Simulation of Scalar-Mode Optically Pumped Magnetometers to Search Optimal Operating Conditions
Authors:
Open Access
- 1 June 2024
- journal article
- research article
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Electronics
- Vol. E107.C (6) , 164-170
Abstract
In recent years, measuring biomagnetic fields in the Earth's field by differential measurements of scalar-mode OPMs have been actively attempted. In this study, the sensitivity of the scalar-mode OPMs under the geomagnetic environment in the laboratory was studied by numerical simulation. Although the noise level of the scalar-mode OPM in the laboratory environment was calculated to be \SI[per-mode=symbol]{104}{\pico\tesla\per\sqrt{\hertz}}, the noise levels using the first-order and the second-order differential configurations were found to be \SI[per-mode=symbol]{529}{\femto\tesla\per\centi\metre\per\sqrt{\hertz}} and \SI[per-mode=symbol]{17.2}{\femto\tesla\per\centi\metre^2\per\sqrt{\hertz}}, respectively. This result indicated that scalar-mode OPMs can measure very weak magnetic fields such as MEG without high-performance magnetic shield roomns. We also studied the operating conditions by varying repetition frequency and temperature. We found that scalar-mode OPMs have an upper limit of repetition frequency and temperature, and that the repetition frequency should be set below 4 kHz and the temperature should be set below 120 °C.Keywords
This publication has 13 references indexed in Scilit:
- Portable Magnetometry for Detection of Biomagnetism in Ambient EnvironmentsPhysical Review Applied, 2020
- Portable intrinsic gradiometer for ultra-sensitive detection of magnetic gradient in unshielded environmentApplied Physics Letters, 2020
- Temperature characteristics of K-Rb hybrid optically pumped magnetometers with different density ratiosOptics Express, 2019
- Multi-channel atomic magnetometer for magnetoencephalography: A configuration studyNeuroImage, 2014
- Subfemtotesla Scalar Atomic Magnetometry Using Multipass CellsPhysical Review Letters, 2013
- Highly Sensitive and Easy-to-Use SQUID SensorsIEEE Transactions on Applied Superconductivity, 2007
- Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometerApplied Physics Letters, 2004
- A subfemtotesla multichannel atomic magnetometerNature, 2003
- High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange RelaxationPhysical Review Letters, 2002
- Theory of spin-exchange optical pumping ofandPhysical Review A, 1998