Yosuke Ito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yosuke Ito has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
Tetsuo Kobayashi
Department of Electrical Engineering, Graduate School of Engineering, Kyoto University, Kyoto-Daigaku-Katsura, Nishikyo-ku, Kyoto, 615-8510, Japan
11 shared publicationsKeigo Kamada
Department of Electrical Engineering, Graduate School of Engineering, Kyoto University, Kyoto-Daigaku-Katsura, Nishikyo-Ku, Kyoto 615-8510, Japan
8 shared publicationsKunihide Tachibana
Graduate School of Engineering, Kyoto University, Kyoto‐Daigaku‐Katsura, Nishikyo‐ku, Kyoto 615‐8510, Japan
7 shared publicationsHiroyuki Ohnishi
Department of Electrical Engineering, Kyoto University, KyotoDaigakuKatsura, Nishikyo-ku, 615-8510, Japan
4 shared publications- Keiichiro Urabe
Kyoto University, Kyoto, Japan
4 shared publications Osamu Sakai
Department of Electronic Science and Engineering, Kyoto University, Kyoto-Daigaku-Katsura, Nishikyo-ku, Kyoto 615-8510, Japan
4 shared publications
Latest Publications
- 13 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (15)
Simulation study of low-field proton magnetic resonance spectroscopy using optically pumped magnetometers
We numerically investigated the feasibility of low-field magnetic resonance spectroscopy (MRS) using optically pumped magnetometers (OPMs). Low magnetic fields reduce signal strength and spectral resolution, challenging reliable metabolite quantification. To address these issues, we performed Bloch-equation–based simulations at 0.01–7 T using aqueous phantoms. We compared chemical shift selective and inversion recovery (IR) methods for water suppression. We also evaluated signal detection using both radio frequency coils and OPMs. The IR method, relying on T1 contrast rather than frequency selectivity, effectively suppressed water signals down to 0.1 T. The signal-to-noise ratio (SNR) of Glu increased below 0.7 T. OPMs maintained nearly constant SNR across 0.01–1 T and outperformed coils below 1 T. In mixed-metabolite settings, however, spectral overlap and IR-induced co-suppression impaired detection—particularly for Gln below 0.1 T. These results show that IR and OPMs offer complementary advantages for low-field MRS, while spectral resolution remains a challenge. This work provides a theoretical basis for enhancing low-field MRS techniques and expanding access to metabolic diagnostics in clinical and research settings.
- 13 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (15)
Simulation study of low-field proton magnetic resonance spectroscopy using optically pumped magnetometers
We numerically investigated the feasibility of low-field magnetic resonance spectroscopy (MRS) using optically pumped magnetometers (OPMs). Low magnetic fields reduce signal strength and spectral resolution, challenging reliable metabolite quantification. To address these issues, we performed Bloch-equation–based simulations at 0.01–7 T using aqueous phantoms. We compared chemical shift selective and inversion recovery (IR) methods for water suppression. We also evaluated signal detection using both radio frequency coils and OPMs. The IR method, relying on T1 contrast rather than frequency selectivity, effectively suppressed water signals down to 0.1 T. The signal-to-noise ratio (SNR) of Glu increased below 0.7 T. OPMs maintained nearly constant SNR across 0.01–1 T and outperformed coils below 1 T. In mixed-metabolite settings, however, spectral overlap and IR-induced co-suppression impaired detection—particularly for Gln below 0.1 T. These results show that IR and OPMs offer complementary advantages for low-field MRS, while spectral resolution remains a challenge. This work provides a theoretical basis for enhancing low-field MRS techniques and expanding access to metabolic diagnostics in clinical and research settings.
- Open Access
- 28 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-15
Simplified shielded MEG-MRI multimodal system with scalar-mode optically pumped magnetometers as MEG sensors
Magnetoencephalography (MEG) conventionally operates within high-performance magnetic shields due to the extremely weak magnetic field signals from the measured objects and the narrow dynamic range of the magnetic sensors employed for detection. This limitation results in elevated equipment costs and restricted usage. Additionally, the information obtained from MEG is functional images, and to analyze from which part of the brain the signals are coming, it is necessary to capture morphological images separately. When MEG and morphological imaging devices are separate, despite their individual high measurement accuracies, discrepancies in positional information may arise. In response, we have developed a low-field magnetic resonance imaging system that incorporates scalar-mode optically pumped magnetometers with a wide dynamic range and exceptionally high measurement sensitivity as sensors for MEG. Operating at low magnetic fields eliminates the need for superconducting coils in magnetic resonance imaging and the high-performance magnetic shields essential for MEG, promising a substantial cost reduction compared to traditional approaches. We achieved a noise level of about $${16.7}\,\hbox {pT/Hz}^{1/2}$$ with a single channel magnetometer, and reached a noise level of $${367}\,\hbox {fT/cm/Hz}^{1/2}$$ with a baseline of 1 cm through differential measurements. We employed this system to conduct sequential OPM-based magnetic field measurements and MRI imaging, successfully demonstrating the compatibility of high OPM sensitivity with clear MRI acquisition.- 28 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-15
Open AccessSimplified shielded MEG-MRI multimodal system with scalar-mode optically pumped magnetometers as MEG sensors
Magnetoencephalography (MEG) conventionally operates within high-performance magnetic shields due to the extremely weak magnetic field signals from the measured objects and the narrow dynamic range of the magnetic sensors employed for detection. This limitation results in elevated equipment costs and restricted usage. Additionally, the information obtained from MEG is functional images, and to analyze from which part of the brain the signals are coming, it is necessary to capture morphological images separately. When MEG and morphological imaging devices are separate, despite their individual high measurement accuracies, discrepancies in positional information may arise. In response, we have developed a low-field magnetic resonance imaging system that incorporates scalar-mode optically pumped magnetometers with a wide dynamic range and exceptionally high measurement sensitivity as sensors for MEG. Operating at low magnetic fields eliminates the need for superconducting coils in magnetic resonance imaging and the high-performance magnetic shields essential for MEG, promising a substantial cost reduction compared to traditional approaches. We achieved a noise level of about $${16.7}\,\hbox {pT/Hz}^{1/2}$$ with a single channel magnetometer, and reached a noise level of $${367}\,\hbox {fT/cm/Hz}^{1/2}$$ with a baseline of 1 cm through differential measurements. We employed this system to conduct sequential OPM-based magnetic field measurements and MRI imaging, successfully demonstrating the compatibility of high OPM sensitivity with clear MRI acquisition. - Open Access
- 1 June 2024
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Electronics
- Vol. E107.C (6) , 164-170
Simulation of Scalar-Mode Optically Pumped Magnetometers to Search Optimal Operating Conditions
In recent years, measuring biomagnetic fields in the Earth's field by differential measurements of scalar-mode OPMs have been actively attempted. In this study, the sensitivity of the scalar-mode OPMs under the geomagnetic environment in the laboratory was studied by numerical simulation. Although the noise level of the scalar-mode OPM in the laboratory environment was calculated to be \SI[per-mode=symbol]{104}{\pico\tesla\per\sqrt{\hertz}}, the noise levels using the first-order and the second-order differential configurations were found to be \SI[per-mode=symbol]{529}{\femto\tesla\per\centi\metre\per\sqrt{\hertz}} and \SI[per-mode=symbol]{17.2}{\femto\tesla\per\centi\metre^2\per\sqrt{\hertz}}, respectively. This result indicated that scalar-mode OPMs can measure very weak magnetic fields such as MEG without high-performance magnetic shield roomns. We also studied the operating conditions by varying repetition frequency and temperature. We found that scalar-mode OPMs have an upper limit of repetition frequency and temperature, and that the repetition frequency should be set below 4 kHz and the temperature should be set below 120 °C.
- 1 June 2024
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Electronics
- Vol. E107.C (6) , 164-170
Open AccessSimulation of Scalar-Mode Optically Pumped Magnetometers to Search Optimal Operating Conditions
In recent years, measuring biomagnetic fields in the Earth's field by differential measurements of scalar-mode OPMs have been actively attempted. In this study, the sensitivity of the scalar-mode OPMs under the geomagnetic environment in the laboratory was studied by numerical simulation. Although the noise level of the scalar-mode OPM in the laboratory environment was calculated to be \SI[per-mode=symbol]{104}{\pico\tesla\per\sqrt{\hertz}}, the noise levels using the first-order and the second-order differential configurations were found to be \SI[per-mode=symbol]{529}{\femto\tesla\per\centi\metre\per\sqrt{\hertz}} and \SI[per-mode=symbol]{17.2}{\femto\tesla\per\centi\metre^2\per\sqrt{\hertz}}, respectively. This result indicated that scalar-mode OPMs can measure very weak magnetic fields such as MEG without high-performance magnetic shield roomns. We also studied the operating conditions by varying repetition frequency and temperature. We found that scalar-mode OPMs have an upper limit of repetition frequency and temperature, and that the repetition frequency should be set below 4 kHz and the temperature should be set below 120 °C.
- Open Access
Simplified Shielded MEG-MRI Multimodal System with Scalar-mode Optically Pumped Magnetometers as MEG Sensors
Magnetoencephalography (MEG) conventionally operates within high-performance magnetic shields due to the extremely weak magnetic field signals from the measured objects and the narrow dynamic range of the magnetic sensors employed for detection. This limitation results in elevated equipment costs and restricted usage. Additionally, the information obtained from MEG is functional images, and to analyze from which part of the brain the signals are coming, it is necessary to capture morphological images separately. When MEG and morphological imaging devices are separate, despite their individual high measurement accuracies, discrepancies in positional information may arise. In response, we have developed a low-field magnetic resonance imaging system that incorporates scalar-mode optically pumped magnetometers with a wide dynamic range and exceptionally high measurement sensitivity as sensors for MEG. Operating at low magnetic fields eliminates the need for superconducting coils in magnetic resonance imaging and the high-performance magnetic shields essential for MEG, promising a substantial cost reduction compared to traditional approaches. We achieved a noise level of about $16\,\rm{pT/Hz}^{1/2}$ with a single channel magnetometer, and reached a noise level of $367\,\rm{fT/cm/Hz}^{1/2}$ through differential measurements. The system successfully conducted MR imaging on a phantom, demonstrating the potential of MEG and MRI fusion.Open AccessSimplified Shielded MEG-MRI Multimodal System with Scalar-mode Optically Pumped Magnetometers as MEG Sensors
Magnetoencephalography (MEG) conventionally operates within high-performance magnetic shields due to the extremely weak magnetic field signals from the measured objects and the narrow dynamic range of the magnetic sensors employed for detection. This limitation results in elevated equipment costs and restricted usage. Additionally, the information obtained from MEG is functional images, and to analyze from which part of the brain the signals are coming, it is necessary to capture morphological images separately. When MEG and morphological imaging devices are separate, despite their individual high measurement accuracies, discrepancies in positional information may arise. In response, we have developed a low-field magnetic resonance imaging system that incorporates scalar-mode optically pumped magnetometers with a wide dynamic range and exceptionally high measurement sensitivity as sensors for MEG. Operating at low magnetic fields eliminates the need for superconducting coils in magnetic resonance imaging and the high-performance magnetic shields essential for MEG, promising a substantial cost reduction compared to traditional approaches. We achieved a noise level of about $16\,\rm{pT/Hz}^{1/2}$ with a single channel magnetometer, and reached a noise level of $367\,\rm{fT/cm/Hz}^{1/2}$ through differential measurements. The system successfully conducted MR imaging on a phantom, demonstrating the potential of MEG and MRI fusion. - 15 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 59 (11) , 1-5
Dynamics of Magnetization Under the Spin-Lock Pulse: General Solution of the Bloch Equation
Functional magnetic resonance imaging (fMRI) conventionally relies on hemodynamics response induced some seconds after neural activation. Therefore, the temporal limitations of fMRI is the main challenge and we focused on the spin-lock sequence, which identifies neural magnetic field using magnetic resonance between the spin-lock pulse and the measurement target. This potentially addresses limitations of the traditional fMRI such as low temporal resolution and high static magnetic field. To enhance spin-lock sequences, it is essential to analyze magnetization dynamics during the spin-lock pulse. This study improved our previous proposal by presenting the particular solution of the Bloch equation, which allows us to consider the effect of T 1 relaxation. We also confirmed the novel solution with the comparison of numerical simulations without any approximation and discovered that the solution improved accuracy for My and Mz . The offset errors for My and Mz became smaller than 1 × 10 -5 times to the thermal equilibrium magnetization and the magnitude of errors was reduced to 3.2975 × 10 -3 and 1.3072 × 10 -1 times compared to our previous proposal. This improvement contributes to acquisition-integrated spin-lock sequences. There are still drawbacks due to the rotating wave approximation in our new proposal, but, it is applicable when the frequency bandwidth of spin-lock resonance is narrow, or the measurement target, such as a steady-state induced response, can be approximated by a single-frequency sine wave.
- 15 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 59 (11) , 1-5
Dynamics of Magnetization Under the Spin-Lock Pulse: General Solution of the Bloch Equation
Functional magnetic resonance imaging (fMRI) conventionally relies on hemodynamics response induced some seconds after neural activation. Therefore, the temporal limitations of fMRI is the main challenge and we focused on the spin-lock sequence, which identifies neural magnetic field using magnetic resonance between the spin-lock pulse and the measurement target. This potentially addresses limitations of the traditional fMRI such as low temporal resolution and high static magnetic field. To enhance spin-lock sequences, it is essential to analyze magnetization dynamics during the spin-lock pulse. This study improved our previous proposal by presenting the particular solution of the Bloch equation, which allows us to consider the effect of T 1 relaxation. We also confirmed the novel solution with the comparison of numerical simulations without any approximation and discovered that the solution improved accuracy for My and Mz . The offset errors for My and Mz became smaller than 1 × 10 -5 times to the thermal equilibrium magnetization and the magnitude of errors was reduced to 3.2975 × 10 -3 and 1.3072 × 10 -1 times compared to our previous proposal. This improvement contributes to acquisition-integrated spin-lock sequences. There are still drawbacks due to the rotating wave approximation in our new proposal, but, it is applicable when the frequency bandwidth of spin-lock resonance is narrow, or the measurement target, such as a steady-state induced response, can be approximated by a single-frequency sine wave.
- Open Access
- 31 March 2021
- Published by Japan Cement Association in Cement Science and Concrete Technology
- Vol. 74 (1) , 118-124
THE EFFECT OF VIBRATION TIME OF THE MORTAR MIXED WITH ELECTRIC FURNACE OXIDIZING SLAGS, LIGHTWEIGHT FINE AGGREGATES AND STYROFOAM BEADS ON ELECTROMAGNETIC WAVE ABSORPTION PERFORMANCE
電波を使用する機器同士の干渉による通信障害を防ぐため、建築物の壁面等に広帯域電波吸収体の設置が求められる。そこで、一般建築物での大量使用に耐えうる安価で容易に作製できる電波吸収体を開発する。電気炉酸化スラグ、軽量細骨材または発泡スチロールビーズを骨材としたモルタルをテーブルバイブレータで加振して電波照射側から段階的に複素比誘電率及び複素比透磁率が変化する電波吸収体を作製する。これらモルタルの加振時間がモルタル内のスラグの分布や反射減衰量に及ぼす影響を検討し、電気炉酸化スラグと発泡スチロールビーズを用いたモルタルの加振で、十分な性能を有する広帯域電波吸収体を容易に作製できると示した。
- 31 March 2021
- Published by Japan Cement Association in Cement Science and Concrete Technology
- Vol. 74 (1) , 118-124
Open AccessTHE EFFECT OF VIBRATION TIME OF THE MORTAR MIXED WITH ELECTRIC FURNACE OXIDIZING SLAGS, LIGHTWEIGHT FINE AGGREGATES AND STYROFOAM BEADS ON ELECTROMAGNETIC WAVE ABSORPTION PERFORMANCE
電波を使用する機器同士の干渉による通信障害を防ぐため、建築物の壁面等に広帯域電波吸収体の設置が求められる。そこで、一般建築物での大量使用に耐えうる安価で容易に作製できる電波吸収体を開発する。電気炉酸化スラグ、軽量細骨材または発泡スチロールビーズを骨材としたモルタルをテーブルバイブレータで加振して電波照射側から段階的に複素比誘電率及び複素比透磁率が変化する電波吸収体を作製する。これらモルタルの加振時間がモルタル内のスラグの分布や反射減衰量に及ぼす影響を検討し、電気炉酸化スラグと発泡スチロールビーズを用いたモルタルの加振で、十分な性能を有する広帯域電波吸収体を容易に作製できると示した。
- Open Access
- 25 March 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Neural magnetic field dependent fMRI toward direct functional connectivity measurements: A phantom study
Recently, the main issue in neuroscience has been the imaging of the functional connectivity in the brain. No modality that can measure functional connectivity directly, however, has been developed yet. Here, we show the novel MRI sequence, called the partial spinlock sequence toward direct measurements of functional connectivity. This study investigates a probable measurement of phase differences directly associated with functional connectivity. By employing partial spinlock imaging, the neural magnetic field might influence the magnetic resonance signals. Using simulation and phantom studies to model the neural magnetic fields, we showed that magnetic resonance signals vary depending on the phase of an externally applied oscillating magnetic field with non-right flip angles. These results suggest that the partial spinlock sequence is a promising modality for functional connectivity measurements.
- 25 March 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Open AccessNeural magnetic field dependent fMRI toward direct functional connectivity measurements: A phantom study
Recently, the main issue in neuroscience has been the imaging of the functional connectivity in the brain. No modality that can measure functional connectivity directly, however, has been developed yet. Here, we show the novel MRI sequence, called the partial spinlock sequence toward direct measurements of functional connectivity. This study investigates a probable measurement of phase differences directly associated with functional connectivity. By employing partial spinlock imaging, the neural magnetic field might influence the magnetic resonance signals. Using simulation and phantom studies to model the neural magnetic fields, we showed that magnetic resonance signals vary depending on the phase of an externally applied oscillating magnetic field with non-right flip angles. These results suggest that the partial spinlock sequence is a promising modality for functional connectivity measurements.
- Open Access
- 18 January 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (2) , 1988-1996
High-sensitivity multi-channel probe beam detector towards MEG measurements of small animals with an optically pumped K-Rb hybrid magnetometer
Multi-channel measurements with fine spatial resolution will make magnetoencephalograms (MEGs) possible with small animals using optically pumped magnetometers (OPMs). Therefore, we fabricated a 20-channel probe-beam detector that uses a K-Rb hybrid OPM to increase the spatial resolution. First, we investigated the sensitivity of the detector using the multi-channel measurements and demonstrated that the detector had a fine sensitivity (10–20 fT/Hz1/2 at 10 Hz). Subsequently, we measured magnetic field distribution generated from a loop coil and compared those measurements with analytically calculated distributions. The measurements were in good agreement with the theoretical predictions. The experimental results indicate that our newly developed multi-channel OPM detector has sufficient performance specifications for MEG measurements.
- 18 January 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (2) , 1988-1996
Open AccessHigh-sensitivity multi-channel probe beam detector towards MEG measurements of small animals with an optically pumped K-Rb hybrid magnetometer
Multi-channel measurements with fine spatial resolution will make magnetoencephalograms (MEGs) possible with small animals using optically pumped magnetometers (OPMs). Therefore, we fabricated a 20-channel probe-beam detector that uses a K-Rb hybrid OPM to increase the spatial resolution. First, we investigated the sensitivity of the detector using the multi-channel measurements and demonstrated that the detector had a fine sensitivity (10–20 fT/Hz1/2 at 10 Hz). Subsequently, we measured magnetic field distribution generated from a loop coil and compared those measurements with analytically calculated distributions. The measurements were in good agreement with the theoretical predictions. The experimental results indicate that our newly developed multi-channel OPM detector has sufficient performance specifications for MEG measurements.
- Open Access
- 1 January 2017
- Published by Architectural Institute of Japan in Journal of Structural and Construction Engineering (Transactions of AIJ)
- Vol. 82 (739) , 1321-1327
EFFECT OF THICKNESS OF THE BASE LAYER ON ELECTROMAGNETIC ABSORPTION ON HEATING MORTAR BLOCKS FOR MELTING SNOW THROUGH QUASI MICROWAVES
- 1 January 2017
- Published by Architectural Institute of Japan in Journal of Structural and Construction Engineering (Transactions of AIJ)
- Vol. 82 (739) , 1321-1327
Open AccessEFFECT OF THICKNESS OF THE BASE LAYER ON ELECTROMAGNETIC ABSORPTION ON HEATING MORTAR BLOCKS FOR MELTING SNOW THROUGH QUASI MICROWAVES
- 1 January 2017
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 274, 89-94
Remote detected Low-Field MRI using an optically pumped atomic magnetometer combined with a liquid cooled pre-polarization coil
- 1 January 2017
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 274, 89-94
Remote detected Low-Field MRI using an optically pumped atomic magnetometer combined with a liquid cooled pre-polarization coil