. The remaining mucosal defect measured 60 mm; therefore, endoscopic biliary and pancreatic drainage tubes were inserted, and the defect was completely closed using the reopenable clip over the line method [5]. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AD Article published online: 13 October 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E1151-E1152
Open AccessDuodenal endoscopic submucosal dissection using dual-channel rapid hemostasis for a large tumor involving the papilla
Duodenal endoscopic submucosal dissection (ESD) is a challenging procedure for large tumors involving the papilla [1]. We previously reported a dual-channel rapid hemostasis (RH) technique using a gas-free immersion (GFI) system that effectively stopped bleeding during gastric ESD with saline immersion [2] [3]. This method involves performing ESD using a double-channel endoscope (GIF-2TQ260M; Olympus), with hemostatic forceps pre-inserted into one of the accessory channels. Here, we present a case of a large duodenal tumor involving the papilla, in which ESD was performed using this method. The patient had a 50-mm duodenal tumor in the papilla. En bloc resection was performed using saline-immersion ESD with RH and the GFI system ([Fig. 1], [Video 1]). First, a calibrated, small-caliber tip, transparent hood (CAST hood; TOP, Tokyo, Japan) with a 4-mm tapered tip was attached to the scope [4]. Hemostatic forceps were preinserted into one of the accessory channels. After insertion of the scope, a hyaluronic acid solution was locally injected into the submucosal layer, and a mucosal incision was made at a distance from the tumor. The papilla was intentionally preserved, and an incision was made directly above the muscle layer to separate the bile and pancreatic ducts. A large blood vessel was observed on the anal side of the papilla and was pre-sealed with hemostatic forceps. When active bleeding occurred during submucosal dissection, hemostasis was easily achieved by bringing the hemostatic forceps close to the bleeding point and closing them. Flow-assisted coagulation using GFI enabled non-contact hemostasis under saline immersion by positioning the forceps near the bleeding point and coagulating the tissue. Using these techniques, the tumor was resected in 43 minutes. The remaining mucosal defect measured 60 mm; therefore, endoscopic biliary and pancreatic drainage tubes were inserted, and the defect was completely closed using the reopenable clip over the line method [5]. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AD Article published online: 13 October 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E837-E838
A novel traction method for underwater colorectal endoscopic submucosal dissection: reopenable clip-over-the-line traction
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E837-E838
Open AccessA novel traction method for underwater colorectal endoscopic submucosal dissection: reopenable clip-over-the-line traction
- Open Access
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E736-E737
Defect closure after duodenal endoscopic submucosal dissection for a tumor of the minor papilla in a patient with pancreas divisum: reopenable-clip over-the-line method
Closure of large duodenal endoscopic submucosal dissection (ESD) defects that include the entire minor papilla are extremely difficult because the duodenal muscle layer on the pancreatic side is relatively hard and difficult to maneuver [1]. We overcame these difficulties by devising a method called the reopenable-clip over-the-line method (ROLM), which facilitates the closure of large defects even in narrow lumens [2] [3]. Herein, we present a case of defect closure after duodenal ESD for a minor papillary tumor with pancreatic divisum using the ROLM. The patient in this case had early duodenal cancer ([Fig. 1], [Video 1]). The lesion was approximately 40 mm in size and covered the entire minor papilla. Magnetic resonance cholangiopancreatography revealed partial pancreas divisum; therefore, it was considered important to avoid obstructing the flow of pancreatic juice from the accessory pancreatic duct. En bloc resection of the tumor was initially performed using ESD. In the expectation of bleeding due to the large size of the tumor, dual-channel rapid hemostasis was performed using a gas-free immersion system, and the procedure was performed with saline immersion [4]. Following resection, the defect measured approximately 50 mm, with the opening of the accessory pancreatic duct located at the defect edge. A duodenoscope was used to place the pancreatic duct stent in the duodenum. Finally, defect closure was performed using the ROLM, ensuring that the pancreatic duct stent was not embedded in the ulcer floor by securing the closure with clips. Using a 4-mm tapered hood, the pancreatic duct stent was positioned on the side of the duodenal lumen, without embedding it into the ulcer floor, and the defect edge on the opposite side was grasped with the clip [5]. Repeated ROLM was performed to completely close the defects. The patient was discharged without adverse events. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AD Article published online: 10 July 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E736-E737
Open AccessDefect closure after duodenal endoscopic submucosal dissection for a tumor of the minor papilla in a patient with pancreas divisum: reopenable-clip over-the-line method
Closure of large duodenal endoscopic submucosal dissection (ESD) defects that include the entire minor papilla are extremely difficult because the duodenal muscle layer on the pancreatic side is relatively hard and difficult to maneuver [1]. We overcame these difficulties by devising a method called the reopenable-clip over-the-line method (ROLM), which facilitates the closure of large defects even in narrow lumens [2] [3]. Herein, we present a case of defect closure after duodenal ESD for a minor papillary tumor with pancreatic divisum using the ROLM. The patient in this case had early duodenal cancer ([Fig. 1], [Video 1]). The lesion was approximately 40 mm in size and covered the entire minor papilla. Magnetic resonance cholangiopancreatography revealed partial pancreas divisum; therefore, it was considered important to avoid obstructing the flow of pancreatic juice from the accessory pancreatic duct. En bloc resection of the tumor was initially performed using ESD. In the expectation of bleeding due to the large size of the tumor, dual-channel rapid hemostasis was performed using a gas-free immersion system, and the procedure was performed with saline immersion [4]. Following resection, the defect measured approximately 50 mm, with the opening of the accessory pancreatic duct located at the defect edge. A duodenoscope was used to place the pancreatic duct stent in the duodenum. Finally, defect closure was performed using the ROLM, ensuring that the pancreatic duct stent was not embedded in the ulcer floor by securing the closure with clips. Using a 4-mm tapered hood, the pancreatic duct stent was positioned on the side of the duodenal lumen, without embedding it into the ulcer floor, and the defect edge on the opposite side was grasped with the clip [5]. Repeated ROLM was performed to completely close the defects. The patient was discharged without adverse events. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AD Article published online: 10 July 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany